183 research outputs found

    Long-term safety and tolerability of apremilast in patients with psoriasis : Pooled safety analysis for ≥156 weeks from 2 phase 3, randomized, controlled trials (ESTEEM 1 and 2)

    Get PDF
    BACKGROUND: Randomized, controlled trials demonstrated efficacy and safety of apremilast for moderate-to-severe plaque psoriasis and psoriatic arthritis. OBJECTIVE: Assess long-term safety of oral apremilast in psoriasis patients. METHODS: Safety findings are reported for 0 to ≥156 weeks from the Efficacy and Safety Trial Evaluating the Effects of Apremilast in Psoriasis (ESTEEM) 1 and 2. RESULTS: The 0 to ≥156-week apremilast-exposure period included 1184 patients treated twice daily with apremilast 30 mg (1902.2 patient-years). During 0 to ≤52 weeks, the adverse events (AEs) that occurred in ≥5% of patients included diarrhea, nausea, upper respiratory tract infection, nasopharyngitis, tension headache, and headache. From 0 to ≥156 weeks, no new AEs (affecting ≥5% of the population) were reported. AEs, serious AEs, and study drug discontinuations caused by AEs did not increase with long-term exposure. During the 0 to ≥156-week period, the rates of major cardiac events (exposure-adjusted incidence rate [EAIR] 0.5/100 patient-years), malignancies (EAIR 1.2/100 patient-years), depression (EAIR 1.8/100 patient-years), or suicide attempts (EAIR 0.1/100 patient-years) did not increase in comparison with the rates found during the 0 to ≤52-week period. No serious opportunistic infections, reactivation of tuberculosis, or clinically meaningful effects on laboratory measurements were reported. Limitations: This study had a high dropout rate (21% of patients ongoing [156 weeks); most were 156weeks,nonewAEs(affecting1 56 weeks, no new AEs (affecting 5 % of the population) were reported. LIMITATIONS: This study had a high dropout rate (21% of patients ongoing >156 weeks); most were unrelated to safety concerns. CONCLUSIONS: Apremilast demonstrated an acceptable safety profile and was generally well tolerated for ≥156 weeks

    The Simons Observatory microwave SQUID multiplexing detector module design

    Full text link
    Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μ\mumux). Simons Observatory will use 49 modules containing 60,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95%95\% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 pA/Hz\mathrm{pA/\sqrt{Hz}}. This impacts the projected SO mapping speed by <8%< 8\%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.Comment: Accepted to The Astrophysical Journa

    A New DREADD Facilitates the Multiplexed Chemogenetic Interrogation of Behavior

    Get PDF
    DREADDs are chemogenetic tools widely used to remotely control cellular signaling, neuronal activity and behavior. Here we used a structure-based approach to develop a new Gi coupled DREADD using the kappa-opioid receptor as template (KORD) that is activated by the pharmacologically inert ligand salvinorin B (SALB). Activation of virally-expressed KORD in several neuronal contexts robustly attenuated neuronal activity and modified behaviors. Additionally, co-expression of the KORD and the Gq coupled M3-DREADD within the same neuronal population facilitated the sequential and bi-directional remote control of behavior. The availability of DREADDs activated by different ligands provides enhanced opportunities for investigating diverse physiological systems using multiplexed chemogenetic actuators

    Phase 3 trials of ixekizumab in moderate-to-severe plaque psoriasis

    Get PDF
    BACKGROUND Two phase 3 trials (UNCOVER-2 and UNCOVER-3) showed that at 12 weeks of treatment, ixekizumab, a monoclonal antibody against interleukin-17A, was superior to placebo and etanercept in the treatment of moderate-to-severe psoriasis. We report the 60-week data from the UNCOVER-2 and UNCOVER-3 trials, as well as 12-week and 60-week data from a third phase 3 trial, UNCOVER-1. METHODS We randomly assigned 1296 patients in the UNCOVER-1 trial, 1224 patients in the UNCOVER-2 trial, and 1346 patients in the UNCOVER-3 trial to receive subcutaneous injections of placebo (placebo group), 80 mg of ixekizumab every 2 weeks after a starting dose of 160 mg (2-wk dosing group), or 80 mg of ixekizumab every 4 weeks after a starting dose of 160 mg (4-wk dosing group). Additional cohorts in the UNCOVER-2 and UNCOVER-3 trials were randomly assigned to receive 50 mg of etanercept twice weekly. At week 12 in the UNCOVER-3 trial, the patients entered a long-term extension period during which they received 80 mg of ixekizumab every 4 weeks through week 60; at week 12 in the UNCOVER-1 and UNCOVER-2 trials, the patients who had a response to ixekizumab (defined as a static Physicians Global Assessment [sPGA] score of 0 [clear] or 1 [minimal psoriasis]) were randomly reassigned to receive placebo, 80 mg of ixekizumab every 4 weeks, or 80 mg of ixekizumab every 12 weeks through week 60. Coprimary end points were the percentage of patients who had a score on the sPGA of 0 or 1 and a 75% or greater reduction from baseline in Psoriasis Area and Severity Index (PASI 75) at week 12. RESULTS In the UNCOVER-1 trial, at week 12, the patients had better responses to ixekizumab than to placebo; in the 2-wk dosing group, 81.8% had an sPGA score of 0 or 1 and 89.1% had a PASI 75 response; in the 4-wk dosing group, the respective rates were 76.4% and 82.6%; and in the placebo group, the rates were 3.2% and 3.9% (P<0.001 for all comparisons of ixekizumab with placebo). In the UNCOVER-1 and UNCOVER-2 trials, among the patients who were randomly reassigned at week 12 to receive 80 mg of ixekizumab every 4 weeks, 80 mg of ixekizumab every 12 weeks, or placebo, an sPGA score of 0 or 1 was maintained by 73.8%, 39.0%, and 7.0% of the patients, respectively. Patients in the UNCOVER-3 trial received continuous treatment of ixekizumab from weeks 0 through 60, and at week 60, at least 73% had an sPGA score of 0 or 1 and at least 80% had a PASI 75 response. Adverse events reported during ixekizumab use included neutropenia, candidal infections, and inflammatory bowel disease. CONCLUSIONS In three phase 3 trials involving patients with psoriasis, ixekizumab was effective through 60 weeks of treatment. As with any treatment, the benefits need to be weighed against the risks of adverse events. The efficacy and safety of ixekizumab beyond 60 weeks of treatment are not yet known

    Assessing the Effectiveness of Tradable Landuse Rights for Biodiversity Conservation: An Application to Canada's Boreal Mixedwood Forest

    Full text link

    Whole-genome sequencing reveals host factors underlying critical COVID-19

    Get PDF
    Critical COVID-19 is caused by immune-mediated inflammatory lung injury. Host genetic variation influences the development of illness requiring critical care1 or hospitalization2–4 after infection with SARS-CoV-2. The GenOMICC (Genetics of Mortality in Critical Care) study enables the comparison of genomes from individuals who are critically ill with those of population controls to find underlying disease mechanisms. Here we use whole-genome sequencing in 7,491 critically ill individuals compared with 48,400 controls to discover and replicate 23 independent variants that significantly predispose to critical COVID-19. We identify 16 new independent associations, including variants within genes that are involved in interferon signalling (IL10RB and PLSCR1), leucocyte differentiation (BCL11A) and blood-type antigen secretor status (FUT2). Using transcriptome-wide association and colocalization to infer the effect of gene expression on disease severity, we find evidence that implicates multiple genes—including reduced expression of a membrane flippase (ATP11A), and increased expression of a mucin (MUC1)—in critical disease. Mendelian randomization provides evidence in support of causal roles for myeloid cell adhesion molecules (SELE, ICAM5 and CD209) and the coagulation factor F8, all of which are potentially druggable targets. Our results are broadly consistent with a multi-component model of COVID-19 pathophysiology, in which at least two distinct mechanisms can predispose to life-threatening disease: failure to control viral replication; or an enhanced tendency towards pulmonary inflammation and intravascular coagulation. We show that comparison between cases of critical illness and population controls is highly efficient for the detection of therapeutically relevant mechanisms of disease

    A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation

    Get PDF
    Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
    • …
    corecore