101 research outputs found
Mapping The In-Plane Electric Field Inside Irradiated Diodes
A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of the Large Hadron Collider at CERN, which will significantly increase the rate of particle collisions and resulting particle tracks. During their operation in the ATLAS detector, sensors for the ITk strip tracker are expected to accumulate fluences up to 1.61015neq/cm2 (including a safety factor of 1.5), which will significantly affect their performance. One characteristic of interest for highly irradiated sensors is the shape and homogeneity of the electric field inside its active area. For the results presented here, diodes with edge structures similar to full size ATLAS sensors were irradiated up to fluences comparable to those in the ATLAS ITk strip tracker and their electric fields mapped using a micro-focused X-ray beam (beam diameter 23m2). This study shows the extension and shape of the electric field inside highly irradiated diodes over a range of applied bias voltages. Additionally, measurements of the outline of the depleted sensor areas allow a comparison of the measured leakage current for different fluences with expectations for the corresponding active areas
Mapping the depleted area of silicon diodes using a micro-focused X-ray beam
For the Phase-II Upgrade of the ATLAS detector at CERN, the current ATLAS Inner Detector will be replaced with the ATLAS Inner Tracker (ITk). The ITk will be an all-silicon detector, consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker are required to have a low leakage current up to bias voltages of -500 V to maintain a low noise and power dissipation. In order to minimise sensor leakage currents, particularly in the high-radiation environment inside the ATLAS detector, sensors are foreseen to be operated at low temperatures and to be manufactured from wafers with a high bulk resistivity of several kΩ·cm. Simulations showed the electric field inside sensors with high bulk resistivity to extend towards the sensor edge, which could lead to increased surface currents for narrow dicing edges. In order to map the electric field inside biased silicon sensors with high bulk resistivity, three diodes from ATLAS silicon strip sensor prototype wafers were studied with a monochromatic, micro-focused X-ray beam at the Diamond Light Source (Didcot, U.K.). For all devices under investigation, the electric field inside the diode was mapped and its dependence on the applied bias voltage was studied.Individual authors1 were supported in part by the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. The work at SCIPP4 was
supported by the Department of Energy, grant DE-SC0010107. This work5 issupported and financed in part by the Spanish Ministry of Science, Innovation
and Universities through the Particle Physics National Program, ref. FPA2015-65652-C4-4-R (MICINN/FEDER, UE), and co-financed with FEDER funds
Fatty acids homeostasis during fasting predicts protection from chemotherapy toxicity.
Fasting exerts beneficial effects in mice and humans, including protection from chemotherapy toxicity. To explore the involved mechanisms, we collect blood from humans and mice before and after 36 or 24 hours of fasting, respectively, and measure lipid composition of erythrocyte membranes, circulating micro RNAs (miRNAs), and RNA expression at peripheral blood mononuclear cells (PBMCs). Fasting coordinately affects the proportion of polyunsaturated versus saturated and monounsaturated fatty acids at the erythrocyte membrane; and reduces the expression of insulin signaling-related genes in PBMCs. When fasted for 24 hours before and 24 hours after administration of oxaliplatin or doxorubicin, mice show a strong protection from toxicity in several tissues. Erythrocyte membrane lipids and PBMC gene expression define two separate groups of individuals that accurately predict a differential protection from chemotherapy toxicity, with important clinical implications. Our results reveal a mechanism of fasting associated with lipid homeostasis, and provide biomarkers of fasting to predict fasting-mediated protection from chemotherapy toxicity.General: We thank Prof. Jose Maria. Ordovas for his kind suggestions; nutritionists Helena Marcos-Pasero, Elena Aguilar-Aguilar and Isabel Espinosa-Salinas for their help with volunteers management; Rosa Serrano for her help with animal experiments; Susana Molina for her advice with PBMC isolation; Luisa Mariscal, Domingo Fernandez, Lola Martinez, Diego Megias, Patricia Gonzalez, Fernando Pelaez, Anabel Sanz, Carolina Pola, Celia de la Calle, Ana Ortega, Ana Sagrera, Jose Miguel Frade, Elena Lopez-Guadamillas, Maribel Munoz, Susana Llanos, Andres Fernandez, Aranzazu Sierra, Andres Lopez, Noemi Haro and Ildefonso Rodriguez for their excellent technical and scientific support. Work at the laboratory of P.J.F.M. is funded by the Ramon Areces Foundation, (CIVP18A3891), Asociacion Espanola contra el Cancer-AECC (SIRTBIO-LABAE18008FERN), a Ramon y Cajal Award from the Spanish Ministry of Science, Innovation and Universities (MICINN) (RYC-2017-22335), RETOS projects Program of MICINN (SAF2017-85766-R) and the Portuguese Foundation for Science and Technology (FCT-MCTES, SFRH/BD/124022/2016). Work at the laboratory of ARM was funded by the MICINN (PID2019-110183RB-C21), Regional Government of Community of Madrid (P2018/BAA-4343-ALIBIRD2020-CM) and the Ramon Areces Foundation. Work at the laboratory of A.D.R. Funded by the Comunidad de Madrid-Talento Grant 2018-T1/BMD-11966 and the MICINN PID-2019-106893RA-100. Work at the laboratory of L.D. is funded by projects from the Health Research Fund (ISCIII FIS PI14/01374 and FISPI17/00508) and from a Manuel de Oya research fellowship from the Beer and Health Foundation. Work at the laboratory of A.E. is funded by a Ramon y Cajal Award from MICINN (RYC-2013-13546) and RETOS projects Program of the MICINN, co-funded by the European Regional Development Fund (ERDF) (SAF2015-67538-R). Work in the laboratory of M.S. was funded by the IRB and by grants from the Spanish Ministry of Economy co-funded by the European Regional Development Fund (ERDF) (SAF2013-48256-R), the European Research Council (ERC-2014-AdG/669622), and the "laCaixa" Foundation.S
Setups for eliminating static charge of the ATLAS18 strip sensors
Construction of the new all-silicon Inner Tracker (ITk), developed by the
ATLAS collaboration for the High Luminosity LHC, started in 2020 and is
expected to continue till 2028. The ITk detector will include 18,000 highly
segmented and radiation hard n+-in-p silicon strip sensors (ATLAS18), which are
being manufactured by Hamamatsu Photonics. Mechanical and electrical
characteristics of produced sensors are measured upon their delivery at several
institutes participating in a complex Quality Control (QC) program. The QC
tests performed on each individual sensor check the overall integrity and
quality of the sensor. During the QC testing of production ATLAS18 strip
sensors, an increased number of sensors that failed the electrical tests was
observed. In particular, IV measurements indicated an early breakdown, while
large areas containing several tens or hundreds of neighbouring strips with low
interstrip isolation were identified by the Full strip tests, and leakage
current instabilities were measured in a long-term leakage current stability
setup. Moreover, a high surface electrostatic charge reaching a level of
several hundreds of volts per inch was measured on a large number of sensors
and on the plastic sheets, which mechanically protect these sensors in their
paper envelopes. Accumulated data indicates a clear correlation between
observed electrical failures and the sensor charge-up. To mitigate the
above-described issues, the QC testing sites significantly modified the sensor
handling procedures and introduced sensor recovery techniques based on
irradiation of the sensor surface with UV light or application of intensive
flows of ionized gas. In this presentation, we will describe the setups
implemented by the QC testing sites to treat silicon strip sensors affected by
static charge and evaluate the effectiveness of these setups in terms of
improvement of the sensor performance
Identification and recovery of ATLAS18 strip sensors with high surface static charge
The new all-silicon Inner Tracker (ITk) is being constructed by the ATLAS collaboration to track charged particles produced at the High-Luminosity LHC. The outer portion of the ITk detector will include nearly 18,000 highly segmented and radiation hard silicon strip sensors (ATLAS18 design). Throughout the production of 22,000 sensors, the strip sensors are subjected to a comprehensive suite of mechanical and electrical tests as part of the Quality Control (QC) program. In a large fraction of the batches delivered to date, high surface electrostatic charge has been measured on both the sensors and the plastic sheets between which the sensors are packaged for shipping and handling rigidity. Aggregate data from across QC sites indicate a correlation between observed electrical failures and the sensor/plastic sheet charge build up. To mitigate these issues, the QC testing sites introduced recovery techniques involving UV light or flows of ionizing gas. Significant modifications to sensor handling procedures were made to prevent subsequent build up of static charge. This publication details a precise description of the issue, a variety of sensor recovery techniques, and trend analyses of sensors initially failing electrical tests (IV, strip scan, etc.)
Characterisation of strip silicon detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam
The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise
the physics potential through a sizable increase in the luminosity up to 6 · 1034 cm−2
s
−1
. A
consequence of this increased luminosity is the expected radiation damage at 3000 fb−1
after ten
years of operation, requiring the tracking detectors to withstand fluences to over 1 · 1016 1 MeV
neq/cm2
. In order to cope with the consequent increased readout rates, a complete re-design of the
current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at
the Diamond Light Source with a 3 µm FWHM 15 keV micro focused X-ray beam. The devices
under test were a 320 µm thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded
to a 130 nm CMOS binary readout chip (ABC130) and a 320 µm thick full size radial (end-cap)
strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout chips
(ABCN-25).
A resolution better than the inter strip pitch of the 74.5 µm strips was achieved for both detectors.
The effect of the p-stop diffusion layers between strips was investigated in detail for the wire bond
pad regions.
Inter strip charge collection measurements indicate that the effective width of the strip on the
silicon sensors is determined by p-stop regions between the strips rather than the strip pitch
Caspase-2 Mediated Apoptotic and Necrotic Murine Macrophage Cell Death Induced by Rough Brucella abortus
Brucella species are Gram-negative, facultative intracellular bacteria that cause zoonotic brucellosis. Survival and replication inside macrophages is critical for establishment of chronic Brucella infection. Virulent smooth B. abortus strain 2308 inhibits programmed macrophage cell death and replicates inside macrophages. Cattle B. abortus vaccine strain RB51 is an attenuated rough, lipopolysaccharide O antigen-deficient mutant derived from smooth strain 2308. B. abortus rough mutant RA1 contains a single wboA gene mutation in strain 2308. Our studies demonstrated that live RB51 and RA1, but not strain 2308 or heat-killed Brucella, induced both apoptotic and necrotic cell death in murine RAW264.7 macrophages and bone marrow derived macrophages. The same phenomenon was also observed in primary mouse peritoneal macrophages from mice immunized intraperitoneally with vaccine strain RB51 using the same dose as regularly performed in protection studies. Programmed macrophage cell death induced by RB51 and RA1 was inhibited by a caspase-2 inhibitor (Z-VDVAD-FMK). Caspase-2 enzyme activation and cleavage were observed at the early infection stage in macrophages infected with RB51 and RA1 but not strain 2308. The inhibition of macrophage cell death promoted the survival of rough Brucella cells inside macrophages. The critical role of caspase-2 in mediating rough B. abortus induced macrophage cell death was confirmed using caspase-2 specific shRNA. The mitochondrial apoptosis pathway was activated in macrophages infected with rough B. abortus as demonstrated by increase in mitochondrial membrane permeability and the release of cytochrome c to cytoplasm in macrophages infected with rough Brucella. These results demonstrate that rough B. abortus strains RB51 and RA1 induce apoptotic and necrotic murine macrophage cell death that is mediated by caspase-2. The biological relevance of Brucella O antigen and caspase-2-mediated macrophage cell death in Brucella pathogenesis and protective Brucella immunity is discussed
A precise measurement of the magnetic field in the corona of the black hole binary V404 Cygni
Observations of binary stars containing an accreting black hole or neutron star often show x-ray emission extending to high energies (>10 kilo–electron volts), which is ascribed to an accretion disk corona of energetic particles akin to those seen in the solar corona. Despite their ubiquity, the physical conditions in accretion disk coronae remain poorly constrained. Using simultaneous infrared, optical, x-ray, and radio observations of the Galactic black hole system V404 Cygni, showing a rapid synchrotron cooling event in its 2015 outburst, we present a precise 461 ± 12 gauss magnetic field measurement in the corona. This measurement is substantially lower than previous estimates for such systems, providing constraints on physical models of accretion physics in black hole and neutron star binary systems.
This article has a correction. Please see: http://science.sciencemag.org/content/360/6386/eaat927
Brain Changes in Long-Term Zen Meditators Using Proton Magnetic Resonance Spectroscopy and Diffusion Tensor Imaging: A Controlled Study
Introduction: This work aimed to determine whether 1H magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), diffusion-weighted imaging (DWI) and diffusion tensor imaging (DTI) are correlated with years of meditation and psychological variables in long-term Zen meditators compared to healthy non-meditator controls. Materials and Methods: Design. Controlled, cross-sectional study. Sample. Meditators were recruited from a Zen Buddhist monastery. The control group was recruited from hospital staff. Meditators were administered questionnaires on anxiety, depression, cognitive impairment and mindfulness. 1H-MRS (1.5 T) of the brain was carried out by exploring four areas: both thalami, both hippocampi, the posterior superior parietal lobule (PSPL) and posterior cingulate gyrus. Predefined areas of the brain were measured for diffusivity (ADC) and fractional anisotropy (FA) by MR-DTI. Results: Myo-inositol (mI) was increased in the posterior cingulate gyrus and Glutamate (Glu), N-acetyl-aspartate (NAA) and N-acetyl-aspartate/Creatine (NAA/Cr) was reduced in the left thalamus in meditators. We found a significant positive correlation between mI in the posterior cingulate and years of meditation (r = 0.518; p = .019). We also found significant negative correlations between Glu (r =20.452; p = .045), NAA (r =20.617; p = .003) and NAA/Cr (r =20.448; P = .047) in the left thalamus and years of meditation. Meditators showed a lower Apparent Diffusion Coefficient (ADC) in the left posterior parietal white matter than did controls, and the ADC was negatively correlated with years of meditation (r =20.4850, p = .0066). Conclusions: The results are consistent with the view that mI, Glu and NAA are the most important altered metabolites. This study provides evidence of subtle abnormalities in neuronal function in regions of the white matter in meditators
- …