370 research outputs found
A sound card based multi-channel frequency measurement system
For physical processes which express themselves as a frequency, for example
magnetic field measurements using optically-pumped alkali-vapor magnetometers,
the precise extraction of the frequency from the noisy signal is a classical
problem. We describe herein a frequency measurement system based on an
inexpensive commercially available computer sound card coupled with a software
single-tone estimator which reaches Cram\'er--Rao limited performance, a
feature which commercial frequency counters often lack. Characterization of the
system and examples of its successful application to magnetometry are
presented.Comment: 4 pages, 3 figures, 1 tabl
Recommended from our members
Driver performance under simulated and actual driving conditions: validity and orthogonality
This study contrasted the performance of drivers under actual and simulated driving conditions, in order to assess the validity of the simulators and test the hypothesis that driving is composed of largely orthogonal sub-tasks. Thirty experienced drivers completed an on-road driving test and drove two different simulators, each simulator drive comprising seven difficulty-moderated driving scenarios. Between-simulator contrasts revealed largely absolute validity, the anticipated effects of increased difficulty within driving scenarios, but weak relationships between performance of different driving scenarios. On-road driving was reliably assessed by a nationally-recognised expert driving assessor, as reflected by standard statistical measures of reliability and consistency. However, on-road driving revealed relatively little cross-category correlation of on-road driving errors, or between on-road and simulator driving. Thus, despite the compelling evidence of absolute and relative validity within and between simulators, there is little evidence of criterion validity (i.e. relationship to on road driving, as assessed by the expert assessor). Moreover, the study provides strong evidence for orthogonality in the driving task- driving comprises large numbers of relatively separate tasks
A high-sensitivity laser-pumped Mx magnetometer
Abstract.: We discuss the design and performance of a laser-pumped cesium vapor magnetometer in the Mx configuration. The device will be employed in the control and stabilization of fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. We have determined the intrinsic sensitivity of the device to be 15 fT in a 1 Hz bandwidth, limited by technical laser noise. In the shot noise limit the magnetometer can reach a sensitivity of 10 fT in a 1 Hz bandwidth. We have used the device to study the fluctuations of a stable magnetic field in a multi-layer magnetic shield for integration times in the range of 2-100 seconds. The residual fluctuations for times up to a few minutes are traced back to the instability of the power supply used to generate the fiel
Listeriolysin S, a Novel Peptide Haemolysin Associated with a Subset of Lineage I Listeria monocytogenes
peer-reviewedStreptolysin S (SLS) is a bacteriocin-like haemolytic and cytotoxic virulence factor that plays a key role in the virulence of Group A Streptococcus (GAS), the causative agent of pharyngitis, impetigo, necrotizing fasciitis and streptococcal toxic shock syndrome. Although it has long been thought that SLS and related peptides are produced by GAS and related streptococci only, there is evidence to suggest that a number of the most notorious Gram-positive pathogenic bacteria, including Listeria monocytogenes, Clostridium botulinum and Staphylococcus aureus, produce related peptides. The distribution of the L. monocytogenes cluster is particularly noteworthy in that it is found exclusively among a subset of lineage I strains; i.e., those responsible for the majority of outbreaks of listeriosis. Expression of these genes results in the production of a haemolytic and cytotoxic factor, designated Listeriolysin S, which contributes to virulence of the pathogen as assessed by murine- and human polymorphonuclear neutrophil–based studies. Thus, in the process of establishing the existence of an extended family of SLS-like modified virulence peptides (MVPs), the genetic basis for the enhanced virulence of a proportion of lineage I L. monocytogenes may have been revealed.Work is funded by the Irish Government under the National Development Plan, through a Science Foundation Ireland Investigator award to CH, PR and PC (06/IN.1/B98)
Sensitivity of double resonance alignment magnetometers
We present an experimental study of the intrinsic magnetometric sensitivity
of an optical/rf-frequency double resonance magnetometer in which linearly
polarized laser light is used in the optical pumping and detection processes.
We show that a semi-empirical model of the magnetometer can be used to describe
the magnetic resonance spectra. Then, we present an efficient method to predict
the optimum operating point of the magnetometer, i.e., the light power and rf
Rabi frequency providing maximum magnetometric sensitivity. Finally, we apply
the method to investigate the evolution of the optimum operating point with
temperature. The method is very efficient to determine relaxation rates and
thus allowed us to determine the three collisional disalignment cross sections
for the components of the alignment tensor. Both first and second harmonic
signals from the magnetometer are considered and compared
A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells
We have manufactured more than 250 nominally identical paraffin-coated Cs
vapor cells (30 mm diameter bulbs) for multi-channel atomic magnetometer
applications. We describe our dedicated cell characterization apparatus. For
each cell we have determined the intrinsic longitudinal, \sGamma{01}, and
transverse, \sGamma{02}, relaxation rates. Our best cell shows
\sGamma{01}/2\pi\approx 0.5 Hz, and \sGamma{02}/2\pi\approx 2 Hz. We find a
strong correlation of both relaxation rates which we explain in terms of
reservoir and spin exchange relaxation. For each cell we have determined the
optimal combination of rf and laser powers which yield the highest sensitivity
to magnetic field changes. Out of all produced cells, 90% are found to have
magnetometric sensitivities in the range of 9 to 30 fTHz. Noise analysis shows
that the magnetometers operated with such cells have a sensitivity close to the
fundamental photon shot noise limit
Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins
Physics at the Planck scale could be revealed by looking for tiny violations
of fundamental symmetries in low energy experiments. In 2008, a sensitive test
of the isotropy of the Universe using has been performed with stored ultracold
neutrons (UCN), this is the first clock-comparison experiment performed with
free neutrons. During several days we monitored the Larmor frequency of neutron
spins in a weak magnetic field using the Ramsey resonance technique. An
non-zero cosmic axial field, violating rotational symmetry, would induce a
daily variation of the precession frequency. Our null result constitutes one of
the most stringent tests of Lorentz invariance to date.Comment: proceedings of the PNCMI2010 conferenc
The specificity and patterns of staining in human cells and tissues of p16INK4a antibodies demonstrate variant antigen binding
The validity of the identification and classification of human cancer using antibodies to detect biomarker proteins depends upon antibody specificity. Antibodies that bind to the tumour-suppressor protein p16INK4a are widely used for cancer diagnosis and research. In this study we examined the specificity of four commercially available anti-p16INK4a antibodies in four immunological applications. The antibodies H-156 and JC8 detected the same 16 kDa protein in western blot and immunoprecipitation tests, whereas the antibody F-12 did not detect any protein in western blot analysis or capture a protein that could be recognised by the H-156 antibody. In immunocytochemistry tests, the antibodies JC8 and H-156 detected a predominately cytoplasmic localised antigen, whose signal was depleted in p16INK4a siRNA experiments. F-12, in contrast, detected a predominately nuclear located antigen and there was no noticeable reduction in this signal after siRNA knockdown. Furthermore in immunohistochemistry tests, F-12 generated a different pattern of staining compared to the JC8 and E6H4 antibodies. These results demonstrate that three out of four commercially available p16INK4a antibodies are specific to, and indicate a mainly cytoplasmic localisation for, the p16INK4a protein. The F-12 antibody, which has been widely used in previous studies, gave different results to the other antibodies and did not demonstrate specificity to human p16INK4a. This work emphasizes the importance of the validation of commercial antibodies, aside to the previously reported use, for the full verification of immunoreaction specificity
Admission of advanced lung cancer patients to intensive care unit: A retrospective study of 76 patients
<p>Abstract</p> <p>Background</p> <p>Criteria for admitting patients with incurable diseases to the medical intensive care unit (MICU) remain unclear and have ethical implications.</p> <p>Methods</p> <p>We retrospectively evaluated MICU outcomes and identified risk factors for MICU mortality in consecutive patients with advanced lung cancer admitted to two university-hospital MICUs in France between 1996 and 2006.</p> <p>Results</p> <p>Of 76 included patients, 49 had non-small cell lung cancer (stage IIIB n = 20; stage IV n = 29). In 60 patients, MICU admission was directly related to the lung cancer (complication of cancer management, n = 30; cancer progression, n = 14; and lung-cancer-induced diseases, n = 17). Mechanical ventilation was required during the MICU stay in 57 patients. Thirty-six (47.4%) patients died in the MICU. Three factors were independently associated with MICU mortality: use of vasoactive agents (odds ratio [OR] 6.81 95% confidence interval [95%CI] [1.77-26.26], p = 0.005), mechanical ventilation (OR 6.61 95%CI [1.44-30.5], p = 0.015) and thrombocytopenia (OR 5.13; 95%CI [1.17-22.5], p = 0.030). In contrast, mortality was lower in patients admitted for a complication of cancer management (OR 0.206; 95%CI [0.058-0.738], p = 0.015). Of the 27 patients who returned home, four received specific lung cancer treatment after the MICU stay.</p> <p>Conclusions</p> <p>Patients with acute complications of treatment for advanced lung cancer may benefit from MCIU admission. Further studies are necessary to assess outcomes such as quality of life after MICU discharge.</p
- …