257 research outputs found

    Foamed Nanocomposites for EMI Shielding Applications

    Get PDF
    INTRODUCTION : The addition of nanoparticles having specific properties inside a matrix with different properties creates a novel material that exhibits hybrid and even new properties. The nanocomposites presented in this paper combine the properties of foamed polymers (inexpensive, lightweight, easy to mould into any desired shape, etc.) with those of carbon nanotubes (CNTs). The addition of any conductive nanoparticles to an otherwise insulating matrix leads to a significant increase of the electrical conductivity. But CNTs have a very high aspect ratio; a much lower content of CNTs is therefore required to get the same conductivity increase as the one obtained with more compact nanoparticles. This is especially interesting for EMI shielding materials since, as will be explained in further details in this chapter, it is desirable for such materials to have a high conductivity but a low dielectric constant, in order to minimize the electromagnetic power outside the shield casing but also to minimize the power reflected back inside the casing, as is explained in section 2. In particular, two parameters of interest when comparing shielding materials are detailed and discussed. The polymer/CNTs nanocomposites were fabricated and characterized using a two-step diagnostic method. They were first characterized in their solid form, i.e. before the foaming process and the most interesting polymer matrices (with embedded CNTs) could be selected. This way, only the promising blends were foamed, therefore avoiding the unnecessary fabrication of a number of foams. These selected blends were foamed and then characterized. The samples, both solid and foamed, are described and their fabrication processes are briefly explained in section 3 while the characterization methods are shown in section 4. A simple electrical model is given and explained in section 5 and an optimized topology for the foams is also proposed in the second part of the same section. The measurement results for the solids and for the mono-layered and multi-layered foams are summarized and discussed in section 6. They are then compared to results obtained using the electrical model presented in the previous section and they are also correlated to rheological characterizations

    ESUR recommendations for MR imaging of the sonographically indeterminate adnexal mass: an update

    Get PDF
    An update of the 2010 published ESUR recommendations of MRI of the sonographically indeterminate adnexal mass integrating functional techniques is provided. An algorithmic approach using sagittal T2 and a set of transaxial T1 and T2WI allows categorization of adnexal masses in one of the following three types according to its predominant signal characteristics. T1 'bright' masses due to fat or blood content can be simply and effectively determined using a combination of T1W, T2W and FST1W imaging. When there is concern for a solid component within such a mass, it requires additional assessment as for a complex cystic or cystic-solid mass. For low T2 solid adnexal masses, DWI is now recommended. Such masses with low DWI signal on high b value image (e.g. > b 1000 s/mm2 ) can be regarded as benign. Any other solid adnexal mass, displaying intermediate or high DWI signal, requires further assessment by contrast-enhanced (CE)T1W imaging, ideally with DCE MR, where a type 3 curve is highly predictive of malignancy. For complex cystic or cystic-solid masses, both DWI and CET1W—preferably DCE MRI—is recommended. Characteristic enhancement curves of solid components can discriminate between lesions that are highly likely malignant and highly likely benign

    Impact of DWI and ADC values in ovarian-adnexal reporting and data system (O-RADS) MRI score

    Get PDF
    Purpose: Introduce DWI and quantitative ADC evaluation in O-RADS MRI system and observe how diagnostic performance changes. Assess its validity and reproducibility between readers with different experience in female pelvic imaging. Finally, evaluate any correlation between ADC value and histotype in malignant lesions. Materials and methods: In total, 173 patients with 213 indeterminate adnexal masses (AMs) on ultrasound were subjected to MRI examination, from which 140 patients with 172 AMs were included in the final analysis. Standardised MRI sequences were used, including DWI and DCE sequences. Two readers, blinded to histopathological data, retrospectively classified AMs according to the O-RADS MRI scoring system. A quantitative analysis method was applied by placing a ROI on the ADC maps obtained from single-exponential DWI sequences. AMs considered benign (O-RADS MRI score 2) were excluded from the ADC analysis. Results: Excellent inter-reader agreement was found in the classification of lesions according to the O-RADS MRI score (K = 0.936; 95% CI). Two ROC curves were created to determine the optimal cut-off value for the ADC variable between O-RADS MRI categories 3-4 and 4-5, respectively, 1.411 × 10-3 mm2/sec and 0.849 × 10-3 mm2/sec. Based on these ADC values, 3/45 and 22/62 AMs were upgraded, respectively, to score 4 and 5, while 4/62 AMs were downgraded to score 3. ADC values correlated significantly with the ovarian carcinoma histotype (p value < 0.001). Conclusion: Our study demonstrates the prognostic potential of DWI and ADC values in the O-RADS MRI classification for better radiological standardisation and characterisation of AMs

    Axillary lymphadenopathy at the time of COVID-19 vaccination: ten recommendations from the European Society of Breast Imaging (EUSOBI).

    Get PDF
    Unilateral axillary lymphadenopathy is a frequent mild side effect of COVID-19 vaccination. European Society of Breast Imaging (EUSOBI) proposes ten recommendations to standardise its management and reduce unnecessary additional imaging and invasive procedures: (1) in patients with previous history of breast cancer, vaccination should be performed in the contralateral arm or in the thigh; (2) collect vaccination data for all patients referred to breast imaging services, including patients undergoing breast cancer staging and follow-up imaging examinations; (3) perform breast imaging examinations preferentially before vaccination or at least 12 weeks after the last vaccine dose; (4) in patients with newly diagnosed breast cancer, apply standard imaging protocols regardless of vaccination status; (5) in any case of symptomatic or imaging-detected axillary lymphadenopathy before vaccination or at least 12 weeks after, examine with appropriate imaging the contralateral axilla and both breasts to exclude malignancy; (6) in case of axillary lymphadenopathy contralateral to the vaccination side, perform standard work-up; (7) in patients without breast cancer history and no suspicious breast imaging findings, lymphadenopathy only ipsilateral to the vaccination side within 12 weeks after vaccination can be considered benign or probably-benign, depending on clinical context; (8) in patients without breast cancer history, post-vaccination lymphadenopathy coupled with suspicious breast finding requires standard work-up, including biopsy when appropriate; (9) in patients with breast cancer history, interpret and manage post-vaccination lymphadenopathy considering the timeframe from vaccination and overall nodal metastatic risk; (10) complex or unclear cases should be managed by the multidisciplinary team

    Proteome-wide identification of poly(ADP-ribose) binding proteins and poly(ADP-ribose)-associated protein complexes

    Get PDF
    Poly(ADP-ribose) (pADPr) is a polymer assembled from the enzymatic polymerization of the ADP-ribosyl moiety of NAD by poly(ADP-ribose) polymerases (PARPs). The dynamic turnover of pADPr within the cell is essential for a number of cellular processes including progression through the cell cycle, DNA repair and the maintenance of genomic integrity, and apoptosis. In spite of the considerable advances in the knowledge of the physiological conditions modulated by poly(ADP-ribosyl)ation reactions, and notwithstanding the fact that pADPr can play a role of mediator in a wide spectrum of biological processes, few pADPr binding proteins have been identified so far. In this study, refined in silico prediction of pADPr binding proteins and large-scale mass spectrometry-based proteome analysis of pADPr binding proteins were used to establish a comprehensive repertoire of pADPr-associated proteins. Visualization and modeling of these pADPr-associated proteins in networks not only reflect the widespread involvement of poly(ADP-ribosyl)ation in several pathways but also identify protein targets that could shed new light on the regulatory functions of pADPr in normal physiological conditions as well as after exposure to genotoxic stimuli

    An International Consensus Statement

    Get PDF
    Publisher Copyright: © 2024 No AuthorThe International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) and International Deep Endometriosis Analysis (IDEA) group, the European Endometriosis League (EEL), the European Society for Gynaecological Endoscopy (ESGE), the European Society of Human Reproduction and Embryology (ESHRE), the International Society for Gynecologic Endoscopy (ISGE), the American Association of Gynecologic Laparoscopists (AAGL) and the European Society of Urogenital Radiology (ESUR) elected an international, multidisciplinary panel of gynecological surgeons, sonographers and radiologists, including a steering committee, which searched the literature for relevant articles in order to review the literature and provide evidence-based and clinically relevant statements on the use of imaging techniques for non-invasive diagnosis and classification of pelvic deep endometriosis. Preliminary statements were drafted based on review of the relevant literature. Following two rounds of revisions and voting orchestrated by chairs of the participating societies, consensus statements were finalized. A final version of the document was then resubmitted to the society chairs for approval. Twenty statements were drafted, of which 14 reached strong and three moderate agreement after the first voting round. The remaining three statements were discussed by all members of the steering committee and society chairs and rephrased, followed by an additional round of voting. At the conclusion of the process, 14 statements had strong and five statements moderate agreement, with one statement left in equipoise. This consensus work aims to guide clinicians involved in treating women with suspected endometriosis during patient assessment, counseling and planning of surgical treatment strategies.proofinpres

    European Society of Breast Imaging (EUSOBI) guidelines on the management of axillary lymphadenopathy after COVID-19 vaccination: 2023 revision

    Get PDF
    Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid

    Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging

    Get PDF
    Abstract: We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered

    Functionalized polypropylenes as efficient dispersing agents for carbon nanotubes in a polypropylene matrix; application to electromagnetic interference (EMI) absorber materials

    Full text link
    Carbon nanotubes (CNTs) have been dispersed within polypropylene with the purpose to prepare electromagnetic interference (EMI) absorbers. In order to limit the reflectivity of the electromagnetic waves at the interface of the materials while achieving good absorbing properties, the CNTs concentration must be kept low (<3 wt%) which means that a perfect dispersion must be ensured. Since CNTs do not disperse well within apolar polymer matrices such as polypropylene, two compatibilizers bearing aromatic moieties, i.e. pyrene and pyridine, able to develop π-π interactions with the CNTs have been synthesized starting from polypropylene grafted by maleic anhydride (PP-g-MA). A masterbatch is first prepared by dispersion of CNTs within the compatibilizers by melt-mixing and coprecipitation followed by further dispersion within the PP matrix. Rheological and electromagnetic characterizations of the nanocomposites have demonstrated the efficiency of these compatibilizers to promote the dispersion of CNTs in PP and the good EMI shielding effectiveness of the PP matrix at a low CNTs concentration (2 wt%)
    corecore