5,893 research outputs found

    Modelling the control of bovine brucellosis in India.

    Get PDF
    Brucellosis imposes substantial impacts on livestock production and public health worldwide. A stochastic, age-structured model incorporating herd demographics was developed describing within- and between-herd transmission of Brucella abortus in dairy cattle herds. The model was fitted to data from a cross-sectional study conducted in Punjab State of India and used to evaluate the effectiveness of control strategies under consideration. Based on model results, stakeholder acceptance and constraints regarding vaccine supply, vaccination of replacement calves in large farms should be prioritized. Test and removal applied at early stages of the control programme where seroprevalence is high would not constitute an effective or acceptable use of resources because significant numbers of animals would be 'removed' (culled or not used for breeding) based on false positive results. To achieve sustained reductions in brucellosis, policymakers must commit to maintaining vaccination in the long term, which may eventually reduce frequency of infection in the livestock reservoir to a low enough level for elimination to be a realistic objective. This work provides key strategic insights into the control of brucellosis in India, which has the largest cattle population globally, and a general modelling framework for evaluating control strategies in endemic settings

    Molecular characterization of antibiotic-resistant Staphylococcus aureus from livestock (bovine and swine)

    Get PDF
    Aim: The aim of this study was to figure the prevalence, phenotypic and genotypic antibiotic resistance (AR) pattern of Staphylococcus aureus isolated from bovine and swine nares. Materials and Methods: Colonies with typical morphology on Baird-Parker agar supplemented with egg-yolk tellurite emulsion were selected and biochemically/genotypically identified as S. aureus. These strains were further subjected to epsilometer test for their sensitivity to various clinically important antibiotics and antibiotic susceptibility testing for amoxicillin/clavulanic acid, and double-disk diffusion testing was performed by the standard disc diffusion method following CLSI guidelines. S. aureus strains were also tested for the presence of AR genes, viz., blaZ, mecA, aacA-aphD, erm (ermA, ermB, ermC), tet (efflux genes tetK and tetL, tetM and tetO of the ribosomal protection family), and vanA. Results: The nasal cavities of 17 out of 47 randomly selected bovine and 20 out of 28 randomly selected swine were positive for S. aureus, representing the prevalence of 36.2% (95% confidence interval [CI]: 22.5-49.9) and 71.4% (95% CI: 54.7-88.1), respectively. Most of the S. aureus strains showed higher resistance to penicillin (94.6%, minimal inhibitory concentration [MIC] =1.5 Οg/ml) followed by ciprofloxacin (56.7%, MIC =32 Οg/ml) and tetracycline (18.9%, MIC =32 Οg/ml). About 10-15% of the strains were resistant to gentamicin (MIC 16 Οg/ml) and oxacillin (MIC 6-8 Οg/ml). None of the strains were resistant to vancomycin (MIC 0.25-1.5 Οg/ml). In this study, 32.4% strains were resistant to three or more than three antibiotics and prevalence of this multi-drug resistant S. aureus was 45% (95% CI: 26.6-63.4) and 17.6% (95% CI: 6.7- 28.5) in swine and bovine nasal samples, respectively. Four strains from pigs were borderline oxacillin-resistant S. aureus MIC 6-8 Οg/ml, but none were mecA positive. Two of these strains were β-lactamase hyperproducers. Among the resistance genes blaZ, tetK, tetL, tetM, ermB, and aacA-aphD were found. Conclusion: Our results demonstrated the absence of mecA and pvl gene, but the presence of multi-drug resistant S. aureus in the nares of healthy animals which has a potential to spread in a community

    Molecular characterization of Listeria monocytogenes in bovine milk and evaluating the sensitivity of PCR for direct detection in milk

    Get PDF
    Food-borne listeriosis, recognized as an emerging bacterial disease of humans and animals worldwide, is caused by L. monocytogenes with at least 95% of the strains isolated from foods and patients belonging to serovars 1/2a, 1/ 2b and 4b. Milk and dairy products were implicated as sources of listeriae in several widely publicized incidents, thus suggesting that the mammary glands of mastitic cattle may be an important reservoir of Listeria. In the present study, 350 bovine milk samples were collected for prevalence and molecular characterization studies of Listeria spp. The isolates were phenotypically and genotypically characterized by biochemical tests, haemolysis on sheep blood agar, CAMP test, PI-PLC assay and multiplex PCR targeting virulence cluster genes namely haemolysin (hlyA), PI-PLC (plcA), actin (actA), p60 (iap) and regulatory (prfA); along with multiplex PCR for typing major serovars targeting lmo0737, ORF2819, ORF2110 and prs genes. Four pathogenic L. monocytogenes were recovered indicating prevalence rate of 1.14% in milk while the overall prevalence rate of Listeria spp. was 1.42%. All the four pathogenic isolates were characterized as L. monocytogenes serotype 4b. Antibiogram of the pathogenic L. monocytogenes isolates revealed sensitivity for amikacin, gentamycin, norfloxacin and doxycyclin. Animal sera (169) screened by indirect ELISA for antibodies against listeriolysin O showed sero-positivity of 7.1%. Sensitivity of PCR for direct detection from milk was evaluated to be 8.8 × 105 L. monocytogenes cells/ml of milk. Thus, the presence of pathogenic strains of L. monocytogenes in raw milk appeared to be a cause for concern with profound public health implications

    Ethnicity and differences between clinic and ambulatory blood pressure measurements.

    Get PDF
    BACKGROUND: This study investigated the relationship of ethnicity to the differences between blood pressure (BP) measured in a clinic setting and by ambulatory blood pressure monitoring (ABPM) in individuals with a previous diagnosis of hypertension (HT) and without a previous diagnosis of hypertension (NHT). METHODS: A cross-sectional comparison of BP measurement was performed in 770 participants (white British (WB, 39%), South Asian (SA, 31%), and African Caribbean (AC, 30%)) in 28 primary care clinics in West Midlands, United Kingdom. Mean differences between daytime ABPM, standardized clinic (mean of 3 occasions), casual clinic (first reading on first occasion), and last routine BP taken at the general practitioner practice were compared in HT and NHT individuals. RESULTS: Daytime systolic and diastolic ABPM readings were similar to standardized clinic BP (systolic: 128 (SE 0.9) vs. 125 (SE 0.9) mm Hg (NHT) and 132 (SE 0.7) vs. 131 (SE 0.7) mm Hg (HT)) and were not associated with ethnicity to a clinically important extent. When BP was taken less carefully, differences emerged: casual clinic readings were higher than ABPM, particularly in the HT group where the systolic differences approached clinical relevance (131 (SE 1.2) vs. 129 (SE 1.0) mm Hg (NHT) and 139 (SE 0.9) vs. 133 (SE 0.7) mm Hg (HT)) and were larger in SA and AC hypertensive individuals (136 (SE 1.5) vs. 133 (SE 1.2) mm Hg (WB), 141 (SE 1.7) vs. 133 (SE 1.4) mm Hg (SA), and 142 (SE 1.6) vs. 134 (SE 1.3) mm Hg (AC); mean differences: 3 (0-7), P = 0.03 and 4 (1-7), P = 0.01, respectively). Differences were also observed for the last practice reading in SA and ACs. CONCLUSIONS: BP differences between ethnic groups where BP is carefully measured on multiple occasions are small and unlikely to alter clinical management. When BP is measured casually on a single occasion or in routine care, differences appear that could approach clinical relevance.This report presents independent research funded by the National Institute for Health Research (NIHR).The views expressed are those of the authors and not necessarily those of the NHS, the NIHR or the Department of HealthThis is a pre-copyedited, author-produced PDF of an article accepted for publication in American Journal of Hypertension following peer review. The version of record, Am J Hypertens (2014) doi: 10.1093/ajh/hpu211, is available online at: http://ajh.oxfordjournals.org/content/early/2014/11/18/ajh.hpu211.long

    Patient preferences for different methods of blood pressure measurement: is ethnicity relevant?

    Get PDF
    This is the author accepted manuscript. It is currently under an indefinite embargo pending publication by the Royal College of General Practitioners.Background:\textit{Background:} Ambulatory and/or home monitoring are recommended in the UK and North America for the diagnosis of hypertension but little is known about acceptability. Aim:\textit{Aim:} To determine the acceptability of different methods of measuring blood pressure to people from different ethnic minority groups. Design and setting:\textit{Design and setting:} Cross sectional study with focus groups in primary care. Methods:\textit{Methods:} People with and without hypertension of different ethnicities were assessed for acceptability of clinic, home and ambulatory blood pressure measurement using completion rate, questionnaire and focus groups. Results:\textit{Results:} 770 participants were included comprising white British (n=300), South Asian (n=241) and African Caribbean (n=229). White British participants had significantly higher successful completion rates across all monitoring modalities compared to the other ethnic groups, especially for ambulatory monitoring: white British (277 completed, 92%[89-95%]) vs South Asian (171, 71%[65-76%], p<0.001 and African Caribbean (188, 82%[77-87%], p<0.001) respectively. There were significantly lower acceptability scores for minority ethnic participants across all monitoring methods compared to white British. Focus group results highlighted self-monitoring as most acceptable and ambulatory monitoring least without consistent differences by ethnicity. Clinic monitoring was seen as inconvenient and anxiety provoking but with the advantage of immediate professional input. Conclusions:\textit{Conclusions:} Reduced acceptability and completion rates amongst minority ethnic groups raise important questions for the implementation and interpretation of blood pressure monitoring in general and ambulatory monitoring in particular. Selection of method for blood pressure monitoring should take into account clinical need and patient preference as well as consideration of potential cultural barriers to monitoring.National Institute for Health Research (Grant ID: PB-PG-1207-15042

    Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    Get PDF
    BACKGROUND: Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. METHODS: Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. RESULTS: A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). CONCLUSIONS: For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity of the former; higher specificity of the latter) were also not affected by ethnicity

    The prevalence and risk factors for human Brucella species infection in a cross-sectional survey of a rural population in Punjab, India

    Get PDF
    Brucellosis is an important neglected zoonosis. Effective cattle vaccines are available but are infrequently used in India, where rural households commonly own one or two cattle as sources of protein and income. We assessed the prevalence of infection and risk factors in humans

    Influence of ethnicity on acceptability of method of blood pressure monitoring: a cross-sectional study in primary care.

    Get PDF
    BACKGROUND: Ambulatory and/or home monitoring are recommended in the UK and the US for the diagnosis of hypertension but little is known about their acceptability. AIM: To determine the acceptability of different methods of measuring blood pressure to people from different minority ethnic groups. DESIGN AND SETTING: Cross-sectional study with focus groups in primary care in the West Midlands. METHOD: People of different ethnicities with and without hypertension were assessed for acceptability of clinic, home, and ambulatory blood pressure measurement using completion rate, questionnaire, and focus groups. RESULTS: A total of 770 participants were included, who were white British (n = 300), South Asian (n = 241), and African Caribbean (n = 229). White British participants had significantly higher successful completion rates across all monitoring modalities compared with the other ethnic groups, especially for ambulatory monitoring: white British (n = 277, 92% [95% confidence interval [CI] = 89% to 95%]) versus South Asian (n = 171, 71% [95% CI = 65% to 76%], P<0.001) and African Caribbean (n = 188, 82% [95% CI = 77% to 87%], P<0.001), respectively. There were significantly lower acceptability scores for minority ethnic participants across all monitoring methods compared with white British participants. Focus group results highlighted self-monitoring as most acceptable and ambulatory monitoring least acceptable without consistent differences by ethnicity. Clinic monitoring was seen as inconvenient and anxiety provoking but with the advantage of immediate professional input. CONCLUSION: Reduced acceptability and completion rates among minority ethnic groups raise important questions for the implementation and interpretation of blood pressure monitoring. Selection of method of blood pressure monitoring should take into account clinical need, patient preference, and potential cultural barriers to monitoring

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Full text link
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE
    • …
    corecore