28 research outputs found

    Dual-Energy CT Material Decomposition:The Value in the Detection of Lymph Node Metastasis from Breast Cancer

    Get PDF
    Purpose: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. Materials and Methods: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. Results: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p &lt; 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. Conclusions: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.</p

    Dual-Energy CT Material Decomposition:The Value in the Detection of Lymph Node Metastasis from Breast Cancer

    Get PDF
    Purpose: To evaluate the diagnostic performance of a dual-energy computed tomography (DECT)-based material decomposition algorithm for iodine quantification and fat fraction analysis to detect lymph node metastases in breast cancer patients. Materials and Methods: 30 female patients (mean age, 63.12 ± 14.2 years) diagnosed with breast cancer who underwent pre-operative chest DECT were included. To establish a reference standard, the study correlated histologic repots after lymphadenectomy or confirming metastasis in previous/follow-up examinations. Iodine concentration and fat fraction were determined through region-of-interest measurements on venous DECT iodine maps. Receiver operating characteristic curve analysis was conducted to identify the optimal threshold for differentiating between metastatic and non-metastatic lymph nodes. Results: A total of 168 lymph nodes were evaluated, divided into axillary (metastatic: 46, normal: 101) and intramammary (metastatic: 10, normal: 11). DECT-based fat fraction values exhibited significant differences between metastatic (9.56 ± 6.20%) and non-metastatic lymph nodes (41.52 ± 19.97%) (p &lt; 0.0001). Absolute iodine concentrations showed no significant differences (2.25 ± 0.97 mg/mL vs. 2.08 ± 0.97 mg/mL) (p = 0.7999). The optimal fat fraction threshold for diagnosing metastatic lymph nodes was determined to be 17.75%, offering a sensitivity of 98% and a specificity of 94%. Conclusions: DECT fat fraction analysis emerges as a promising method for identifying metastatic lymph nodes, overcoming the morpho-volumetric limitations of conventional CT regarding lymph node assessment. This innovative approach holds potential for improving pre-operative lymph node evaluation in breast cancer patients, offering enhanced diagnostic accuracy.</p

    Accuracy and time efficiency of a novel deep learning algorithm for Intracranial Hemorrhage detection in CT Scans

    Get PDF
    Purpose: To evaluate a deep learning-based pipeline using a Dense-UNet architecture for the assessment of acute intracranial hemorrhage (ICH) on non-contrast computed tomography (NCCT) head scans after traumatic brain injury (TBI). Materials and methods: This retrospective study was conducted using a prototype algorithm that evaluated 502 NCCT head scans with ICH in context of TBI. Four board-certified radiologists evaluated in consensus the CT scans to establish the standard of reference for hemorrhage presence and type of ICH. Consequently, all CT scans were independently analyzed by the algorithm and a board-certified radiologist to assess the presence and type of ICH. Additionally, the time to diagnosis was measured for both methods. Results: A total of 405/502 patients presented ICH classified in the following types: intraparenchymal (n = 172); intraventricular (n = 26); subarachnoid (n = 163); subdural (n = 178); and epidural (n = 15). The algorithm showed high diagnostic accuracy (91.24%) for the assessment of ICH with a sensitivity of 90.37% and specificity of 94.85%. To distinguish the different ICH types, the algorithm had a sensitivity of 93.47% and a specificity of 99.79%, with an accuracy of 98.54%. To detect midline shift, the algorithm had a sensitivity of 100%. In terms of processing time, the algorithm was significantly faster compared to the radiologist’s time to first diagnosis (15.37 ± 1.85 vs 277 ± 14 s, p &lt; 0.001). Conclusion: A novel deep learning algorithm can provide high diagnostic accuracy for the identification and classification of ICH from unenhanced CT scans, combined with short processing times. This has the potential to assist and improve radiologists’ ICH assessment in NCCT scans, especially in emergency scenarios, when time efficiency is needed.</p

    Standardization of Dual-Energy CT Iodine Uptake of the Abdomen and Pelvis:Defining Reference Values in a Big Data Cohort

    Get PDF
    Background: To establish dual-energy-derived iodine density reference values in abdominopelvic organs in a large cohort of healthy subjects. Methods: 597 patients who underwent portal venous phase dual-energy CT scans of the abdomen were retrospectively enrolled. Iodine distribution maps were reconstructed, and regions of interest measurements were placed in abdominal and pelvic structures to obtain absolute iodine values. Subsequently, normalization of the abdominal aorta was conducted to obtain normalized iodine ratios. The values obtained were subsequently analyzed and differences were investigated in subgroups defined by sex, age and BMI. Results: Overall mean iodine uptake values and normalized iodine ratios ranged between 0.31 and 6.08 mg/mL and 0.06 and 1.20, respectively. Women exhibited higher absolute iodine concentration across all organs. With increasing age, normalized iodine ratios mostly tend to decrease, being most significant in the uterus, prostate, and kidneys (p &lt; 0.015). BMI was the parameter less responsible for variations in iodine concentrations; normal weighted patients demonstrated higher values of both absolute and normalized iodine. Conclusions: Iodine concentration values and normalized iodine ratios of abdominal and pelvic organs reveal significant gender-, age-, and BMI-related differences, underscoring the necessity to integrate these variables into clinical practice.</p

    Optimization of window settings for coronary arteries assessment using spectral CT-derived virtual monoenergetic imaging

    Get PDF
    Purpose: To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. Material and methods: 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. Results: VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p &lt; 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. Conclusion: Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.</p

    Using Routinely Collected Administrative Data in Public Health Research: Geocoding Alcohol Outlet Data

    Get PDF
    We describe our process of geocoding alcohol outlets to create a national longitudinal exposure dataset for Wales, United Kingdom from 2006 to 2011. We investigated variation in the availability of data items and the quality of alcohol outlet addresses held within unitary authorities. We used a standard geocoding method augmented with a manual matching procedure to achieve a fully spatially referenced dataset. We found higher quality addresses are held for outlets based in urban areas, resulting in the automatic geocoding of 68 % of urban outlets, compared to 48 % in rural areas. Missing postcodes and a lack of address structure contributed to a lower geocoding proportion. An urban rural bias was removed with the development of a manual matching procedure. Only one-half of the unitary authorities provided data on on/off sales and opening times, which are important availability factors. The resulting outlet dataset is suitable for contributing to the evidence-base of alcohol availability and alcohol-related harm. Local government should be encouraged to use standardised data fields, including addresses, to enable accurate geocoding of alcohol outlets and facilitate research that aims to prevent alcohol-related harm. Standardising data collection would enable efficient secondary data reuse using record linkage techniques, allowing the retrospective creation and evaluation of population-based natural experiments to provide evidence for policy and practice

    Longevity and relationships with children: the importance of the parental role

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Social networks predict longevity across societies but specific mechanisms are largely unknown. The aim of this work was to examine the role of children in the longevity of elderly men and women in a cohort of community dwelling elderly people in Spain.</p> <p>Methods</p> <p>The data were taken from the "Aging in Leganes" cohort study with 15 years of follow-up. The baseline population was an age- and sex-stratified random sample of community dwelling people over 65 living in Leganés (Madrid) in 1993. Poor relationship with at least one child, emotional support and the perceived roles elders play in the lives of their children, extended family, spouse and friends were assessed at baseline. Cox proportional hazards models were fit to investigate the effects of social roles variables on longevity, adjusting for a wide range of socioeconomic, behavioural and health covariates.</p> <p>Results</p> <p>In the fully adjusted model, having a poor relationship with at least one child increased mortality by 30%. Elderly persons who felt their role in their children's lives was important (HR = 0.70; 95% CI 0.54; 0.91) had a lower mortality risk than those who felt they played a small role. Feeling loved and listened to by one's children did not have an effect on survival. Maintaining an important role in the extended family was also significantly associated with survival.</p> <p>Conclusion</p> <p>In this Mediterranean population, maintaining an important role in the lives of one's children is associated with survival. Functions of social networks related to meaning of life and different forms of social support may have important effects on mortality, and these functions may vary across cultures according to family norms and values.</p

    Biomechanical Assessment of Liver Integrity: Prospective Evaluation of Mechanical Versus Acoustic MR Elastography

    Get PDF
    BACKGROUND: Magnetic resonance elastography (MRE) can quantify tissue biomechanics noninvasively, including pathological hepatic states like metabolic dysfunction-associated steatohepatitis. PURPOSE: To compare the performance of 2D/3D-MRE using the gravitational (GT) transducer concept with the current commercial acoustic (AC) solution utilizing a 2D-MRE approach. Additionally, quality index markers (QIs) were proposed to identify image pixels with sufficient quality for reliably estimating tissue biomechanics. STUDY TYPE: Prospective. POPULATION: One hundred seventy participants with suspected or confirmed liver disease (median age, 57 years [interquartile range (IQR), 46-65]; 66 females), and 11 healthy volunteers (median age, 31 years [IQR, 27-34]; 5 females). FIELD STRENGTH/SEQUENCE: Participants were scanned twice at 1.5 T and 60 Hz vibration frequency: first, using AC-MRE (2D-MRE, spin-echo EPI sequence, 11 seconds breath-hold), and second, using GT-MRE (2D- and 3D-MRE, gradient-echo sequence, 14 seconds breath-hold). ASSESSMENT: Image analysis was performed by four independent radiologists and one biomedical engineer. Additionally, superimposed analytic plane shear waves of known wavelength and attenuation at fixed shear modulus were used to propose pertinent QIs. STATISTICAL TESTS: Spearman's correlation coefficient (r) was applied to assess the correlation between modalities. Interreader reproducibility was evaluated using Bland-Altman bias and reproducibility coefficients. P-values <0.05 were considered statistically significant. RESULTS: Liver stiffness quantified via GT-2D/3D correlated well with AC-2D (r ≥ 0.89 [95% CI: 0.85-0.92]) and histopathological grading (r ≥ 0.84 [95% CI: 0.72-0.91]), demonstrating excellent agreement in Bland-Altman plots and between readers (κ ≥ 0.86 [95% CI: 0.81-0.91]). However, GT-2D showed a bias in overestimating stiffness compared to GT-3D. Proposed QIs enabled the identification of pixels deviating beyond 10% from true stiffness based on a combination of total wave amplitude, temporal sinusoidal nonlinearity, and wave signal-to-noise ratio for GT-3D. CONCLUSION: GT-MRE represents an alternative to AC-MRE for noninvasive liver tissue characterization. Both GT-2D and 3D approaches correlated strongly with the established commercial approach, offering advanced capabilities in abdominal imaging compared to AC-MRE. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2

    Suicidal Behavior and Alcohol Abuse

    Get PDF
    Suicide is an escalating public health problem, and alcohol use has consistently been implicated in the precipitation of suicidal behavior. Alcohol abuse may lead to suicidality through disinhibition, impulsiveness and impaired judgment, but it may also be used as a means to ease the distress associated with committing an act of suicide. We reviewed evidence of the relationship between alcohol use and suicide through a search of MedLine and PsychInfo electronic databases. Multiple genetically-related intermediate phenotypes might influence the relationship between alcohol and suicide. Psychiatric disorders, including psychosis, mood disorders and anxiety disorders, as well as susceptibility to stress, might increase the risk of suicidal behavior, but may also have reciprocal influences with alcohol drinking patterns. Increased suicide risk may be heralded by social withdrawal, breakdown of social bonds, and social marginalization, which are common outcomes of untreated alcohol abuse and dependence. People with alcohol dependence or depression should be screened for other psychiatric symptoms and for suicidality. Programs for suicide prevention must take into account drinking habits and should reinforce healthy behavioral patterns

    Diagnosis of Uric Acid-Based Urine Sedimentation in the Bladder Using Dual-Energy CT

    Get PDF
    Urine sedimentation in the bladder can occur in various circumstances and can lead to urinary obstruction/stasis with associated pain. It is usually diagnosed with an ultrasound; however, CT is also used to assess the amount and to further check for urinary stones. Depending on the composition, urine sedimentation and stones can be treated medically by alkalinisation of the urine with potassium sodium hydrogen citrate in the case of uric acid-based sedimentation/stones. Due to technical developments and improved material differentiation and characterisation in CT imaging, dual-energy CT allows for differentiation of uric acid from calcium, which can be used for sedimentation/stone composition analysis. Subsequently, treatment decisions can be made based on the findings in dual-energy CT
    corecore