819 research outputs found

    ОБМЕН СООБЩЕНИЯМИ В МИКС-СЕТЯХ

    Get PDF
    Рассмотрена идея Д.Чаума организации анонимной микс-сети с пересылкой сообщений через каскад миксов (передаточных узлов) и последовательным шифрованием всех промежуточных результатов. Описаны задачи, решаемые миксами в ходе обеспечения анонимности связи, обговариваются проблемы ее безопасности

    Medical students’ views about having different types of problem-based learning tutors

    Get PDF
    Background At Norwich Medical School, Year 3 or 4 medical students taking a year out of the 5-year undergraduate MBBS degree to do a master’s degree in clinical education worked as near-peer problem-based learning (PBL) tutors for students in Year 2. Peer-assisted learning has been shown to benefit both peer tutors and tutees; in this study, experiences of students with near-peer PBL tutors were compared to students with other types of PBL tutor. Methods Using existing student evaluation data, we compared student views about PBL tutor performance, PBL group functioning, and overall satisfaction with PBL learning experience according to whether their PBL tutor/s were (1) a single near-peer tutor (later-year MB BS student), (2) a single staff tutor, (3) multiple staff tutors, or (4) multiple newly qualified doctor tutors. Results Results indicated that students’ evaluation of tutor performance was more positive for near-peer PBL tutors compared to both groups of staff tutors for most areas evaluated. Additionally, students’ evaluation of overall satisfaction with PBL was more positive for near-peer PBL tutors compared to multiple staff tutors. Tutor performance for multiple staff tutors was evaluated less positively compared to both single staff and multiple newly qualified doctor groups. But there were no statistically significant differences between the four groups regarding PBL group functioning. Conclusion Near-peer PBL tutors perform comparably or better to staff PBL tutors in salient measures of tutor performance and group functioning. We conclude that medical students find near-peer PBL tutors to be an acceptable addition to the PBL tutor workforce

    Release of Soluble Receptors for Tumor Necrosis Factor in Clinical Sepsis and Experimental Endotoxemia

    Get PDF
    To assess the role of tumor necrosis factor (TNF) in the appearance of soluble TNF receptors (sTNFRs), 20 consecutive patients with a clinical diagnosis of sepsis were studied as were 7 chimpanzees after administration of endotoxin (4 ng/kg) with or without pentoxifylline. The patients had markedly elevated serum levels of sTNFR-p55 and sTNFR-p75 compared with healthy controls (P < .0001 for both receptors). The levels of both soluble receptors correlated with simultaneously measured immunoreactive TNF concentrations (p55: r = .63, P < .01; p75: r = .69, P < .001). In the chimpanzees, endotoxin induced subsequent rises in the serum concentrations ofTNF and sTNFRs. Although pentoxifylline reduced the TNF response to intravenous endotoxin to 20% (P < .05), the appearance of sTNFRs was only moderately inhibited (sTNFR-p55 to 79% on average, P < .05; sTNFR-p75 to 77%, P = .12). These results indicate that TNF either does not play an important role in the appearance of sTNFRs in systemic infection or that a small amount ofTNF remaining in the circulation after some bacterial challenges is sufficient to preserve the secretion of its soluble receptor

    Laboratory testing in patients treated with direct oral anticoagulants: a practical guide for clinicians

    Get PDF
    Click to hear Dr Baglin's perspective on the role of the laboratory in treatment with new oral anticoagulants SUMMARY: One of the key benefits of the direct oral anticoagulants (DOACs) is that they do not require routine laboratory monitoring. Nevertheless, assessment of DOAC exposure and anticoagulant effects may become useful in various clinical scenarios. The five approved DOACs (apixaban, betrixaban, dabigatran etexilate, edoxaban and rivaroxaban) have different characteristics impacting assay selection and the interpretation of results. This article provides an updated overview on (i) which test to use (and their advantages and limitations), (ii) when to assay DOAC levels, (iii) how to interpret the results relating to bleeding risk, emergency situations and perioperative management, and (iv) what is the impact of DOACs on routine and specialized coagulation assays. Assays for anti-Xa or anti-IIa activity are the preferred methods when quantitative information is useful, although the situations in which to test for DOAC levels are still debated. Different reagent sensitivities and variabilities in laboratory calibrations impact assay results. International calibration standards for all specific tests for each DOAC are needed to reduce the inter-laboratory variability and allow inter-study comparisons. The impact of the DOACs on hemostasis testing may cause false-positive or false-negative results; however, these can be minimized by using specific assays and collecting blood samples at trough concentrations. Finally, prospective clinical trials are needed to validate the safety and efficacy of proposed laboratory thresholds in relation to clinical decisions. We offer recommendations on the tests to use for measuring DOACs and practical guidance on laboratory testing to help patient management and avoid diagnostic errors. ispartof: Journal of Thrombosis and Haemostasis vol:16 issue:2 pages:209-219 ispartof: location:England status: publishe

    Remote Non-invasive Stereoscopic Imaging of Blood Vessels: First In-vivo Results of a New Multispectral Contrast Enhancement Technology

    Get PDF
    We describe a contactless optical technique selectively enhancing superficial blood vessels below variously pigmented intact human skin by combining images in different spectral bands. Two CMOS-cameras, with apochromatic lenses and dual-band LED-arrays, simultaneously streamed Left (L) and Right (R) image data to a dual-processor PC. Both cameras captured color images within the visible range (VIS, 400–780 nm) and grey-scale images within the near infrared range (NIR, 910–920 nm) by sequentially switching between LED-array emission bands. Image-size-settings of 1280 × 1024 for VIS & 640 × 512 for NIR produced 12 cycles/s (1 cycle = 1 VIS L&R-pair + 1 NIR L&R-pair). Decreasing image-size-settings (640 × 512 for VIS and 320 × 256 for NIR) increased camera-speed to 25 cycles/s. Contrasts from below the tissue surface were algorithmically distinguished from surface shadows, reflections, etc. Thus blood vessels were selectively enhanced and back-projected into the stereoscopic VIS-color-image using either a 3D-display or conventional shutter glasses. As a first usability reconnaissance we applied this custom-built mobile stereoscopic camera for several clinical settings: • blood withdrawal; • vein inspection in dark skin; • vein detection through iodide; • varicose vein and nevi pigmentosum inspection. Our technique improves blood vessel visualization compared to the naked eye, and supports depth perception

    Analysis of blood coagulation in mice: pre-analytical conditions and evaluation of a home-made assay for thrombin-antithrombin complexes

    Get PDF
    BACKGROUND: The use of mouse models for the study of thrombotic disorders has gained increasing importance. Methods for measurement of coagulation activation in mice are, however, scarce. The primary aim of this study was to develop a specific mouse thrombin-antithrombin (TAT) ELISA for measurement of coagulation activation and to compare it with two commercially available assays for human TAT complexes. In addition, we aimed to improve methods for mouse plasma anticoagulation and preparation. METHODS AND RESULTS: First, for the measurement of TAT-complexes in plasma a mouse specific TAT-ELISA was developed using rabbit polyclonal antibodies raised against mouse thrombin and rat antithrombin, respectively. This ELISA detected an increase in TAT levels in a mouse model of endotoxemia. Two commercial human TAT ELISAs appeared to be less specific for mouse thrombin-rat antithrombin complexes. Second, to prevent clotting of mouse blood sodium citrate was either mixed with blood during collection in a syringe or was injected intravenously immediately prior to blood collection. Intravenous sodium citrate completely inhibited blood coagulation resulting in plasma with consistently low TAT levels. Sodium citrate mixed with blood during collection resulted in increased TAT levels in 4 out of 16 plasma samples. Third, heparinase was added to plasma samples after in vivo injection of different heparin doses to test its neutralizing effect. Heparinase neutralized up to a 20 U of heparin/mouse and resulted in accurate APTT and factor VIII determinations. CONCLUSION: These procedures and reagents for plasma preparation and coagulation testing will improve studies on thrombotic disorders in mice

    Self-assembly in solution of a reversible comb-shaped supramolecular polymer

    Get PDF
    We report a single step synthesis of a polyisobutene with a bis-urea moiety in the middle of the chain. In low polarity solvents, this polymer self-assembles by hydrogen bonding to form a combshaped polymer with a central hydrogen bonded backbone and polyisobutene arms. The comb backbone can be reversibly broken, and consequently, its length can be tuned by changing the solvent, the concentration or the temperature. Moreover, we have proved that the bulkiness of the side-chains have a strong influence on both the self-assembly pattern and the length of the backbone. Finally, the density of arms can be reduced, by simply mixing with a low molar mass bis-urea

    Experimental Bearing Capacity Determination of Bonded Rock Bolts

    Get PDF
    Import 26/02/2015Diplomová práce se zabývá únosností tmelených horninových svorníků a jejím experimentální stanovením. Tato práce analyzuje a poukazuje na možné způsoby porušení, které vznikají zatížením v těsné blízkosti svorníkové tyče a to především v prstenci tmele na kontaktech svorník – tmel a tmel – hornina. V teoretické části byl navržen způsob měření a stanovení pevnostních a deformačních charakteristik tahem zatížených tmelených svorníků napodobujících zatížení v kořenové délce svorníkové výztuže. V praktické části byly pak navržené postupy uskutečněny sérií laboratorních zkoušek. Výstupem z provedených zkoušek je pracovně-deformační charakteristika tmelené svorníkové výztuže zvoleného testovaného materiálu.The thesis focuses on the bearing capacity of bonded rock bolts and experimental determination of this capacity. Possible ways of failure, which is caused by the load near the rock bolt, especially in the circular ring of the grout and between the rock bolt - the grout and between the grout - the rock, are analysed. The theoretical part includes design of measuring and assessment of strength and deformation characteristics on drawn rock bolts as it simulates the load in the root length of bolt reinforcement. This theory was applied in the laboratory tests and presents the practical part of the thesis. In conclusion, the load - deformation characteristics of bonded rock bolt reinforcement made from chosen material are stated.224 - Katedra geotechniky a podzemního stavitelstvívýborn
    corecore