7 research outputs found

    Pharmaceutics

    Get PDF
    The purpose of this study is to evaluate the visual acuity (VA) gain profiles between patients with drug-naive diabetic macular edema (DME) treated by dexamethasone implant (DEX-implant) and assess the baseline anatomical and functional factors that could influence the response to the treatment in real-life conditions. A retrospective, multi-center observational study included 129 eyes with drug-naive DME treated by DEX-implant. The Median follow-up was 13 months. Two groups of VA gain trajectories were identified-Group A, with 71% (n = 96) of patients whose average VA gain was less than five letters and Group B, with 29% (n = 33) of patients with an average gain of 20 letters. The probability of belonging to Group B was significantly higher in patients with baseline VA \textbackslashtextless 37 letters (p = 0.001). Ellipsoid zone alterations (EZAs) or disorganization of retinal inner layers (DRILs) were associated with a lower final VA (53.0 letters versus 66.4, p = 0.002) but without a significant difference in VA gain (4.9 letters versus 6.8, p = 0.582). Despite a low baseline VA, this subgroup of patients tends to have greater visual gain, encouraging treatment with DEX-implant in such advanced-stage disease. However, some baseline anatomic parameters, such as the presence of EZAs or DRILs, negatively influenced final vision

    Prise en charge des corps étrangers intra-oculaires au centre hospitalier national d ophtalmologie des Quinze-Vingts

    No full text
    PARIS7-Xavier Bichat (751182101) / SudocSudocFranceF

    The Effect of Selective Laser Trabeculoplasty on Intraocular Pressure in Patients with Dexamethasone Intravitreal Implant-Induced Elevated Intraocular Pressure

    No full text
    International audienceIntroduction. To assess the safety and efficacy of selective laser trabeculoplasty (SLT) for ocular hypertension (OHT) induced by a dexamethasone (DEX) intravitreal implant. Materials and Methods. We performed a retrospective study of patients who underwent an SLT procedure for ocular hypertension induced by injection of a DEX intravitreal implant. Patients had, at least, one injection of the DEX-implant for symptomatic macular edema. SLT was delivered to 360°of the trabecular meshwork in two sessions. e primary outcome was a decrease in IOP, evaluated at one, three, and six months after the SLT procedure. Results. Twenty-six eyes of 22 patients were included. e mean intraocular pressure (IOP) measured after DEX-implant injection was 25.4 ± 5.4 mmHg, and the mean increase in IOP was 35.8 ± 14.6%. e mean follow-up after SLT was 18.3 ± 7.7 months. After SLT, the mean IOP dropped by 30.9% at one month (16.9 ± 4.5 mmHg, p � 0.01), 33.6% at three months (16.0 ± 2.7 mmHg, p 20%. No glaucoma surgery was required during the follow-up. e mean number of medications (1.65 ± 1.36) was significantly reduced at one (1.19 ± 1.20, p � 0.04), three (0.96 ± 1.03, p < 0.01), and six months (0.77 ± 0.95, p < 0.01) after SLT. Conclusion. SLT is an effective and safe procedure to control OHT following DEX-implant intravitreal injection

    Cataract and glaucoma combined surgery: XEN® gel stent versus nonpenetrating deep sclerectomy, a pilot study.

    No full text
    International audienceBackground: To compare the efficacy of phacoemulsification (PKE) combined with nonpenetrating deep sclerectomy (NPDS) with mitomycin C (MMC) versus XEN® gel stent with MMC.Methods: In this nonrandomized, retrospective, comparative, single-center pilot study, 105 consecutive eyes of 75 patients with uncontrolled primary open-angle glaucoma (POAG) and cataract who underwent PKE combined with either XEN implantation (n = 47) or NPDS (n = 58) between May 2013 and November 2018 were included. The primary outcome was complete success at 9 months, which was defined as intraocular pressure (IOP) ≤18, 15 or 12 mmHg without treatment; qualified success was IOP ≤18, 15 or 12 mmHg with antiglaucoma medications. Secondary outcome measures included the number of antiglaucoma medications, visual acuity (VA), and postoperative adverse events.Results: Using the 18 mmHg threshold, complete or qualified success was achieved in 69.6 and 89.1% in the PKE + XEN group, and 63.8 and 89.7% in the PKE + NPDS group (p = .54 and p = .93), respectively, at 9 months. The mean IOP decreased from 20.8 ± 6.8 mmHg to 16.2 ± 2.8 mmHg in the PKE + XEN group (p < .001, 18.9% mean drop), and from 21.5 ± 8.9 mmHg to 14.9 ± 3.9 mmHg in the PKE + NPDS group (p < .001, 25.6% mean drop). Best-corrected VA significantly improved (p < .001) in both groups. The mean number of antiglaucoma medications was significantly reduced from 2.66 ± 1.1 to 0.49 ± 1.0 in the PKE + XEN group (p < .001) and from 2.93 ± 0.9 to 0.69 ± 1.2 in the PKE + NPDS group (p < .001).Conclusions: The XEN stent combined with PKE seemed to be as effective and safe as PKE + NPDS at 9 months in this pilot study
    corecore