182 research outputs found

    Monotone Proofs of the Pigeon Hole Principle

    Get PDF
    Lecture Notes in Computer Science. Geneva, Switzerland, July 9-15

    Probabilistic modelling of tool unbalance during cutting of hard-heterogeneous materials: a case study in Ceramic Matrix Composites (CMCs)

    Get PDF
    Compared to other materials, CMCs display a unique high hardness and heterogeneous nature which are critically reflected during the drilling process where asymmetrical high forces are suffered by the tool, resulting in an unbalance of the drill bit. Hence, this study proposes a mechanistic approach where the hard nature resulting in high radial forces is analytically studied and coupled with a probabilistic model where the heterogeneous nature of CMCs is taken into consideration. This theoretical study results in an in-depth understanding of the loading unbalance occurring on different tool sizes during drilling of CMCs which can lead to a premature tool breakage. The nature of this unique force that is assumed in the theoretical approach to influence the cutting of hard-heterogeneous materials is experimentally validated by drilling a homogeneous and a heterogeneous hard ceramics, i.e. a monolithic SiC and a SiC/SiC CMC. Moreover, the model developed together the with drilling experiments with different tool diameters result in an understanding of why small tool diameters suffer a premature tool breakage when drilling difficult-to-machine CMCs

    Determining the fundamental failure modes in Ni-rich lithium ion battery cathodes

    Get PDF
    Challenges associated with in-service mechanical degradation of Li-ion battery cathodes has prompted a transition from polycrystalline to single crystal cathode materials. Whilst for single crystal materials, dislocation-assisted crack formation is assumed to be the dominating failure mechanism throughout battery life, there is little direct information about their mechanical behaviour, and mechanistic understanding remains elusive. Here, we demonstrated, using in situ micromechanical testing, direct measurement of local mechanical properties within LiNi0.8Mn0.1Co0.1O2 single crystalline domains. We elucidated the dislocation slip systems, their critical stresses, and how slip facilitate cracking. We then compared single crystal and polycrystal deformation behaviour. Our findings answer two fundamental questions critical to understanding cathode degradation: What dislocation slip systems operate in Ni-rich cathode materials? And how does slip cause fracture? This knowledge unlocks our ability to develop tools for lifetime prediction and failure risk assessment, as well as in designing novel cathode materials with increased toughness in-service

    PARSAR: Parallelisation of a chirp scaling algorithm SAR processor

    Get PDF
    A parallel SAR processor is presented in this paper. The target configuration is a cluster of UNIX workstations, available in most user sites. This fact allows to obtain an increased computing performance without the need of dedicated hardware investment.Peer ReviewedPostprint (published version

    Transiting exoplanets from the CoRoT space mission VIII. CoRoT-7b: the first Super-Earth with measured radius

    Get PDF
    We report the discovery of very shallow (DF/F = 3.4 10-4), periodic dips in the light curve of an active V = 11.7 G9V star observed by the CoRoT satellite, which we interpret as due to the presence of a transiting companion. We describe the 3-colour CoRoT data and complementary ground-based observations that support the planetary nature of the companion. Methods. We use CoRoT color information, good angular resolution ground-based photometric observations in- and out- of transit, adaptive optics imaging, near-infrared spectroscopy and preliminary results from Radial Velocity measurements, to test the diluted eclipsing binary scenarios. The parameters of the host star are derived from optical spectra, which were then combined with the CoRoT light curve to derive parameters of the companion. We examine carefully all conceivable cases of false positives, and all tests performed support the planetary hypothesis. Blends with separation larger than 0.40 arcsec or triple systems are almost excluded with a 8 10-4 risk left. We conclude that, as far as we have been exhaustive, we have discovered a planetary companion, named CoRoT-7b, for which we derive a period of 0.853 59 +/- 3 10-5 day and a radius of Rp = 1.68 +/- 0.09 REarth. Analysis of preliminary radial velocity data yields an upper limit of 21 MEarth for the companion mass, supporting the finding. CoRoT-7b is very likely the first Super-Earth with a measured radius.Comment: Accepted in Astronomy and Astrophysics; typos and language corrections; version sent to the printer w few upgrade

    Effects of adding Tiotropium or Aclidinium as triple therapy using impulse oscillometry in COPD

    Get PDF
    INTRODUCTION: Long-acting muscarinic antagonists confer improvements in spirometry when used in addition to inhaled corticosteroids and long-acting beta-agonists (ICS/LABA) in COPD. The dual objectives of this proof of concept study were to evaluate trough effects of tiotropium (TIO) or aclidinium (ACL) when used as triple therapy and to assess if impulse oscillometry (IOS) might be more sensitive than spirometry in detecting subtle differences in bronchodilator response. METHODS: Patients with moderate to severe COPD already taking ICS/LABA were randomized to receive add-on therapy in cross-over fashion with either TIO 18 µg od or ACL 322 µg bid for 2–3 weeks each. Measurements of IOS, spirometry, 6-min walk test, St George’s Respiratory Questionnaire (SGRQ) and Baseline/Transition Dyspnoea Index (TDI) were made at baseline and after chronic dosing at trough (12 h for ACL and 24 h for TIO), in addition to domiciliary diurnal spirometry. RESULTS: 13 patients were completed: mean age 69 years, FEV(1) 52 % predicted, FEV(1)/FVC 0.48, and R5 202 % predicted. There were no differences in any visit-based trough IOS or spirometry outcomes comparing TIO versus ACL. Resonant frequency but not total airway resistance at 5 Hz (R5) significantly improved from baseline with both treatments while peripheral airway resistance (R5–R20) significantly improved with ACL. Visit-based FEV(1), and forced and relaxed vital capacity were also significantly improved from baseline with both treatments. There were no significant differences in diurnal FEV(1) and FEV(6) profiles between treatments. 6-min walk distance and post-walk fatigue significantly improved from baseline with ACL, while post-walk dyspnea improved with TIO. SGRQ symptom score significantly improved to a similar degree with both treatments. TDI significantly improved with ACL versus TIO by 1.54 units. CONCLUSION: We observed comparable bronchodilator efficacy at trough with TIO and ACL when used as triple therapy in COPD, while IOS was no more sensitive than spirometry

    Efficacy and safety of once-daily aclidinium in chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: The long-term efficacy and safety of aclidinium bromide, a novel, long-acting muscarinic antagonist, were investigated in patients with moderate to severe chronic obstructive pulmonary disease (COPD). METHODS: In two double-blind, 52-week studies, ACCLAIM/COPD I (n=843) and II (n=804), patients were randomised to inhaled aclidinium 200 μg or placebo once-daily. Patients were required to have a post-bronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity ratio of ≤70% and FEV1<80% of the predicted value. The primary endpoint was trough FEV1 at 12 and 28 weeks. Secondary endpoints were health status measured by St George's Respiratory Questionnaire (SGRQ) and time to first moderate or severe COPD exacerbation. RESULTS: At 12 and 28 weeks, aclidinium improved trough FEV1 versus placebo in ACCLAIM/COPD I (by 61 and 67 mL; both p<0.001) and ACCLAIM/COPD II (by 63 and 59 mL; both p<0.001). More patients had a SGRQ improvement≥4 units at 52 weeks with aclidinium versus placebo in ACCLAIM/COPD I (48.1% versus 39.5%; p=0.025) and ACCLAIM/COPD II (39.0% versus 32.8%; p=0.074). The time to first exacerbation was significantly delayed by aclidinium in ACCLAIM/COPD II (hazard ratio [HR] 0.7; 95% confidence interval [CI] 0.55 to 0.92; p=0.01), but not ACCLAIM/COPD I (HR 1.0; 95% CI 0.72 to 1.33; p=0.9). Adverse events were minor in both studies. CONCLUSION: Aclidinium is effective and well tolerated in patients with moderate to severe COPD

    European Space Agency experiments on thermodiffusion of fluid mixtures in space

    Get PDF
    Abstract.: This paper describes the European Space Agency (ESA) experiments devoted to study thermodiffusion of fluid mixtures in microgravity environment, where sedimentation and convection do not affect the mass flow induced by the Soret effect. First, the experiments performed on binary mixtures in the IVIDIL and GRADFLEX experiments are described. Then, further experiments on ternary mixtures and complex fluids performed in DCMIX and planned to be performed in the context of the NEUF-DIX project are presented. Finally, multi-component mixtures studied in the SCCO project are detailed
    • …
    corecore