5,556 research outputs found

    Distinguishing Oceans of Water from Magma on Mini-Neptune K2-18b

    Get PDF
    Mildly irradiated mini-Neptunes have densities potentially consistent with them hosting substantial liquid-water oceans ("Hycean" planets). The presence of CO2 and simultaneous absence of ammonia (NH3) in their atmospheres has been proposed as a fingerprint of such worlds. JWST observations of K2-18b, the archetypal Hycean, have found the presence of CO2 and the depletion of NH3 to 4 μm region, where CO2 and CO features dominate: magma ocean models suggest a systematically lower CO2/CO ratio than estimated from free-chemistry retrieval, indicating that deeper observations of this spectral region may be able to distinguish between oceans of liquid water and magma on mini-Neptunes

    A cost analysis of robotic vs. video-assisted thoracic surgery: The impact of the learning curve and the COVID-19 pandemic

    Get PDF
    IntroductionRobot-assisted thoracoscopic surgery (RATS) is an alternative to video-assessed thoracoscopic surgery (VATS) for the treatment of lung cancer but concern exists regarding the high associated costs. The COVID-19 pandemic added further financial pressure to healthcare systems. This study investigated the impact of the learning curve on the cost-effectiveness of RATS lung resection and the financial impact of the COVID-19 pandemic on a RATS program.MethodsPatients undergoing RATS lung resection between January 2017 and December 2020 were prospectively followed. A matched cohort of VATS cases were analyzed in parallel. The first 100 and most recent 100 RATS cases performed at our institution were compared to assess the learning curve. Cases performed before and after March 2020 were compared to assess the impact of the COVID-19 pandemic. A comprehensive cost analysis of multiple theatre and postoperative data points was performed using Stata statistics package (v14.2).Results365 RATS cases were included. Median cost per procedure was £7,167 and theatre cost accounted for 70%. Major contributing factors to overall cost were operative time and postoperative length of stay. Cost per case was £640 less after passing the learning curve (p < 0.001) largely due to reduced operative time. Comparison of a post-learning curve RATS subgroup matched to 101 VATS cases revealed no significant difference in theatre costs between the two techniques. Overall cost of RATS lung resections performed before and during the COVID-19 pandemic were not significantly different. However, theatre costs were significantly cheaper (£620/case; p < 0.001) and postoperative costs were significantly more expensive (£1,221/case; p = 0.018) during the pandemic.DiscussionPassing the learning curve is associated with a significant reduction in the theatre costs associated with RATS lung resection and is comparable with the cost of VATS. This study may underestimate the true cost benefit of passing the learning curve due to the effect of the COVID-19 pandemic on theatre costs. The COVID-19 pandemic made RATS lung resection more expensive due to prolonged hospital stay and increased readmission rate. The present study offers some evidence that the initial increased costs associated with RATS lung resection may be gradually offset as a program progresses

    Operative time and outcome of enhanced recovery after surgery after laparoscopic colorectal surgery

    Get PDF
    Background and Objectives: Combining laparoscopy and enhanced recovery provides benefit to short-term outcomes after colorectal surgery. Advances in training and techniques have allowed surgeons to operate on cases that are technically challenging and associated with prolonged operative time. Laparoscopic techniques improve the outcome of enhanced recovery after colorectal surgery; however, there are no specifications on the effect of prolonged operations on the outcome. The objective was to elucidate the impact of prolonged surgery and blood loss on the outcome of enhanced recovery after surgery after laparoscopic colorectal surgery. Methods: Four-hundred patients who underwent elective colorectal resection on enhanced recovery after surgery in Yeovil District Hospital between 2002 and 2009 were retrospectively reviewed. Delayed discharge was defined as a prolonged length of stay beyond the mean in this series (≥8 days). Results: Three-hundred eighty-five patients were included. Median operative time was 180 minutes with a median blood loss of 100 mL. Conversion was not associated with a prolonged length of stay. Operative time and blood loss correlated with length of stay in a stepwise fashion. There were 2 cutoff points of operative time at 160 minutes and 300 minutes (5 hours), where risk of prolonged stay increased significantly (odds ratio [OR] = 2.02; 95% confidence interval [CI], 1.05-3.90; P= 027), and blood loss of >500 mL (OR = 3.114; 95% CI, 1.501-6.462, P =.002). Conclusions: Total operative timing impacts negatively on the outcome of enhanced recovery after laparoscopic colorectal resections with increased risk of delayed discharge seen after ~2.5 hours and 5-hour duration. © 2014 by JSLS, Journal of the Society of Laparoendoscopic Surgeons

    Spectral line width decrease in the solar corona: resonant energy conversion from Alfv{\'e}n to acoustic waves

    Get PDF
    Observations reveal an increase with height of the line width of several coronal spectral lines probably caused by outwardly propagating Alfv{\'e}n waves. However, the spectral line width sometimes shows a sudden decrease at a height 0.1-0.2 R, where the ratio of sound to Alfven speeds may approach unity. Qualitative analysis shows that the resonant energy conversion from Alfven to acoustic waves near the region of the corona where the plasma β\beta approaches unity may explain the observed spectral line width reduction.Comment: 4 pages, 3 figure

    Ultra-bright and efficient single photon generation based on N-V centres in nanodiamonds on a solid immersion lens

    Get PDF
    Single photons are fundamental elements for quantum information technologies such as quantum cryptography, quantum information storage and optical quantum computing. Colour centres in diamond have proven to be stable single photon sources and thus essential components for reliable and integrated quantum information technology. A key requirement for such applications is a large photon flux and a high efficiency. Paying tribute to various attempts to maximise the single photon flux we show that collection efficiencies of photons from colour centres can be increased with a rather simple experimental setup. To do so we spin-coated nanodiamonds containing single nitrogen-vacancy colour centres on the flat surface of a ZrO2 solid immersion lens. We found stable single photon count rates of up to 853 kcts/s at saturation under continuous wave excitation while having excess to more than 100 defect centres with count rates from 400 kcts/s to 500 kcts/s. For a blinking defect centre we found count rates up to 2.4 Mcts/s for time intervals of several ten seconds. It seems to be a general feature that very high rates are accompanied by a blinking behaviour. The overall collection efficiency of our setup of up to 4.2% is the highest yet reported for N-V defect centres in diamond. Under pulsed excitation of a stable emitter of 10 MHz, 2.2% of all pulses caused a click on the detector adding to 221 kcts/s thus opening the way towards diamond based on-demand single photon sources for quantum applications

    Candidate plasma biomarkers for predicting ascending aortic aneurysm in bicuspid aortic valve disease.

    Get PDF
    BACKGROUND: Bicuspid aortic valve (BAV) disease is the most common congenital cardiac abnormality affecting 1-2% of the population and is associated with a significantly increased risk of ascending aortic aneurysm. However, predicting which patients will develop aneurysms remains a challenge. This pilot study aimed to identify candidate plasma biomarkers for monitoring ascending aortic diameter and predicting risk of future aneurysm in BAV patients. METHODS: Plasma samples were collected pre-operatively from BAV patients undergoing aortic valve surgery. Maximum ascending aortic diameter was measured on pre-operative transoesophageal echocardiography. Maximum diameter ≥ 45 mm was classified as aneurysmal. Sequential Window Acquisition of all THeoretical Mass Spectra (SWATH-MS), an advanced mass spectrometry technique, was used to identify and quantify all proteins within the samples. Protein abundance and aortic diameter were correlated using logistic regression. Levene's test was used to identify proteins demonstrating low abundance variability in the aneurysmal patients (consistent expression in disease), and high variability in the non-aneurysmal patients (differential expression between 'at risk' and not 'at risk' patients). RESULTS: Fifteen plasma samples were collected (seven non-aneurysmal and 8 aneurysmal BAV patients). The mean age of the patients was 55.5 years and the majority were female (10/15, 67%). Four proteins (haemoglobin subunits alpha, beta and delta and mannan-binding lectin serine protease) correlated significantly with maximal ascending aortic diameter (p < 0.05, r = 0.5-0.6). Five plasma proteins demonstrated significantly lower variability in the aneurysmal group and may indicate increased risk of aneurysm in non-aneurysmal patients (DNA-dependent protein kinase catalytic subunit, lumican, tetranectin, gelsolin and cartilage acidic protein 1). A further 7 proteins were identified only in the aneurysmal group (matrin-3, glucose-6-phosphate isomerase, coactosin-like protein, peptidyl-prolyl cis-trans isomerase A, golgin subfamily B member 1, myeloperoxidase and 2'-deoxynucleoside 5'-phosphate N-hydrolase 1). CONCLUSIONS: This study is the first to identify candidate plasma biomarkers for predicting aortic diameter and risk of future aneurysm in BAV patients. It provides valuable pilot data and proof of principle that could be used to design a large-scale prospective investigation. Ultimately, a more affordable 'off-the-shelf' follow-on blood assay could then be developed in place of SWATH-MS, for use in the healthcare setting

    The role of particle, energy and momentum losses in 1D simulations of divertor detachment

    Get PDF
    A new 1D divertor plasma code, SD1D, has been used to examine the role of recombination, radiation, and momentum exchange in detachment. Neither momentum or power losses by themselves are found to be sufficient to produce a reduction in target ion flux in detachment (flux rollover); radiative power losses are required to a) limit and reduce the ionization source and b) access low-target temperature, T_target, conditions for volumetric momentum losses. Recombination is found to play little role at flux rollover, but as T_target drops to temperatures around 1eV, it becomes a strong ion sink. In the case where radiative losses are dominated by hydrogen, the detachment threshold is identified as a minimum gradient of the energy cost per ionisation with respect to T_target. This is also linked to thresholds in T_target and in the ratio of upstream pressure to power flux. A system of determining the detached condition is developed such that the divertor solution at a given T_target (or lack of one) is determined by the simultaneous solution of two equations for target ion current - one dependent on power losses and the other on momentum. Depending on the detailed momentum and power loss dependence on temperature there are regions of T_target where there is no solution and the plasma 'jumps' from high to low T_target states. The novel analysis methods developed here provide an intuitive way to understand complex detachment phenomena, and can potentially be used to predict how changes in the seeding impurity used or recycling aspects of the divertor can be utilised to modify the development of detachment

    The role of particle, energy and momentum losses in 1D simulations of divertor detachment

    Get PDF
    A new 1D divertor plasma code, SD1D, has been used to examine the role of recombination, radiation, and momentum exchange in detachment. Neither momentum or power losses by themselves are found to be sufficient to produce a reduction in target ion flux in detachment (flux rollover); radiative power losses are required to a) limit and reduce the ionization source and b) access low-target temperature, T_target, conditions for volumetric momentum losses. Recombination is found to play little role at flux rollover, but as T_target drops to temperatures around 1eV, it becomes a strong ion sink. In the case where radiative losses are dominated by hydrogen, the detachment threshold is identified as a minimum gradient of the energy cost per ionisation with respect to T_target. This is also linked to thresholds in T_target and in the ratio of upstream pressure to power flux. A system of determining the detached condition is developed such that the divertor solution at a given T_target (or lack of one) is determined by the simultaneous solution of two equations for target ion current - one dependent on power losses and the other on momentum. Depending on the detailed momentum and power loss dependence on temperature there are regions of T_target where there is no solution and the plasma 'jumps' from high to low T_target states. The novel analysis methods developed here provide an intuitive way to understand complex detachment phenomena, and can potentially be used to predict how changes in the seeding impurity used or recycling aspects of the divertor can be utilised to modify the development of detachment
    corecore