3,777 research outputs found

    Complete stereocontrol in the synthesis of macrocyclic lanthanide complexes:direct formation of enantiopure systems for circularly polarised luminescence applications

    Get PDF
    Mono-C-substitution of the 1,4,7-triazacyclononane ring induces formation of single enantiomers of Eu(III) complexes with nonadentate N6O3 ligands. The absolute configuration of each complex is determined by the stereogenicity of the C-substituent, revealed by comparison of the sign and sequence of CPL transitions for a series of complexes

    Calibration of myocardial T2 and T1 against iron concentration.

    Get PDF
    BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies

    Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan.

    Get PDF
    BACKGROUND: There is a need to standardise non-invasive measurements of liver iron concentrations (LIC) so clear inferences can be drawn about body iron levels that are associated with hepatic and extra-hepatic complications of iron overload. Since the first demonstration of an inverse relationship between biopsy LIC and liver magnetic resonance (MR) using a proof-of-concept T2* sequence, MR technology has advanced dramatically with a shorter minimum echo-time, closer inter-echo spacing and constant repetition time. These important advances allow more accurate calculation of liver T2* especially in patients with high LIC. METHODS: Here, we used an optimised liver T2* sequence calibrated against 50 liver biopsy samples on 25 patients with transfusional haemosiderosis using ordinary least squares linear regression, and assessed the method reproducibility in 96 scans over an LIC range up to 42 mg/g dry weight (dw) using Bland-Altman plots. Using mixed model linear regression we compared the new T2*-LIC with R2-LIC (Ferriscan) on 92 scans in 54 patients with transfusional haemosiderosis and examined method agreement using Bland-Altman approach. RESULTS: Strong linear correlation between ln(T2*) and ln(LIC) led to the calibration equation LIC = 31.94(T2*)-1.014. This yielded LIC values approximately 2.2 times higher than the proof-of-concept T2* method. Comparing this new T2*-LIC with the R2-LIC (Ferriscan) technique in 92 scans, we observed a close relationship between the two methods for values up to 10 mg/g dw, however the method agreement was poor. CONCLUSIONS: New calibration of T2* against liver biopsy estimates LIC in a reproducible way, correcting the proof-of-concept calibration by 2.2 times. Due to poor agreement, both methods should be used separately to diagnose or rule out liver iron overload in patients with increased ferritin

    Design of high-magnetic field gradient sources for controlling magnetically induced flow of ferrofluids in microfluidic systems

    Get PDF
    The use of miniature electromagnets for ferrofluid-actuated liquid dispensing into microfluidic channels has been investigated by numerical simulations using the finite element method and measurements of fluid displacement and flow rate. The simulations illustrate the effect of structural and geometrical parameters of single and paired solenoid coils on the magnetic force experienced by the ferrofluid. Dual solenoids were used for extended fluid displacement. Ferrofluid positioning and flow rates were controlled also by using a solenoid with an iron core. The experimental measurements of fluidflow in capillaries were used to validate the modeling calculations. The results can be used as a basis for the development of on-chip ferrofluid-based devices integrated with microfluidic architectures

    Mapping Nanostructural Variations in Silk by Secondary Electron Hyperspectral Imaging

    Get PDF
    Nanostructures underpin the excellent properties of silk. Although the bulk nanocomposition of silks has been well studied, direct evidence of the spatial variation of nanocrystalline (ordered) and amorphous (disordered) structures has remained elusive. Here we demonstrate that secondary electron hyperspectral imaging, can be exploited for direct imaging of hierarchical structures in carbon based materials which cannot be revealed by any other standard characterization methods. Applying this technique to silks from domesticated (Bombyx mori) and wild (Antheraea mylitta) silkworms, we report a variety of previously unseen features which highlight the local interplay between ordered and disordered structures. We conclude that our technique is able to differentiate composition on the nanoscale and enables in-depth studies into the relationship between morphology and performance of these complex biopolymer systems

    Criminal and Noncriminal Psychopathy: The Devil is in the Detail

    Get PDF
    Brooks, NS ORCiD: 0000-0003-1784-099XPsychopathy is prevalent and problematic in criminal populations, but is also found to be present in noncriminal populations. In 1992, Robert Hare declared that psychopaths may also “be found in the boardroom”, which has since been followed by an interest in the issue of noncriminal, or even successful, psychopathy. In this chapter, the paradox of criminal and noncriminal psychopathy is discussed with specific attention given to the similarities and differences that account for psychopathic personality across contexts. That psychopathy is a condition typified by a constellation of traits and behaviours requires wider research across diverse populations, and thus the streams of research related to criminal and noncriminal psychopathy are presented and the implications of these contrasting streams are explored

    Right ventricular volumes and function in thalassemia major patients in the absence of myocardial iron overload

    Get PDF
    <p>Abstract</p> <p>Aim</p> <p>We aimed to define reference ranges for right ventricular (RV) volumes, ejection fraction (EF) in thalassemia major patients (TM) without myocardial iron overload.</p> <p>Methods and results</p> <p>RV volumes, EF and mass were measured in 80 TM patients who had no myocardial iron overload (myocardial T2* > 20 ms by cardiovascular magnetic resonance). All patients were receiving deferoxamine chelation and none had evidence of pulmonary hypertension or other cardiovascular comorbidity. Forty age and sex matched healthy non-anemic volunteers acted as controls. The mean RV EF was higher in TM patients than controls (males 66.2 ± 4.1% vs 61.6 ± 6%, p = 0.0009; females 66.3 ± 5.1% vs 62.6 ± 6.4%, p = 0.017), which yielded a raised lower threshold of normality for RV EF in TM patients (males 58.0% vs 50.0% and females 56.4% vs 50.1%). RV end-diastolic volume index was higher in male TM patients (mean 98.1 ± 17.3 mL vs 88.4 ± 11.2 mL/m2, p = 0.027), with a higher upper limit (132 vs 110 mL/m2) but this difference was of borderline significance for females (mean 86.5 ± 13.6 mL vs 80.3 ± 12.8 mL/m2, p = 0.09, with upper limit of 113 vs 105 mL/m2). The cardiac index was raised in TM patients (males 4.8 ± 1.0 L/min vs 3.4 ± 0.7 L/min, p < 0.0001; females 4.5 ± 0.8 L/min vs 3.2 ± 0.8 L/min, p < 0.0001). No differences in RV mass index were identified.</p> <p>Conclusion</p> <p>The normal ranges for functional RV parameters in TM patients with no evidence of myocardial iron overload differ from healthy non-anemic controls. The new reference RV ranges are important for determining the functional effects of myocardial iron overload in TM patients.</p

    Processing-Induced Disorder in Pharmaceutical Materials

    Get PDF
    This chapter focuses on the major types of pharmaceutical processing methods that have been widely reported to produce disordered material either intentionally or unintentionally. Milling is one of the most frequently used unit operations used by the pharmaceutical industry for reducing the particle size of solids. Thermal processing techniques are mainly used for controlling or improving the release and the subsequent bioavailability of an active pharmaceutical ingredient (API). Techniques such as melt-mixing, spray-congealing, sintering, melt-granulation, and hot-melt extrusion (HME) have developed and evolved rapidly for large-scale pharmaceutical production. Solvent-evaporation-based methods are important processing techniques for both raw materials, such as crystallization of the raw drug, and formulation manufacturing in the pharmaceutical industry. The chapter discusses the processing that can potentially induce the formation of the disordered state during the manufacture of formulations. The widely used solvent-evaporation-based processing techniques in pharmaceutical formulation production include spray-drying, freeze-drying, film casting, and film coating
    corecore