112 research outputs found

    Bond Strength Degradation for Prestressed Steel and Carbon FRP Bars in High-Performance Self-Consolidating Concrete at Elevated Temperatures and in Fire

    Get PDF
    Novel structures are emerging utilizing high performance, self-consolidating, fibre-reinforced concrete (HPSCC) reinforced with high-strength, lightweight, and non-corroding prestressed reinforcement. One example of this is a new type of precast carbon fibre reinforced polymer (CFRP) pretensioned HPSCC panel intended as load-bearing panels for building envelopes. As for all load-bearing structural members in building applications, the performance of these members in fire must be understood before they can be used with confidence. In particular, the bond performance of CFRP prestressing reinforcement at elevated temperatures is not well known. This paper examines the fire performance of these new types of structural elements, placing particular emphasis on the bond performance of CFRP and steel wire prestressing reinforcement at elevated temperatures. The results of large-scale fire tests and transient high temperature tensile and bond-pullout tests on CFRP and steel prestressing bars embedded in HPSCC cylinders are presented and discussed to shed light on the fire performance of these structural elements

    Reference instruments based on spectrometric measurement with Lucas Cells

    Get PDF
    The Bundesamt fĂŒr Strahlenschutz (Berlin, Germany) and the Paul Scherrer Institute (Villigen, Switzerland) both operate accredited calibration laboratories for radon gas activity concentration. Both the institutions use Lucas Cells as detector in their reference instrumentation due to the low dependence of this detector type on variations in environmental conditions. As a further measure to improve the quality of the reference activity concentration, a spectrometric method of data evaluation has been applied. The electric pulses from the photomultiplier tube coupled to the Lucas Cells are subjected to a pulse height analysis. The stored pulse height spectra are analysed retrospectively to compensate for fluctuations in the electric parameters of the instrumentation during a measurement. The reference instrumentation of both the laboratories is described with the respective spectrum evaluation procedures. The methods of obtaining traceability to the primary calibration laboratories of Germany and Switzerland and data of performance tests are presente

    USING GASEOUS EMISSIONS OF A PROTON ACCELERATOR FACILITY AS TRACER FOR SMALL-SCALE ATMOSPHERIC DISPERSION

    Get PDF
    The gaseous effluents of the proton accelerator facility located in the Western part of the Paul Scherrer Institute, Aargau, Switzerland, contain a mixture of positron emitters (50 % 15O, 20 % 13N and 30 % 11C). For the experimental verification of a future upgrade of the dispersion model in the complex topography of the Aare valley, a measuring campaign using three continuous gamma-spectrometric measuring stations was launched in 2011. The concept of a modified man-made-gross-count (MMGC) ratio yields a clear signal associated with the positron emitters while minimising the influence of radon progeny rain-out events. A dependence of the measured MMGC ratios on the emitted activity and wind direction could be demonstrated using frequency distributions of the modified MMGC ratio measured in 2012 and 2013. A significant fraction of high MMGC-ratio values was found associated with dispersion directions (based on measurements of the wind direction in 70 m above ground) not towards or even against the direction between stack and measuring statio

    New apparatus for DTA at 2000 bar: thermodynamic studies on Au, Ag, Al and HTSC oxides

    Full text link
    A new DTA (Differential Thermal Analysis) device was designed and installed in a Hot Isostatic Pressure (HIP) furnace in order to perform high-pressure thermodynamic investigations up to 2 kbar and 1200C. Thermal analysis can be carried out in inert or oxidising atmosphere up to p(O2) = 400 bar. The calibration of the DTA apparatus under pressure was successfully performed using the melting temperature (Tm) of pure metals (Au, Ag and Al) as standard calibration references. The thermal properties of these metals have been studied under pressure. The values of DV (volume variation between liquid and solid at Tm), ROsm (density of the solid at Tm) and ALPHAm (linear thermal expansion coefficient at Tm) have been extracted. A very good agreement was found with the existing literature and new data were added. This HP-DTA apparatus is very useful for studying the thermodynamics of those systems where one or more volatile elements are present, such as high TC superconducting oxides. DTA measurements have been performed on Bi,Pb(2223) tapes up to 2 kbar under reduced oxygen partial pressure (p(O2) = 0.07 bar). The reaction leading to the formation of the 2223 phase was found to occur at higher temperatures when applying pressure: the reaction DTA peak shifted by 49C at 2 kbar compared to the reaction at 1 bar. This temperature shift is due to the higher stability of the Pb-rich precursor phases under pressure, as the high isostatic pressure prevents Pb from evaporating.Comment: 6 figures, 3 tables, Thermodynamics, Thermal property, Bi-2223, fundamental valu

    Sub- and above barrier fusion of loosely bound 6^6Li with 28^{28}Si

    Full text link
    Fusion excitation functions are measured for the system 6^6Li+28^{28}Si using the characteristic Îł\gamma-ray method, encompassing both the sub-barrier and above barrier regions, viz., ElabE_{lab}= 7-24 MeV. Two separate experiments were performed, one for the above barrier region (ElabE_{lab}= 11-24 MeV) and another for the below barrier region (ElabE_{lab}= 7-10 MeV). The results were compared with our previously measured fusion cross section for the 7^7Li+28^{28}Si system. We observed enhancement of fusion cross section at sub-barrier regions for both 6^6Li and 7^7Li, but yield was substantially larger for 6^6Li. However, for well above barrier regions, similar type of suppression was identified for both the systems.Comment: 8 pages, 6 figures, as accepted for publication in Eur.Phys.J.

    Gain-through-filtering enables tuneable frequency comb generation in passive optical resonators

    Get PDF
    Optical frequency combs (OFCs), consisting of a set of phase-locked, equally spaced laser frequency lines, have enabled a great leap in precision spectroscopy and metrology since seminal works of HĂ€nsch et al. Nowadays, OFCs are cornerstones of a wealth of further applications ranging from chemistry and biology to astrophysics and including molecular fingerprinting and light detection and ranging (LIDAR) systems, among others. Driven passive optical resonators constitute the ideal platform for OFC generation in terms of compactness and low energy footprint. We propose here a technique for the generation of OFCs with a tuneable repetition rate in externally driven optical resonators based on the gain-through-filtering process, a simple and elegant method, due to asymmetric spectral filtering on one side of the pump wave. We demonstrate a proof-of-concept experimental result in a fibre resonator, pioneering a new technique that does not require specific engineering of the resonator dispersion to generate frequency-agile OFCs

    Quantum cascade laser frequency stabilisation at the sub-Hz level

    Full text link
    Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species

    Laser spectroscopy for breath analysis : towards clinical implementation

    Get PDF
    Detection and analysis of volatile compounds in exhaled breath represents an attractive tool for monitoring the metabolic status of a patient and disease diagnosis, since it is non-invasive and fast. Numerous studies have already demonstrated the benefit of breath analysis in clinical settings/applications and encouraged multidisciplinary research to reveal new insights regarding the origins, pathways, and pathophysiological roles of breath components. Many breath analysis methods are currently available to help explore these directions, ranging from mass spectrometry to laser-based spectroscopy and sensor arrays. This review presents an update of the current status of optical methods, using near and mid-infrared sources, for clinical breath gas analysis over the last decade and describes recent technological developments and their applications. The review includes: tunable diode laser absorption spectroscopy, cavity ring-down spectroscopy, integrated cavity output spectroscopy, cavity-enhanced absorption spectroscopy, photoacoustic spectroscopy, quartz-enhanced photoacoustic spectroscopy, and optical frequency comb spectroscopy. A SWOT analysis (strengths, weaknesses, opportunities, and threats) is presented that describes the laser-based techniques within the clinical framework of breath research and their appealing features for clinical use.Peer reviewe
    • 

    corecore