3,481 research outputs found

    Computer Algebra meets Finite Elements: an Efficient Implementation for Maxwell's Equations

    Full text link
    We consider the numerical discretization of the time-domain Maxwell's equations with an energy-conserving discontinuous Galerkin finite element formulation. This particular formulation allows for higher order approximations of the electric and magnetic field. Special emphasis is placed on an efficient implementation which is achieved by taking advantage of recurrence properties and the tensor-product structure of the chosen shape functions. These recurrences have been derived symbolically with computer algebra methods reminiscent of the holonomic systems approach.Comment: 16 pages, 1 figure, 1 table; Springer Wien, ISBN 978-3-7091-0793-

    Elimination of leakage in GaN-on-diamond

    Get PDF
    The use of chemical vapor deposition diamond as a substrate for gallium nitride (GaN) to form GaN- on-diamond has the potential to allow for higher linear power densities in GaN high electron mobility transistors (HEMTs). The increase in GaN HEMT power density on diamond has been limited to date by the electrical leakage in GaN-on-diamond substrates. In this paper we show that to eliminate buffer leakage in silicon based GaN-on- diamond, you have to completely remove the transition layers used to grow high quality GaN on the original host silicon. By completely removing the transition layers in GaN-on-diamond, we demonstrated buffer leakage comparable to the leakage in GaN on silicon carbide

    EGRET Observations of the Diffuse Gamma-Ray Emission in Orion: Analysis Through Cycle 6

    Get PDF
    We present a study of the high-energy diffuse emission observed toward Orion by the Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma-Ray Observatory. The total exposure by EGRET in this region has increased by more than a factor of two since a previous study. A simple model for the diffuse emission adequately fits the data; no significant point sources are detected in the region studied (l=195l = 195^\circ to 220220^\circ and b=25to10b = -25^\circ to -10^\circ) in either the composite dataset or in two separate groups of EGRET viewing periods considered. The gamma-ray emissivity in Orion is found to be (1.65±0.11)×1026ssr1(1.65 \pm 0.11) \times 10^{-26} {s sr}^{-1} for E > 100 MeV, and the differential emissivity is well-described as a combination of contributions from cosmic-ray electrons and protons with approximately the local density. The molecular mass calibrating ratio is N(H2)/WCO=(1.35±0.15)×1020cm2(Kkm/s)1N(H_2)/W_{CO} = (1.35 \pm 0.15) \times 10^{20} cm^{-2} (K km/s)^{-1}.Comment: 16 pages, including 5 figures. 3 Tables as three separate files. Latex document, needs AASTEX style files. Accepted for publication in Ap

    Influence of Context on Item Parameters in Forced-Choice Personality Assessments

    Get PDF
    A fundamental assumption in computerized adaptive testing (CAT) is that item parameters are invariant with respect to context – items surrounding the administered item. This assumption, however, may not hold in forced-choice (FC) assessments, where explicit comparisons are made between items included in the same block. We empirically examined the influence of context on item parameters by comparing parameter estimates from two FC instruments. The first instrument was compiled of blocks of three items, whereas in the second, the context was manipulated by adding one item to each block, resulting in blocks of four. The item parameter estimates were highly similar. However, a small number of significant deviations were observed, confirming the importance of context when designing adaptive FC assessments. Two patterns of such deviations were identified, and methods to reduce their occurrences in a FC CAT setting were proposed. It was shown that with a small proportion of violations of the parameter invariance assumption, score estimation remained stable

    Comparative ergonomic workflow and user experience analysis of MRI versus fluoroscopy-guided vascular interventions:an iliac angioplasty exemplar case study

    Get PDF
    Purpose A methodological framework is introduced to assess and compare a conventional fluoroscopy protocol for peripheral angioplasty with a new magnetic resonant imaging (MRI)-guided protocol. Different scenarios were considered during interventions on a perfused arterial phantom with regard to time-based and cognitive task analysis, user experience and ergonomics. Methods Three clinicians with different expertise performed a total of 43 simulated common iliac angioplasties (9 fluoroscopic, 34 MRI-guided) in two blocks of sessions. Six different configurations for MRI guidance were tested in the first block. Four of them were evaluated in the second block and compared to the fluoroscopy protocol. Relevant stages’ durations were collected, and interventions were audio-visually recorded from different perspectives. A cued retrospective protocol analysis (CRPA) was undertaken, including personal interviews. In addition, ergonomic constraints in the MRI suite were evaluated. Results Significant differences were found when comparing the performance between MRI configurations versus fluoroscopy. Two configurations [with times of 8.56 (0.64) and 9.48 (1.13) min] led to reduce procedure time for MRI guidance, comparable to fluoroscopy [8.49 (0.75) min]. The CRPA pointed out the main influential factors for clinical procedure performance. The ergonomic analysis quantified musculoskeletal risks for interventional radiologists when utilising MRI. Several alternatives were suggested to prevent potential low-back injuries. Conclusions This work presents a step towards the implementation of efficient operational protocols for MRI-guided procedures based on an integral and multidisciplinary framework, applicable to the assessment of current vascular protocols. The use of first-user perspective raises the possibility of establishing new forms of clinical training and education

    Localization properties of driven disordered one-dimensional systems

    Full text link
    We generalize the definition of localization length to disordered systems driven by a time-periodic potential using a Floquet-Green function formalism. We study its dependence on the amplitude and frequency of the driving field in a one-dimensional tight-binding model with different amounts of disorder in the lattice. As compared to the autonomous system, the localization length for the driven system can increase or decrease depending on the frequency of the driving. We investigate the dependence of the localization length with the particle's energy and prove that it is always periodic. Its maximum is not necessarily at the band center as in the non-driven case. We study the adiabatic limit by introducing a phenomenological inelastic scattering rate which limits the delocalizing effect of low-frequency fields.Comment: Accepted for publication in European Physical Journal

    Early vocabulary development in children with bilateral cochlear implants

    Get PDF
    BackgroundChildren with unilateral cochlear implants (CIs) may have delayed vocabulary development for an extended period after implantation. Bilateral cochlear implantation is reported to be associated with improved sound localization and enhanced speech perception in noise. This study proposed that bilateral implantation might also promote early vocabulary development. Knowledge regarding vocabulary growth and composition in children with bilateral CIs and factors associated with it may lead to improvements in the content of early speech and language intervention and family counselling. AimsTo analyse the growth of early vocabulary and its composition during the first year after CI activation and to investigate factors associated with vocabulary growth. Methods & ProceduresThe participants were 20 children with bilateral CIs (12 boys; eight girls; mean age at CI activation = 12.9 months). Vocabulary size was assessed with the Finnish version of the MacArthur Communicative Development Inventories (CDI) Infant Form and compared with normative data. Vocabulary composition was analysed in relation to vocabulary size. Growth curve modelling was implemented using a linear mixed model to analyse the effects of the following variables on early vocabulary growth: time, gender, maternal education, residual hearing with hearing aids, age at first hearing aid fitting and age at CI activation. Outcomes & ResultsDespite clear vocabulary growth over time, children with bilateral CIs lagged behind their age norms in receptive vocabulary during the first 12 months after CI activation. In expressive vocabulary, 35% of the children were able to catch up with their age norms, but 55% of the children lagged behind them. In receptive and expressive vocabularies of 1-20 words, analysis of different semantic categories indicated that social terms constituted the highest proportion. Nouns constituted the highest proportion in vocabularies of 101-400 words. The proportion of verbs remained below 20% and the proportion of function words and adjectives remained below 10% in the vocabularies of 1-400 words. There was a significant main effect of time, gender, maternal education and residual hearing with hearing aids before implantation on early receptive vocabulary growth. Time and residual hearing with hearing aids had a significant main effect also on expressive vocabulary growth. Conclusions & ImplicationsVocabulary development of children with bilateral CIs may be delayed. Thus, early vocabulary development needs to be assessed carefully in order to provide children and families with timely and targeted early intervention for vocabulary acquisition.Peer reviewe

    Signature of effective mass in crackling noise asymmetry

    Full text link
    Crackling noise is a common feature in many dynamic systems [1-9], the most familiar instance of which is the sound made by a sheet of paper when crumpled into a ball. Although seemingly random, this noise contains fundamental information about the properties of the system in which it occurs. One potential source of such information lies in the asymmetric shape of noise pulses emitted by a diverse range of noisy systems [8-12], but the cause of this asymmetry has lacked explanation [1]. Here we show that the leftward asymmetry observed in the Barkhausen effect [2] - the noise generated by the jerky motion of domain walls as they interact with impurities in a soft magnet - is a direct consequence of a magnetic domain wall's negative effective mass. As well as providing a means of determining domain wall effective mass from a magnet's Barkhausen noise our work suggests an inertial explanation for the origin of avalanche asymmetries in crackling noise phenomena more generally.Comment: 13 pages, 4 figures, to appear in Nature Physic
    corecore