576 research outputs found

    Antenna Impedance in a Warm Plasma

    Get PDF
    Impedance of biconical and cylindrical dipoles in warm isotropic plasm

    Characterization of MMIC devices for active array antennas

    Get PDF
    Certain aspects of monolithic microwave integrated circuit (MMIC) interconnectivity were investigated. Considerations that lead to preserving the inherently reproducible characteristics of the MMIC are proposed. It is shown that at radio frequencies (RF) greater than 20 GHz, the transition from the MMIC device to other transmission media must be an accurate RF match. It is proposed that the RF match is sufficiently critical to include the transition as part of the delivered MMIC package. The model to analyze several transitions is presented. This model consists of a succession of abrupt discontinuities in printed circuit transmission lines. The analysis of these discontinuities is achieved by the Spectral Galerkin technique, to establish the modes and mode matching, to generate the generalized S parameters of the individual discontinuities. Preliminary results achieved with this method are presented. It is concluded that special effects should be coordinated by the active array antenna industry toward standardization of MMIC packaging and characterization

    A matrix equation solution by an optimization technique

    Get PDF
    The computer solution of matrix equations is often difficult to accomplish due to an ill-conditioned matrix or high noise levels. Two methods of solution are compared for matrices of various degrees of ill-conditioning and for various noise levels in the right hand side vector. One method employs the usual Gaussian elimination. The other solves the equation by an optimization technique and employs a function minimization subroutine

    Electromagnetic Scattering by Conducting Bodies of Revolution -- Solution Using Sub-Domain and Entire-Domain Basis Functions

    Get PDF
    Coordinated Science Laboratory was formerly known as Control Systems LaboratoryJoint Services Electronics Program / N00014-84-C-014

    Brightness of a phase-conjugating mirror behind a random medium

    Get PDF
    A random-matrix theory is presented for the reflection of light by a disordered medium backed by a phase-conjugating mirror. Two regimes are distinguished, depending on the relative magnitude of the inverse dwell time of a photon in the disordered medium and the frequency shift acquired at the mirror. The qualitatively different dependence of the reflectance on the degree of disorder in the two regimes suggests a distinctive experimental test for cancellation of phase shifts in a random medium.Comment: 4 pages LaTeX. 2 Postscript figures include

    Multicentricity of breast cancer: whole-organ analysis and clinical implications

    Get PDF
    We studied the spatial relationship within the breast between multicentric foci (MCF) and the primary tumour in 30 modified radical mastectomy specimens using Egan's correlated pathological-radiological method using 5 mm slices of the whole breast. The relative positions within the breast of the primary tumour and MCF were used to calculate the relative distribution of primary tumour and MCF in the four quadrants of the breast and the per cent breast volume that would be required to be excised to include all MCF. Nineteen (63%) breast harboured MCF. The relative distribution of primary tumour and MCF in the four breast quadrants was significantly different (P = 0.034). MCF were present beyond the index quadrant (25% of breast volume including the tumour) in as many as 79% (15/19) of breasts that harboured MCF; and in half the cases (15/30) when all breast were considered. This is in variance with the suggestion put forward previously that MCF are contained within the index quadrant in 90% of cases. Although the number of patients in the present series is small, the probability of our finding being due to play of chance is 1 in 1500. In a large series of breast conservation studies > 90% of early breast recurrences have been found to occur in the index quadrant. Our finding, that in half the patients (15/30) MCF are present in quadrants other than the index quadrant, suggests that MCF do not give rise to early breast recurrence

    3D-printed flat lens for microwave applications

    Get PDF
    This paper presents the design of a 3D-printed flat graded-index lens based on ray optics. The lens is comprised of several concentric dielectric rings with bespoke relative permittivities for transforming spherical waves into plane waves. 3D-printing was used to fabricate this lens with graded and tailored dielectric properties in a single process. The 3D-printed flat lens is low-cost and light-weight, but provides broadband and high gain performance. Measurement results show that the realised gain of the lens is 8 to 10 dB over the frequency band ranging from 12 to 18 GHz

    Pediatric integrative medicine: pediatrics\u27 newest subspecialty

    Get PDF
    BACKGROUND: Integrative medicine is defined as relationship-centered care that focuses on the whole person, is informed by evidence, and makes use of all appropriate therapeutic approaches, healthcare professionals and disciplines to achieve optimal health and healing, including evidence-based complementary and alternative medicine. Pediatric integrative medicine (PIM) develops and promotes this approach within the field of pediatrics. We conducted a survey to identify and describe PIM programs within academic children\u27s hospitals across North America. Key barriers and opportunities were identified for the growth and development of academic PIM initiatives in the US and Canada. METHODS: Academic PIM programs were identified by email and eligible for inclusion if they had each of educational, clinical, and research activities. Program directors were interviewed by telephone regarding their clinical, research, educational, and operational aspects. RESULTS: Sixteen programs were included. Most (75%) programs provided both inpatient and outpatient services. Seven programs operated with less than 1 FTE clinical personnel. Credentialing of complementary and alternative medicine (CAM) providers varied substantially across the programs and between inpatient and outpatient services. Almost all (94%) programs offered educational opportunities for residents in pediatrics and/or family medicine. One fifth (20%) of the educational programs were mandatory for medical students. Research was conducted in a range of topics, but half of the programs reported lack of research funding and/or time. Thirty-one percent of the programs relied on fee-for-service income. CONCLUSIONS: Pediatric integrative medicine is emerging as a new subspecialty to better help address 21st century patient concerns

    Carbide precipitates in solution-quenched PH13-8 Mo stainless steel: a small-angle neutron scattering investigation

    Get PDF
    This paper deals with the small-angle neutron scattering (SANS) investigation on solution-quenched PH13-8 Mo stainless steel. From the nature of the variation of the functionality of the profiles for varying specimen thickness and also from the transmission electron microscopy (TEM), it has been established that the small-angle scattering signal predominantly originates from the block-like metallic carbide precipitates in the specimen. The contribution due to double Bragg reflection is not significant in the present case. The single scattering profile has been extracted from the experimental profiles corresponding to different values of specimen thickness. In order to avoid complexity and non-uniqueness of the multi-parameter minimization for randomly oriented polydisperse block-like precipitate model, the data have been analyzed assuming randomly oriented polydisperse cylindrical particle model with a locked aspect ratio

    3D-printed millimeter wave lens antenna

    Get PDF
    © 2017 IEEE. In this work, we present a flat lens design using the Dial-a-Dielectric (DaD) and 3D-printing technique to realize the materials that are not available off-the-shelf. We design the proposed flat lens and compare its performance with that of the ray-optics (RO)-based lens. We find from the results that both designs show comparable performance
    • …
    corecore