432 research outputs found

    Weak localization in ferromagnetic (Ga,Mn)As nanostructures

    Get PDF
    We report on the observation of weak localization in arrays of (Ga,Mn)As nanowires at millikelvin temperatures. The corresponding phase coherence length is typically between 100 nm and 200 nm at 20 mK. Strong spin-orbit interaction in the material is manifested by a weak anti-localization correction around zero magnetic field.Comment: 5 pages, 3 figure

    The influence of tDCS on perceived bouncing/streaming

    Get PDF
    Processing ambiguous situations is a constant challenge in everyday life and sensory input from different modalities needs to be integrated to form a coherent mental representation on the environment. The bouncing/streaming illusion can be studied to provide insights into the ambiguous perception and processing of multi-modal environments. In short, the likelihood of reporting bouncing rather than streaming impressions increases when a sound coincides with the moment of overlap between two moving disks. Neuroimaging studies revealed that the right posterior parietal cortex is crucial in cross-modal integration and is active during the bouncing/streaming illusion. Consequently, in the present study, we used transcranial direct current stimulation to stimulate this brain area. In the active stimulation conditions, a 9 cm2 electrode was positioned over the P4-EEG position and the 35 cm2 reference positioned over the left upper arm. The stimulation lasted 15 min. Each participant did the bouncing/streaming task three times: before, during and after anodal or sham stimulation. In a sample of N = 60 healthy, young adults, we found no influence of anodal tDCS. Bayesian analysis showed strong evidence against tDCS effects. There are two possible explanations for the finding that anodal tDCS over perceptual areas did not modulate multimodal integration. First, upregulation of multimodal integration is not possible using tDCS over the PPC as the integration process already functions at maximum capacity. Second, prefrontal decision-making areas may have overruled any modulated input from the PPC as it may not have matched their decision-making criterion and compensated for the modulation

    Differential functional benefits of ultra highfield MR systems within the language network

    Get PDF
    Several investigations have shown limitations of fMRI reliability with the current standard field strengths. Improvement is expected from ultra highfield systems but studies on possible benefits for cognitive networks are lacking. Here we provide an initial investigation on a prominent and clinically highly-relevant cognitive function: language processing in individual brains. 26 patients evaluated for presurgical language localization were investigated with a standardized overt language fMRI paradigm on both 3T and 7T MR scanners. During data acquisition and analysis we made particular efforts to minimize effects not related to static magnetic field strength differences. Six measures relevant for functional activation showed a large dissociation between essential language network nodes: although in Wernicke's area 5/6 measures indicated a benefit of ultra highfield, in Broca's area no comparison was significant. The most important reason for this discrepancy was identified as being an increase in susceptibility-related artifacts in inferior frontal brain areas at ultra high field. We conclude that functional UHF benefits are evident, however these depend crucially on the brain region investigated and the ability to control local artifacts

    High contrast optical imaging of companions: the case of the brown dwarf binary HD-130948BC

    Full text link
    High contrast imaging at optical wavelengths is limited by the modest correction of conventional near-IR optimized AO systems.We take advantage of new fast and low-readout-noise detectors to explore the potential of fast imaging coupled to post-processing techniques to detect faint companions to stars at small separations. We have focused on I-band direct imaging of the previously detected brown dwarf binary HD130948BC,attempting to spatially resolve the L2+L2 benchmark system. We used the Lucky-Imaging instrument FastCam at the 2.5-m Nordic Telescope to obtain quasi diffraction-limited images of HD130948 with ~0.1" resolution.In order to improve the detectability of the faint binary in the vicinity of a bright (I=5.19 \pm 0.03) solar-type star,we implemented a post-processing technique based on wavelet transform filtering of the image which allows us to strongly enhance the presence of point-like sources in regions where the primary halo dominates. We detect for the first time the BD binary HD130948BC in the optical band I with a SNR~9 at 2.561"\pm 0.007" (46.5 AU) from HD130948A and confirm in two independent dataset that the object is real,as opposed to time-varying residual speckles.We do not resolve the binary, which can be explained by astrometric results posterior to our observations that predict a separation below the NOT resolution.We reach at this distance a contrast of dI = 11.30 \pm 0.11, and estimate a combined magnitude for this binary to I = 16.49 \pm 0.11 and a I-J colour 3.29 \pm 0.13. At 1", we reach a detectability 10.5 mag fainter than the primary after image post-processing. We obtain on-sky validation of a technique based on speckle imaging and wavelet-transform processing,which improves the high contrast capabilities of speckle imaging.The I-J colour measured for the BD companion is slightly bluer, but still consistent with what typically found for L2 dwarfs(~3.4-3.6).Comment: accepted in A\&

    A direct and differential imaging search for sub-stellar companions to epsilon Indi A

    Full text link
    We have carried out a direct and differential imaging search for sub-stellar companions to eps Indi A using the adaptive optics system NACO at the ESO VLT. The observations were carried out in September 2004 with NACO/SDI as well as with NACO's S27 camera in the H and Ks filters. The SDI data cover an area of \~2.8" around eps Indi A. No detection was achieved in the inner neighbourhood down to 53 Mj (5 sigma confidence level) at a separation > 0.4" (1.45 AU) and down to 21 Mj for separations > 1.3" (4.7 AU). To cover a wider field of view, observations with the S27 camera and a coronagraphic mask were obtained. We detected a faint source at a separation of (7.3 +/- 0.1)" and a position angle of (302.9 +/- 0.8) degree. The photometry for the candidate companion yields m(H)=(16.45 +/- 0.04)mag and m(Ks) = (15.41 +/- 0.06)mag, respectively. Those magnitudes and the resulting color (H-Ks) = (1.04 +/- 0.07)mag fit best to a spectral type of L5 - L9.5 if it is bound. Observations done with HST/NICMOS by M. Endl have shown the source to be a background object.Comment: 6 pages, 5 figures, accepted by A&

    Automated processing of oceanic bubble images for measuring bubble size distributions underneath breaking waves

    Get PDF
    Accurate in situ measurements of oceanic bubble size distributions beneath breaking waves are needed for a better understanding of air–sea gas transfer and aerosol production processes. To achieve this goal, a novel high-resolution optical instrument for imaging oceanic bubbles was designed and built in 2013 for the High Wind Gas Exchange Study (HiWinGS) campaign in the North Atlantic Ocean. The instrument is able to operate autonomously and can continuously capture high-resolution images at 15 frames per second over an 8-h deployment. The large number of images means that it is essential to use an automated processing algorithm to process these images. This paper describes an automated algorithm for processing oceanic images based on a robust feature extraction technique. The main advantages of this robust algorithm are it is significantly less sensitive to the noise and insusceptible to the background changes in illumination, can extract circular bubbles as small as one pixel (approximately 20 μm) in radius accurately, has low computing time (approximately 5 seconds per image), and is simple to implement. The algorithm was successfully used to analyze a large number of images (850 000 images) from deployment in the North Atlantic Ocean as part of the HiWinGS campaign in 2013

    Evaluation of a ferrozine based autonomous in situ lab-on-chip analyzer for dissolved iron species in coastal waters

    Get PDF
    The trace metal iron (Fe) is an essential micronutrient for phytoplankton growth and limits, or co-limits primary production across much of the world's surface ocean. Iron is a redox sensitive element, with Fe(II) and Fe(III) co-existing in natural waters. Whilst Fe(II) is the most soluble form, it is also transient with rapid oxidation rates in oxic seawater. Measurements of Fe(II) are therefore preferably undertaken in situ. For this purpose an autonomous wet chemical analyzer based on lab-on-chip technology was developed for the in situ determination of the concentration of dissolved (<0.45 μm) Fe species (Fe(II) and labile Fe) suitable for deployments in a wide range of aquatic environments. The spectrophotometric approach utilizes a buffered ferrozine solution and a ferrozine/ascorbic acid mixture for Fe(II) and labile Fe(III) analyses, respectively. Diffusive mixing, color development and spectrophotometric detection take place in three separate flow cells with different lengths such that the analyzer can measure a broad concentration range from low nM to several μM of Fe, depending on the desired application. A detection limit of 1.9 nM Fe was found. The microfluidic analyzer was tested in situ for nine days in shallow waters in the Kiel Fjord (Germany) along with other sensors as a part of the SenseOCEAN EU-project. The analyzer's performance under natural conditions was assessed with discrete samples collected and processed according to GEOTRACES protocol [acidified to pH < 2 and analyzed via inductively coupled plasma mass spectrometry (ICP-MS)]. The mechanical performance of the analyzer over the nine day period was good (consistent high precision of Fe(II) and Fe(III) standards with a standard deviation of 2.7% (n = 214) and 1.9% (n = 217), respectively, and successful completion of every programmed data point). However, total dissolved Fe was consistently low compared to ICP-MS data. Recoveries between 16 and 75% were observed, indicating that the analyzer does not measure a significant fraction of natural dissolved Fe species in coastal seawater. It is suggested that an acidification step would be necessary in order to ensure that the analyzer derived total dissolved Fe concentration is reproducible and consistent with discrete values

    How nanotechnology-enabled concepts could contribute to the prevention, diagnosis and therapy of bacterial infections

    Get PDF
    This viewpoint summarizes a selection of nanotechnology-based key concepts relevant to critical care medicine. It focuses on novel approaches for a trigger-dependent release of antimicrobial substances from degradable nano-sized carriers, the ultra-sensitive detection of analytes in body fluid samples by plasmonic and fluorescent nanoparticles, and the rapid removal of pathogens from whole blood using magnetic nanoparticles. The concepts presented here could significantly contribute to the prevention, diagnosis and therapy of bacterial infections in future and it is now our turn to bring them from the bench to the bedside

    Concepts of health and well-being in managers: An organizational study

    Get PDF
    Global changes and new managerial challenges require new concepts of health and well-being in organizational contexts. In the South African context, health and well-being of managers have gained relevance in organizations and in management sciences. International organizations, in particular, attempt to address the increasing demand for health care and the delivery of health services to their managers. Careful and appropriate health management requires research to evaluate context-specific health concepts and strategies. The purpose and aim of this article is to assess managerial concepts on health and well-being that could be used by the organization to contribute to managerial well-being by implementing health promotion according to managerial needs. At the same time, this article contributes to salutogenetic health research that is very rare with regard to the South African organizational management research

    Human Umbilical Cord Blood Cells Restore Brain Damage Induced Changes in Rat Somatosensory Cortex

    Get PDF
    Intraperitoneal transplantation of human umbilical cord blood (hUCB) cells has been shown to reduce sensorimotor deficits after hypoxic ischemic brain injury in neonatal rats. However, the neuronal correlate of the functional recovery and how such a treatment enforces plastic remodelling at the level of neural processing remains elusive. Here we show by in-vivo recordings that hUCB cells have the capability of ameliorating the injury-related impairment of neural processing in primary somatosensory cortex. Intact cortical processing depends on a delicate balance of inhibitory and excitatory transmission, which is disturbed after injury. We found that the dimensions of cortical maps and receptive fields, which are significantly altered after injury, were largely restored. Additionally, the lesion induced hyperexcitability was no longer observed in hUCB treated animals as indicated by a paired-pulse behaviour resembling that observed in control animals. The beneficial effects on cortical processing were reflected in an almost complete recovery of sensorimotor behaviour. Our results demonstrate that hUCB cells reinstall the way central neurons process information by normalizing inhibitory and excitatory processes. We propose that the intermediate level of cortical processing will become relevant as a new stage to investigate efficacy and mechanisms of cell therapy in the treatment of brain injury
    corecore