64 research outputs found

    Preparation and in vitro Characterization of Porous Carrier–Based Glipizide Floating Microspheres for Gastric Delivery

    Get PDF
    Floating microspheres have been utilized to obtain prolonged and uniform release of drug in the stomach for development of once-daily formulations. A controlled-release system designed to increase residence time in the stomach without contact with the mucosa was achieved through the preparation of floating microspheres by the emulsion solvent diffusion technique, using (i) calcium silicate (CS) as porous carrier; (ii) glipizide, an oral hypoglycemic agent; and (iii) Eudragit® S as polymer. The effects of various formulations and process variables on the internal and external particle morphology, micromeritic properties, in vitro floating behavior, drug loading, and in vitro drug release were studied. The microspheres were found to be regular in shape and highly porous. The prepared microspheres exhibited prolonged drug release (~8 h) and remained buoyant for >10 h. The mean particle size increased and the drug release rate decreased at higher polymer concentrations. No significant effect of the stirring rate during preparation on drug release was observed. In vitro studies demonstrated diffusion-controlled drug release from the microspheres. Microsphere formulation CS4, containing 200 mg calcium silicate, showed the best floating ability (88% buoyancy) in simulated gastric fluid. The release pattern of glipizide in simulated gastric fluid from all floating microspheres followed the Higuchi matrix model and the Peppas-Korsmeyer model

    The IMEx coronavirus interactome: an evolving map of Coronaviridae-host molecular interactions

    Get PDF
    The current coronavirus disease of 2019 (COVID-19) pandemic, caused by the severe acute respiratory syndrome coronavirus (SARS-CoV)-2, has spurred a wave of research of nearly unprecedented scale. Among the different strategies that are being used to understand the disease and develop effective treatments, the study of physical molecular interactions can provide fine-grained resolution of the mechanisms behind the virus biology and the human organism response. We present a curated dataset of physical molecular interactions focused on proteins from SARS-CoV-2, SARS-CoV-1 and other members of the Coronaviridae family that has been manually extracted by International Molecular Exchange (IMEx) Consortium curators. Currently, the dataset comprises over 4400 binarized interactions extracted from 151 publications. The dataset can be accessed in the standard formats recommended by the Proteomics Standards Initiative (HUPO-PSI) at the IntAct database website (https://www.ebi.ac.uk/intact) and will be continuously updated as research on COVID-19 progresses

    Systematic review with meta-analysis: cytokines in fibromyalgia syndrome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To perform a systematic review and meta-analysis on cytokine levels in patients with fibromyalgia syndrome (FMS).</p> <p>Methods</p> <p>Through December 2010 we systematically reviewed the databases PubMed, MEDLINE, and PsycINFO and screened the reference lists of 22 review articles for suitable original articles. Original articles investigating cytokines in patients with FMS were included. Data were extracted by two independent authors. Differences of the cytokine levels of FMS patients and controls were summarized by standardized mean differences (SMD) using a random effects model. Study quality was assessed applying methodological scores: modified Center of Evidence Based Medicine, Newcastle-Ottawa-Scale, and Würzburg Methodological Quality Score.</p> <p>Results</p> <p>Twenty-five articles were included investigating 1255 FMS patients and 800 healthy controls. Data of 13/25 studies entered meta-analysis. The overall methodological quality of studies was low. The results of the majority of studies were not comparable because methods, investigated material, and investigated target cytokines differed. Systematic review of the selected 25 articles revealed that FMS patients had higher serum levels of interleukin (IL)-1 receptor antagonist, IL-6, and IL-8, and higher plasma levels of IL-8. Meta-analysis of eligible studies showed that FMS patients had higher plasma IL-6 levels compared to controls (SMD = -0.34 [-0.64, -0.03] 95% CI; p = 0.03). The majority of investigated cytokines were not different between patients and controls.</p> <p>Conclusions</p> <p>The pathophysiological role of cytokines in FMS is still unclear. Studies of higher quality and with higher numbers of subjects are needed.</p

    Photostability of commercial sunscreens upon sun exposure and irradiation by ultraviolet lamps

    Get PDF
    BACKGROUND: Sunscreens are being widely used to reduce exposure to harmful ultraviolet (UV) radiation. The fact that some sunscreens are photounstable has been known for many years. Since the UV-absorbing ingredients of sunscreens may be photounstable, especially in the long wavelength region, it is of great interest to determine their degradation during exposure to UV radiation. Our aim was to investigate the photostability of seven commercial sunscreen products after natural UV exposure (UVnat) and artificial UV exposure (UVart). METHODS: Seven commercial sunscreens were studied with absorption spectroscopy. Sunscreen product, 0.5 mg/cm(2), was placed between plates of silica. The area under the curve (AUC) in the spectrum was calculated for UVA (320–400 nm), UVA1 (340–400 nm), UVA2 (320–340 nm) and UVB (290–320 nm) before (AUC(before)) and after (AUC(after)) UVart (980 kJ/m(2 )UVA and 12 kJ/m(2 )of UVB) and before and after UVnat. If theAUC Index (AUCI), defined as AUCI = AUC(after)/AUC(before), was > 0.80, the sunscreen was considered photostable. RESULTS: Three sunscreens were unstable after 90 min of UVnat; in the UVA range the AUCI was between 0.41 and 0.76. In the UVB range one of these sunscreens was unstable with an AUCI of 0.75 after 90 min. Three sunscreens were photostable after 120 min of UVnat; in the UVA range the AUCI was between 0.85 and 0.99 and in the UVB range between 0.92 and 1.0. One sunscreen showed in the UVA range an AUCI of 0.87 after UVnat but an AUCI of 0.72 after UVart. Five of the sunscreens were stable in the UVB region. CONCLUSION: The present study shows that several sunscreens are photounstable in the UVA range after UVnat and UVart. There is a need for a standardized method to measure photostability, and the photostability should be marked on the sunscreen product

    The MIntAct project—IntAct as a common curation platform for 11 molecular interaction databases

    Get PDF
    IntAct (freely available at http://www.ebi.ac.uk/intact) is an open-source, open data molecular interaction database populated by data either curated from the literature or from direct data depositions. IntAct has developed a sophisticated web-based curation tool, capable of supporting both IMEx- and MIMIx-level curation. This tool is now utilized by multiple additional curation teams, all of whom annotate data directly into the IntAct database. Members of the IntAct team supply appropriate levels of training, perform quality control on entries and take responsibility for long-term data maintenance. Recently, the MINT and IntAct databases decided to merge their separate efforts to make optimal use of limited developer resources and maximize the curation output. All data manually curated by the MINT curators have been moved into the IntAct database at EMBL-EBI and are merged with the existing IntAct dataset. Both IntAct and MINT are active contributors to the IMEx consortium (http://www.imexconsortium.org

    Capturing variation impact on molecular interactions in the IMEx Consortium mutations data set

    Get PDF
    The current wealth of genomic variation data identified at nucleotide level presents the challenge of understanding by which mechanisms amino acid variation affects cellular processes. These effects may manifest as distinct phenotypic differences between individuals or result in the development of disease. Physical interactions between molecules are the linking steps underlying most, if not all, cellular processes. Understanding the effects that sequence variation has on a molecule's interactions is a key step towards connecting mechanistic characterization of nonsynonymous variation to phenotype. We present an open access resource created over 14 years by IMEx database curators, featuring 28,000 annotations describing the effect of small sequence changes on physical protein interactions. We describe how this resource was built, the formats in which the data is provided and offer a descriptive analysis of the data set. The data set is publicly available through the IntAct website and is enhanced with every monthly release

    Effect of Cryogrinding on Chemical Stability of the Sparingly Water-Soluble Drug Furosemide

    Get PDF
    Purpose To investigate the effect of cryogrinding on chemical stability of the diuretic agent furosemide and its mixtures with selected excipients. Methods Furosemide was ground at liquid nitrogen temperature for 30, 60, 120 and 180 min. Mixtures of furosemide-PVP and furosemide-inulin (1:1) were milled under cryogenic conditions. Materials were analyzed by XRD, UPLC, MS and NMR. Results Upon increasing the milling time, a significant build-up of an unidentified impurity 1, probably the main degradation product, was noticed. Cogrinding of furosemide with PVP and inulin worsened chemical stabilization of the pharmaceutical. The main degradation product formed upon cryomilling was subsequently identified as 4-chloro-5-sulfamoylanthranilic acid (CSA). Based on some theoretical considerations involving specific milling conditions, the milling intensity and an expected specific milling dose have been calculated. Results indicate that cryogenic grinding is capable to initiate mechanically induced decomposition of furosemide.Conclusions Cryogenic grinding can activate and accelerate not only structural changes (solid state amorphization) but also chemical decomposition of pharmaceuticals. A cryogenic milling device should be considered as a chemical reactor, where under favourable conditions chemical reactions could be mechanically initiated

    Fluid challenges in intensive care: the FENICE study A global inception cohort study

    Get PDF
    Fluid challenges (FCs) are one of the most commonly used therapies in critically ill patients and represent the cornerstone of hemodynamic management in intensive care units. There are clear benefits and harms from fluid therapy. Limited data on the indication, type, amount and rate of an FC in critically ill patients exist in the literature. The primary aim was to evaluate how physicians conduct FCs in terms of type, volume, and rate of given fluid; the secondary aim was to evaluate variables used to trigger an FC and to compare the proportion of patients receiving further fluid administration based on the response to the FC.This was an observational study conducted in ICUs around the world. Each participating unit entered a maximum of 20 patients with one FC.2213 patients were enrolled and analyzed in the study. The median [interquartile range] amount of fluid given during an FC was 500 ml (500-1000). The median time was 24 min (40-60 min), and the median rate of FC was 1000 [500-1333] ml/h. The main indication for FC was hypotension in 1211 (59 %, CI 57-61 %). In 43 % (CI 41-45 %) of the cases no hemodynamic variable was used. Static markers of preload were used in 785 of 2213 cases (36 %, CI 34-37 %). Dynamic indices of preload responsiveness were used in 483 of 2213 cases (22 %, CI 20-24 %). No safety variable for the FC was used in 72 % (CI 70-74 %) of the cases. There was no statistically significant difference in the proportion of patients who received further fluids after the FC between those with a positive, with an uncertain or with a negatively judged response.The current practice and evaluation of FC in critically ill patients are highly variable. Prediction of fluid responsiveness is not used routinely, safety limits are rarely used, and information from previous failed FCs is not always taken into account
    corecore