39 research outputs found

    Consensus Panel on a Cochlear Coordinate System Applicable in Histologic, Physiologic, and Radiologic Studies of the Human Cochlea

    Get PDF
    Hypothesis—An objective cochlear framework, for evaluation of the cochlear anatomy and description of the position of an implanted cochlear implant electrode, would allow the direct comparison of measures performed within the various sub-disciplines involved in cochlear implant research. Background—Research on the human cochlear anatomy in relation to tonotopy and cochlear implantation is conducted by specialists from numerous disciplines such as histologists, surgeons, physicists, engineers, audiologists and radiologists. To allow accurate comparisons between and combinations of previous and forthcoming scientific and clinical studies, cochlear structures and electrode positions must be specified in a consistent manner. Methods—Researchers with backgrounds in the various fields of inner ear research as well as representatives of the different manufacturers of cochlear implants (Advanced Bionics Corp, Med-El, Cochlear Corp) were involved in consensus meetings held in Dallas, March 2005 and Asilomar, August 2005. Existing coordinate systems were evaluated and requisites for an objective cochlear framework were discussed. Results—The consensus panel agreed upon a 3-dimensional, cylindrical coordinate system of the cochlea using the “Cochlear View” as a basis and choosing a z-axis through the modiolus. The zero reference angle was chosen at the centre of the round window, which has a close relationship to the basal end of the Organ of Corti. Conclusions—Consensus was reached on an objective cochlear framework, allowing the outcomes of studies from different fields of research to be compared directly

    Новые книги

    Get PDF
    IMPORTANCE The cost of bilateral cochlear implantation (BCI) is usually not reimbursed by insurance companies because of a lack of well-designed studies reporting the benefits of a second cochlear implant. OBJECTIVE To determine the benefits of simultaneous BCI compared with unilateral cochlear implantation (UCI) in adults with postlingual deafness. DESIGN, SETTING, AND PARTICIPANTS A multicenter randomized clinical trial was performed. The study took place in 5 Dutch tertiary referral centers: the University Medical Centers of Utrecht, Maastricht, Groningen, Leiden, and Nijmegen. Forty patients eligible for cochlear implantation met the study criteria and were included from January 12, 2010, through November 2, 2012. The main inclusion criteria were postlingual onset of hearing loss, age of 18 to 70 years, duration of hearing loss of less than 20 years, and a marginal hearing aid benefit. Two participants withdrew from the study before implantation. Nineteen participants were randomized to undergo UCI and 19 to undergo BCI. INTERVENTIONS The BCI group received 2 cochlear implants during 1 surgery. The UCI group received 1 cochlear implant. MAIN OUTCOMES AND MEASURES The primary outcome was the Utrecht Sentence Test with Adaptive Randomized Roving levels (speech in noise, both presented from straight ahead). Secondary outcomes were consonant-vowel-consonant words in silence, speech-intelligibility test with spatially separated sources (speech in noise from different directions), sound localization, and quality of hearing questionnaires. Before any data were collected, the hypothesis was that the BCI group would perform better on the objective and subjective tests that concerned speech intelligibility in noise and spatial hearing. RESULTS Thirty-eight patients were included in the study. Fifteen patients in the BCI group used hearing aids before implantation compared with 19 in the UCI group. Otherwise, there were no significant differences between the groups' baseline characteristics. At 1-year follow-up, there were no significant differences between groups on the Utrecht Sentence Test with Adaptive Randomized Roving levels (9.1 dB, UCI group; 8.2 dB, BCI group; P = .39) or the consonant-vowel-consonant test (median percentage correct score 85.0% in the UCI group and 86.8% in the BCI group; P = .21). The BCI group performed significantly better than the UCI group when noise came from different directions (median speech reception threshold in noise, 14.4 dB, BCI group; 5.6 dB, BCI group; P <.001). The BCI group was better able to localize sounds (median correct score of 50.0% at 60 degrees, UCI group; 96.7%, BCI group; P CONCLUSIONS AND RELEVANCE This randomized clinical trial demonstrates a significant benefit of simultaneous BCI above UCI in daily listening situations for adults with postlingual deafness

    Pitch Comparisons between Electrical Stimulation of a Cochlear Implant and Acoustic Stimuli Presented to a Normal-hearing Contralateral Ear

    Get PDF
    Four cochlear implant users, having normal hearing in the unimplanted ear, compared the pitches of electrical and acoustic stimuli presented to the two ears. Comparisons were between 1,031-pps pulse trains and pure tones or between 12 and 25-pps electric pulse trains and bandpass-filtered acoustic pulse trains of the same rate. Three methods—pitch adjustment, constant stimuli, and interleaved adaptive procedures—were used. For all methods, we showed that the results can be strongly influenced by non-sensory biases arising from the range of acoustic stimuli presented, and proposed a series of checks that should be made to alert the experimenter to those biases. We then showed that the results of comparisons that survived these checks do not deviate consistently from the predictions of a widely-used cochlear frequency-to-place formula or of a computational cochlear model. We also demonstrate that substantial range effects occur with other widely used experimental methods, even for normal-hearing listeners

    Cochlear implant programming: a global survey on the state of the art

    Get PDF
    The programming of CIs is essential for good performance. However, no Good Clinical Practice guidelines exist. This paper reports on the results of an inventory of the current practice worldwide. A questionnaire was distributed to 47 CI centers. They follow 47600 recipients in 17 countries and 5 continents. The results were discussed during a debate. Sixty-two percent of the results were verified through individual interviews during the following months. Most centers (72%) participated in a cross-sectional study logging 5 consecutive fitting sessions in 5 different recipients. Data indicate that general practice starts with a single switch-on session, followed by three monthly sessions, three quarterly sessions, and then annual sessions, all containing one hour of programming and testing. The main focus lies on setting maximum and, to a lesser extent, minimum current levels per electrode. These levels are often determined on a few electrodes and then extrapolated. They are mainly based on subjective loudness perception by the CI user and, to a lesser extent, on pure tone and speech audiometry. Objective measures play a small role as indication of the global MAP profile. Other MAP parameters are rarely modified. Measurable targets are only defined for pure tone audiometry. Huge variation exists between centers on all aspects of the fitting practice

    25th annual computational neuroscience meeting: CNS-2016

    Get PDF
    The same neuron may play different functional roles in the neural circuits to which it belongs. For example, neurons in the Tritonia pedal ganglia may participate in variable phases of the swim motor rhythms [1]. While such neuronal functional variability is likely to play a major role the delivery of the functionality of neural systems, it is difficult to study it in most nervous systems. We work on the pyloric rhythm network of the crustacean stomatogastric ganglion (STG) [2]. Typically network models of the STG treat neurons of the same functional type as a single model neuron (e.g. PD neurons), assuming the same conductance parameters for these neurons and implying their synchronous firing [3, 4]. However, simultaneous recording of PD neurons shows differences between the timings of spikes of these neurons. This may indicate functional variability of these neurons. Here we modelled separately the two PD neurons of the STG in a multi-neuron model of the pyloric network. Our neuron models comply with known correlations between conductance parameters of ionic currents. Our results reproduce the experimental finding of increasing spike time distance between spikes originating from the two model PD neurons during their synchronised burst phase. The PD neuron with the larger calcium conductance generates its spikes before the other PD neuron. Larger potassium conductance values in the follower neuron imply longer delays between spikes, see Fig. 17.Neuromodulators change the conductance parameters of neurons and maintain the ratios of these parameters [5]. Our results show that such changes may shift the individual contribution of two PD neurons to the PD-phase of the pyloric rhythm altering their functionality within this rhythm. Our work paves the way towards an accessible experimental and computational framework for the analysis of the mechanisms and impact of functional variability of neurons within the neural circuits to which they belong

    An objective method to measure electrode independence in cochlear implant patients with a dual-masker forward masking technique

    No full text
    This study introduced a dual-masker forward masking technique and evaluated whether this objective method could measure electrode independency in a cochlear implant; more particularly, whether the optimal locations and number of active electrodes could be determined. This method further enabled the investigation of the efficacy of current steering, because the proposed recording method could also be described as applying a sequentially current steered masker. The paradigm requires 5 frames involving 2 maskers and 1 probe and is referred to as the Apple Core method (MP5-AC). For each recording, both the masker and probe amplitude were varied independently, producing 3-D eCAP plots that showed the eCAP amplitude for independent variations of masker and probe amplitudes. A simple quantitative model was developed to aid interpretation of the results. Theory and model were clinically tested in 14 patients. On the basis of the model, the multi-variate, color-coded plots could be subdivided into seven distinct regions, each depicting a unique relationship between the probe and the maskers. The model's predictions supported interpretation of the results, and indicated independence for the probe electrode contacts only at lower current levels and/or at greater inter-electrode separations. The clinical results revealed a lack of selectivity in the electrode array for stimulus levels larger than 600 microA. This suggests that sequential current steering is only capable of producing a single excitation area at higher current levels, or smaller electrode distances, without additional loudness correction being applied. Thus, the MP5-AC paradigm provided insight concerning the independence of electrodes and the efficacy of current steering in clinical patients. However, its current clinical applicability is limited because measurements were adequate only in anesthetized patient

    Prolonged Insertion Time Reduces Translocation Rate of a Precurved Electrode Array in Cochlear Implantation

    No full text
    Hypothesis: Insertion speed during cochlear implantation determines the risk of cochlear trauma. By slowing down insertion speed tactile feedback is improved. This is highly conducive to control the course of the electrode array along the cochlear contour and prevent translocation from the scala tympani to the scala vestibuli. Background: Limiting insertion trauma is a dedicated goal in cochlear implantation to maintain the most favorable situation for electrical stimulation of the remaining stimulable neural components of the cochlea. Surgical technique is one of the potential influencers on translocation behavior of the electrode array. Methods: The intrascalar position of 226 patients, all implanted with a precurved electrode array, aiming a mid-scalar position, was evaluated. One group (n = 113) represented implantation with an insertion time less than 25 seconds (fast insertion) and the other group (n = 113) was implanted in 25 or more seconds (slow insertion). A logistic regression analysis studied the effect of insertion speed on insertion trauma, controlled for surgical approach, cochlear size, and angular insertion depth. Furthermore, the effect of translocation on speech performance was evaluated using a linear mixed model. Results: The translocation rate within the fast and slow insertion groups were respectively 27 and 10%. A logistic regression analysis showed that the odds of dislocation increases by 2.527 times with a fast insertion, controlled for surgical approach, cochlear size, and angular insertion depth (95% CI = 1.135, 5.625). We failed to find a difference in speech recognition between patients with and without translocated electrode arrays. Conclusion: Slowing down insertion speed till 25 seconds or longer reduces the incidence of translocation.Disorders of the head and nec

    Reducing interaction in simultaneous paired stimulation with CI.

    No full text
    In this study simultaneous paired stimulation of electrodes in cochlear implants is investigated by psychophysical experiments in 8 post-lingually deaf subjects (and one extra subject who only participated in part of the experiments). Simultaneous and sequential monopolar stimulation modes are used as references and are compared to channel interaction compensation, partial tripolar stimulation and a novel sequential stimulation strategy named phased array compensation. Psychophysical experiments are performed to investigate both the loudness integration during paired stimulation at the main electrodes as well as the interaction with the electrode contact located halfway between the stimulating pair. The study shows that simultaneous monopolar stimulation has more loudness integration on the main electrodes and more interaction in between the electrodes than sequential stimulation. Channel interaction compensation works to reduce the loudness integration at the main electrodes, but does not reduce the interaction in between the electrodes caused by paired stimulation. Partial tripolar stimulation uses much more current to reach the needed loudness, but shows the same interaction in between the electrodes as sequential monopolar stimulation. In phased array compensation we have used the individual impedance matrix of each subject to calculate the current needed on each electrode to exactly match the stimulation voltage along the array to that of sequential stimulation. The results show that the interaction in between the electrodes is the same as monopolar stimulation. The strategy uses less current than partial tripolar stimulation, but more than monopolar stimulation. In conclusion, the paper shows that paired stimulation is possible if the interaction is compensated
    corecore