7 research outputs found

    An overview of the utilisation of microalgae biomass derived from nutrient recycling of wet market wastewater and slaughterhouse wastewater

    Get PDF
    Microalgae have high nutritional values for aquatic organisms compared to fish meal, because microalgae cells are rich in proteins, lipids, and carbohydrates. However, the high cost for the commercial production of microalgae biomass using fresh water or artificial media limits its use as fish feed. Few studies have investigated the potential of wet market wastewater and slaughterhouse wastewater for the production of microalgae biomass. Hence, this study aims to highlight the potential of these types of wastewater as an alternative superior medium for microalgae biomass as they contain high levels of nutrients required for microalgae growth. This paper focuses on the benefits of microalgae biomass produced during the phycore-mediation of wet market wastewater and slaughterhouse wastewater as fish feed. The extraction techniques for lipids and proteins as well as the studies conducted on the use of microalgae biomass as fish feed were reviewed. The results showed that microalgae biomass can be used as fish feed due to feed utilisation efficiency, physiological activity, increased resistance for several diseases, improved stress response, and improved protein retention

    Strength Characteristics of Polyurethane (PU) With Modified Sand

    No full text
    Abstract. Soil stabilisation is defined as a technique to improve the engineering characteristics in order to improve the parameters such as shear strength, compressibility, density, hydraulic conductivity. There are many techniques that can be used for different purposes by enhancing some aspects of soil behaviour and improve the strength and properties of soil. One of the cheapest techniques is by using Polyurethane grout, which is workable for construction and enhances the performance of soil compressive strength. Polyurethane (PU) foam is non-toxic, having an indefinite life span and non-environment unfriendly. PU is a chemical substance that normally used in polymer industries for instance resilience foam seating, rigid foam insulation panels and microcellular foam seals. In this research, different percentages of PU content are mixed with sand to test the compressive strength of modified sand. The compressive strength of sand is determined by conducting the Unconfined Compression Test (UCT) with the mold samples of 50mm diameter and 100mm height. The test determines the compressive strength and generates the stress-strain relationship of the modified sand. It is shown that the compressive strength of modified sand will gradually increase with an increasing PU content percentage (varying from 10% (20 kPa) -95% (500 kPa). Conclusively, this research could be used as the benchmark of ground improvement technique

    A frequency-reconfigurable microstrip antenna with constant dipole-like radiation patterns using single bias, triple varactor tuning with reduced complexity

    No full text
    Abstract This work proposes a novel frequency-reconfigurable circular patch antenna incorporated with a rectangular slot and a narrow slot capable of producing constant dipole-like radiation patterns. The antenna compactness is achieved with the integration of the rectangular slot defected ground structure (DGS) on the ground. The proposed antenna is able to perform continuous frequency tuning between 1.91 and 2.77 GHz with a frequency ratio of 1.5:1, in addition to stable dipole-like radiation patterns. The resonant frequency of the antenna is controlled by tuning a simple DC biasing network that consists of three RF varactor diodes located on the narrow slot DGS. Implementing the DC biasing network at the narrow slot DGS while maintaining the large slot DGS helps the antenna miniaturization and maintains the constant dipole-like radiation pattern over all frequency tuning range. The results are validated via simulations and experimental validations in terms of reflection coefficients and the radiation patterns. Measurements indicated that an impedance bandwidth of 85 MHz is featured for each tuned frequency band, with dipole-like patterns and an average gain of 1.57 dBi

    ATLAS

    No full text
    % ATLAS \\ \\ ATLAS is a general-purpose experiment for recording proton-proton collisions at LHC. The ATLAS collaboration consists of 144 participating institutions (June 1998) with more than 1750~physicists and engineers (700 from non-Member States). The detector design has been optimized to cover the largest possible range of LHC physics: searches for Higgs bosons and alternative schemes for the spontaneous symmetry-breaking mechanism; searches for supersymmetric particles, new gauge bosons, leptoquarks, and quark and lepton compositeness indicating extensions to the Standard Model and new physics beyond it; studies of the origin of CP violation via high-precision measurements of CP-violating B-decays; high-precision measurements of the third quark family such as the top-quark mass and decay properties, rare decays of B-hadrons, spectroscopy of rare B-hadrons, and Bs0 B ^0 _{s} -mixing. \\ \\The ATLAS dectector, shown in the Figure includes an inner tracking detector inside a 2~T~solenoid providing an axial field, electromagnetic and hadronic calorimeters outside the solenoid and in the forward regions, and barrel and end-cap air-core-toroid muon spectrometers. The precision measurements for photons, electrons, muons and hadrons, and identification of photons, electrons, muons, τ\tau-leptons and b-quark jets are performed over η| \eta | < 2.5. The complete hadronic energy measurement extends over η| \eta | < 4.7. \\ \\The inner tracking detector consists of straw drift tubes interleaved with transition radiators for robust pattern recognition and electron identification, and several layers of semiconductor strip and pixel detectors providing high-precision space points. \\ \\The e.m. calorimeter is a lead-Liquid Argon sampling calorimeter with an integrated preshower detector and a presampler layer immediately behind the cryostat wall for energy recovery. The end-cap hadronic calorimeters also use Liquid Argon technology, with copper absorber plates. The end-cap cryostats house the e.m., hadronic and forward calorimeters (tungsten-Liquid Argon sampling). The barrel hadronic calorimeter is an iron-scintillating tile sampling calorimeter with longitudinal tile geometry. \\ \\Air-core toroids are used for the muon spectrometer. Eight superconducting coils with warm voussoirs are used in the barrel region complemented with superconducting end-cap toroids in the forward regions. The toroids will be instrumented with Monitored Drift Tubes (Cathode Strip Chambers at large rapidity where there are high radiation levels). The muon trigger and second coordinate measurement for muon tracks are provide

    Outcome after failure of allogeneic hematopoietic stem cell transplantation in children with acute leukemia: a study by the société Francophone de greffe de moelle et de thérapie cellulaire (SFGM-TC)

    No full text
    International audienc
    corecore