898 research outputs found

    Structure of 55Sc and development of the N=34 subshell closure

    Get PDF
    The low-lying structure of 55^{55}Sc has been investigated using in-beam Îł\gamma-ray spectroscopy with the 9^{9}Be(56^{56}Ti,55^{55}Sc+Îł\gamma)XX one-proton removal and 9^{9}Be(55^{55}Sc,55^{55}Sc+Îł\gamma)XX inelastic-scattering reactions at the RIKEN Radioactive Isotope Beam Factory. Transitions with energies of 572(4), 695(5), 1539(10), 1730(20), 1854(27), 2091(19), 2452(26), and 3241(39) keV are reported, and a level scheme has been constructed using γγ\gamma\gamma coincidence relationships and Îł\gamma-ray relative intensities. The results are compared to large-scale shell-model calculations in the sdsd-pfpf model space, which account for positive-parity states from proton-hole cross-shell excitations, and to it ab initio shell-model calculations from the in-medium similarity renormalization group that includes three-nucleon forces explicitly. The results of proton-removal reaction theory with the eikonal model approach were adopted to aid identification of positive-parity states in the level scheme; experimental counterparts of theoretical 1/21+1/2^{+}_{1} and 3/21+3/2^{+}_{1} states are suggested from measured decay patterns. The energy of the first 3/2−3/2^{-} state, which is sensitive to the neutron shell gap at the Fermi surface, was determined. The result indicates a rapid weakening of the N=34N=34 subshell closure in pfpf-shell nuclei at Z>20Z>20, even when only a single proton occupies the πf7/2\pi f_{7/2} orbital

    Gamma-Ray spectroscopy in the vicinity of Zr-108

    Get PDF
    F. Browne et al.; 4 págs.; 2 figs.; Presented at the Zakopane Conference on Nuclear Physics “Extremes of the Nuclear Landscape”, Zakopane, Poland, August 31–September 7, 2014; PACS numbers: 21.10.Re, 21.10.Tg, 23.20.Js, 27.60.+jThe half-lives of 2+121+ states were measured for 102,104102,104Zr and 106,108106,108Mo to test a new implementation of a LaBr33(Ce) array at the RIBF, RIKEN, Japan. The nuclei of interest were produced through the fission of a 345~MeV/nucleon 238238U beam and selected by the BigRIPS separator. Fission fragments were implanted into the WAS3ABi active stopper, surrounding which, 18 LaBr33(Ce) detectors provided fast γγ-ray detection. Timing between the LaBr33(Ce) array and plastic scintillators allowed for the measurement of half-lives of low-lying states. The preliminary results, which agree with literature values, are presented along with experimental details.This work was supported in part by the UK STFC, the UK NMO and D.O.E. grant No. DE-FG02-91ER-40609Peer Reviewe

    Shape evolution in 116,118 Ru: Triaxiality and transition between the O(6) and U(5) dynamical symmetries

    Get PDF
    116Ru and 118Ru have been studied via ÎČ-delayed Îł-ray spectroscopy of nuclei produced in fragmentation reactions at the Radioactive Ion-Beam Factory (RIBF) facility. Level schemes with positive-parity states up to spin J=6 have been constructed. The re

    Violent Recidivism: A Long-Time Follow-Up Study of Mentally Disordered Offenders

    Get PDF
    Background: In this prospective study, mentally disordered perpetrators of severe violent and/or sexual crimes were followed through official registers for 59 (range 8 to 73) months. The relapse rate in criminality was assessed, compared between offenders sentenced to prison versus forensic psychiatric care, and the predictive ability of various risk factors (criminological, clinical, and of structured assessment instruments) was investigated. Method: One hundred perpetrators were consecutively assessed between 1998 and 2001 by a clinical battery of established instruments covering DSM-IV diagnoses, psychosocial background factors, and structured assessment instruments (HCR-20, PCL-R, and life-time aggression (LHA)). Follow-up data was collected from official registers for: (i) recidivistic crimes, (ii) crimes during ongoing sanction. Results: Twenty subjects relapsed in violent criminality during ongoing sanctions (n = 6) or after discharge/parole (n = 14). Individuals in forensic psychiatric care spent significantly more time at liberty after discharge compared to those in prison, but showed significantly fewer relapses. Criminological (age at first conviction), and clinical (conduct disorder and substance abuse/dependence) risk factors, as well as scores on structured assessment instruments, were moderately associated with violent recidivism. Logistic regression analyses showed that the predictive ability of criminological risk factors versus clinical risk factors combined with scores from assessment instruments was comparable, with each set of variables managing to correctly classify about 80% of all individuals, but the only predictors that remained significant in multiple models were criminological (age at first conviction, and a history of substance abuse among primary relatives). Conclusions: Only one in five relapsed into serious criminality, with significantly more relapses among subjects sentenced to prison as compared to forensic psychiatric care. Criminological risk factors tended to be the best predictors of violent relapses, while few synergies were seen when the risk factors were combined. Overall, the predictive validity of common risk factors for violent criminality was rather weak

    A primary care, multi-disciplinary disease management program for opioid-treated patients with chronic non-cancer pain and a high burden of psychiatric comorbidity

    Get PDF
    BACKGROUND: Chronic non-cancer pain is a common problem that is often accompanied by psychiatric comorbidity and disability. The effectiveness of a multi-disciplinary pain management program was tested in a 3 month before and after trial. METHODS: Providers in an academic general medicine clinic referred patients with chronic non-cancer pain for participation in a program that combined the skills of internists, clinical pharmacists, and a psychiatrist. Patients were either receiving opioids or being considered for opioid therapy. The intervention consisted of structured clinical assessments, monthly follow-up, pain contracts, medication titration, and psychiatric consultation. Pain, mood, and function were assessed at baseline and 3 months using the Brief Pain Inventory (BPI), the Center for Epidemiological Studies-Depression Scale scale (CESD) and the Pain Disability Index (PDI). Patients were monitored for substance misuse. RESULTS: Eighty-five patients were enrolled. Mean age was 51 years, 60% were male, 78% were Caucasian, and 93% were receiving opioids. Baseline average pain was 6.5 on an 11 point scale. The average CESD score was 24.0, and the mean PDI score was 47.0. Sixty-three patients (73%) completed 3 month follow-up. Fifteen withdrew from the program after identification of substance misuse. Among those completing 3 month follow-up, the average pain score improved to 5.5 (p = 0.003). The mean PDI score improved to 39.3 (p < 0.001). Mean CESD score was reduced to 18.0 (p < 0.001), and the proportion of depressed patients fell from 79% to 54% (p = 0.003). Substance misuse was identified in 27 patients (32%). CONCLUSIONS: A primary care disease management program improved pain, depression, and disability scores over three months in a cohort of opioid-treated patients with chronic non-cancer pain. Substance misuse and depression were common, and many patients who had substance misuse identified left the program when they were no longer prescribed opioids. Effective care of patients with chronic pain should include rigorous assessment and treatment of these comorbid disorders and intensive efforts to insure follow up

    Search for Heavy Neutral and Charged Leptons in e+ e- Annihilation at LEP

    Get PDF
    A search for exotic unstable neutral and charged heavy leptons as well as for stable charged heavy leptons is performed with the L3 detector at LEP. Sequential, vector and mirror natures of heavy leptons are considered. No evidence for their existence is found and lower limits on their masses are set

    Research and developments in thin film silicon photovoltaics

    Get PDF
    The increasing demand for photovoltaic devices and the associated crystalline silicon feedstock demand scenario have led in the past years to the fast growth of the thin film silicon industry. The high potential for cost reduction and the suitability for building integration have initiated both industrial and research laboratories dynamisms for amorphous silicon and micro-crystalline silicon based photovoltaic technologies. The recent progress towards higher efficiencies thin film silicon solar cells obtained at the IMT-EPFL in Neuchatel in small-area laboratory and semi-large-area industrial Plasma Enhanced Chemical Vapor Deposition (PE-CVD) systems are reviewed. Advanced light trapping schemes are fundamental to reach high conversion efficiency and the potential of advanced Transparent Conductive Oxides (TCO) is presented, together with issues associated to the impact of the substrate morphology onto the growth of the silicon films. The recent improvements realized in amorphous-microcrystalline tandem solar cells on glass substrate are then presented, and the latest results on 1 cm2 cells are reported with up to 13.3 % initial efficiency for small-area reactors and up to 12.3 % initial for large-area industrial reactors. Finally, the different strategies to reach an improved light confinement in a thin film solar cell deposited on a flexible substrate are discussed, with the incorporation of asymmetric intermediate reflectors. Results of micromorph solar cells in the n-i-p configuration with up to 9.8 % stabilized efficiency are reported
    • 

    corecore