67 research outputs found
Mercury and antimony in wastewater: fate and treatment
It is important to understand the fate of Hg and Sb within the wastewater treatment process so as to examine potential treatment options and to ensure compliance with regulatory standards. The fate of Hg and Sb was investigated for an activated sludge process treatment works in the UK. Relatively high crude values (Hg 0.092 μg/L, Sb 1.73 μg/L) were observed at the works, whilst low removal rates within the primary (Hg 52.2 %, Sb 16.3 %) and secondary treatment stages (Hg 29.5 %, Sb −28.9 %) resulted in final effluent concentrations of 0.031 μg/L for Hg and 2.04 μg/L for Sb. Removal of Hg was positively correlated with suspended solids (SS) and chemical oxygen demand (COD) removal, whilst Sb was negatively correlated. Elevated final effluent Sb concentrations compared with crude values were postulated and were suggested to result from Sb present in returned sludge liquors. Kepner Tregoe (KT) analysis was applied to identify suitable treatment technologies. For Hg, chemical techniques (specifically precipitation) were found to be the most suitable whilst for Sb, adsorption (using granulated ferric hydroxide) was deemed most appropriate. Operational solutions, such as lengthening hydraulic retention time, and treatment technologies deployed on sludge liquors were also reviewed but were not feasible for implementation at the works
Coagulation–flocculation process with metal salts, synthetic polymers and biopolymers for the removal of trace metals (Cu, Pb, Ni, Zn) from municipal wastewater
To ensure compliance with regulatory standards, it is important to examine the potential of treatment technologies to enhance trace metal removal from wastewater. This study investigated the effectiveness of coagulation–flocculation at removing trace metals from humus effluent with ferric chloride (FeCl3), the synthetic polymer polyethyleneimine (PEI) and the biopolymers chitosan and floculan. Effluent samples were collected from a trickling filter treatment works operating in the UK and contained 21 ± 4 μg/L Cu, 0.8 ± 0.1 μg/L Pb, 4 ± 1 μg/L Ni and 43 ± 9 μg/L Zn. The influence of coagulant dosage and the velocity and time of the slow mixing stage were studied via a series of jar tests. Chitosan and PEI had a moderate effect on the removal of trace metals (≤ 35%). FeCl3 removed 48% Cu, 56% Pb and 41% Zn at the optimised dose of 0.10 mg/L. At the optimised dose of 0.25 mg/L, floculan removed 77% Cu, 68% Pb and 42% Zn. The dominant mechanism for particle removal by FeCl3 was enmeshment in the precipitates (i.e. sweep flocculation), whereas, for floculan, inter-particle bridging was the dominant removal mechanism. Overall, FeCl3 and floculan were found to be most effective at removing trace metals from wastewater
IROA: the International Register of Open Abdomen.
Actually the most common indications for Open Abdomen (OA) are trauma, abdominal sepsis, severe acute pancreatitis and more in general all those situations in which an intra-abdominal hypertension condition is present, in order to prevent the development of an abdominal compartment syndrome. The mortality and morbidity rate in patients undergone to OA procedures is still high. At present many studies have been published about the OA management and the progresses in survival rate of critically ill trauma and septic surgical patients. However several issues are still unclear and need more extensive studies. The definitions of indications, applications and methods to close the OA are still matter of debate. To overcome this lack of high level of evidence data about the OA indications, management, definitive closure and follow-up, the World Society of Emergency Surgery (WSES) promoted the International Register of Open Abdomen (IROA). The register will be held on a web platform (Clinical Registers®) through a dedicated web site: www.clinicalregisters.org. This will allow to all surgeons and physicians to participate from all around the world only by having a computer and a web connection. The IROA protocol has been approved by the coordinating center Ethical Committee (Papa Giovanni XXIII hospital, Bergamo, Italy). IROA has also been registered to ClinicalTrials.gov (ClinicalTrials.gov Identifier: NCT02382770)
Short-Term Daily Intake of Polydextrose Fiber Does Not Shorten Intestinal Transit Time in Constipated Adults: A Randomized Controlled Trial.
Chronic constipation (CC) remains a common gastrointestinal (GI) disorder that conveys a substantial healthcare burden. Expert guidelines recommend increasing fiber intake, yet the clinical evidence to support this needs strengthening for specific fibers. The aim was to evaluate changes in intestinal transit time and GI symptoms in CC patients who consumed polydextrose. In a randomized, double-blind, placebo-controlled trial, 128 adults with CC received 8 g or 12 g polydextrose, or placebo, daily for 4 weeks. Transit time, as primary outcome, was assessed by radiopaque marker distribution after 2-weeks intervention. Bowel habits, GI symptoms and quality of life (QOL) were assessed by questionnaire, including the Patient-Assessment of Constipation (PAC) Symptoms (SYM), and PAC-QOL. Following 2-weeks intervention, no reduction was seen in transit time in any group and following 2- or 4-weeks intervention, no improvements were seen in stool frequency or consistency in any group. After 2-weeks intervention with 8 g/day polydextrose an improvement was seen in the PAC-SYM rectal score (p = 0.041). After 4-weeks intervention both rectal (p = 0.049) and stool (p = 0.029) scores improved while improvement in the QOL satisfaction score did not reach significance (p = 0.071). Overall, the results suggest that 2-weeks consumption of 8 or 12 g/day polydextrose does not significantly improve physiological measures of gut function in CC adults. Longer term consumption may improve clinical measures, but further studies will be required to substantiate this.Nestec SA
Cohesin acetyltransferase Esco2 is a cell viability factor and is required for cohesion in pericentric heterochromatin
Genetic deletion of murine Esco2 (an acetylase known to establish cohesin during S-phase and genetically linked to Roberts syndrome) results in embryonic lethality that can be molecularly linked to novel and specific functions of Esco2 at pericentric heterochromatin
IROA : the International Register of Open Abdomen. An international effort to better understand the open abdomen: call for participants
Actually the most common indications for Open Abdomen (OA) are trauma, abdominal sepsis, severe acute pancreatitis and more in general all those situations in which an intra-abdominal hypertension condition is present, in order to prevent the development of an abdominal compartment syndrome. The mortality and morbidity rate in patients undergone to OA procedures is still high. At present many studies have been published about the OA management and the progresses in survival rate of critically ill trauma and septic surgical patients. However several issues are still unclear and need more extensive studies. The definitions of indications, applications and methods to close the OA are still matter of debate. To overcome this lack of high level of evidence data about the OA indications, management, definitive closure and follow-up, the World Society of Emergency Surgery (WSES) promoted the International Register of Open Abdomen (IROA). The register will be held on a web platform (Clinical Registers (R)) through a dedicated web site: www. clinicalregisters. org. This will allow to all surgeons and physicians to participate from all around the world only by having a computer and a web connection. The IROA protocol has been approved by the coordinating center Ethical Committee (Papa Giovanni XXIII hospital, Bergamo, Italy).Non peer reviewe
Upper limits on the strength of periodic gravitational waves from PSR J1939+2134
The first science run of the LIGO and GEO gravitational wave detectors
presented the opportunity to test methods of searching for gravitational waves
from known pulsars. Here we present new direct upper limits on the strength of
waves from the pulsar PSR J1939+2134 using two independent analysis methods,
one in the frequency domain using frequentist statistics and one in the time
domain using Bayesian inference. Both methods show that the strain amplitude at
Earth from this pulsar is less than a few times .Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo
Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July
200
Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers
We study frequency dependent (FD) input-output schemes for signal-recycling
interferometers, the baseline design of Advanced LIGO and the current
configuration of GEO 600. Complementary to a recent proposal by Harms et al. to
use FD input squeezing and ordinary homodyne detection, we explore a scheme
which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are
sub-optimal among all possible input-output schemes, provide a global noise
suppression by the power squeeze factor, while being realizable by using
detuned Fabry-Perot cavities as input/output filters. At high frequencies, the
two schemes are shown to be equivalent, while at low frequencies our scheme
gives better performance than that of Harms et al., and is nearly fully
optimal. We then study the sensitivity improvement achievable by these schemes
in Advanced LIGO era (with 30-m filter cavities and current estimates of
filter-mirror losses and thermal noise), for neutron star binary inspirals, and
for narrowband GW sources such as low-mass X-ray binaries and known radio
pulsars. Optical losses are shown to be a major obstacle for the actual
implementation of these techniques in Advanced LIGO. On time scales of
third-generation interferometers, like EURO/LIGO-III (~2012), with
kilometer-scale filter cavities, a signal-recycling interferometer with the FD
readout scheme explored in this paper can have performances comparable to
existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi
Search for gravitational wave bursts in LIGO's third science run
We report on a search for gravitational wave bursts in data from the three
LIGO interferometric detectors during their third science run. The search
targets subsecond bursts in the frequency range 100-1100 Hz for which no
waveform model is assumed, and has a sensitivity in terms of the
root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No
gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published
in Classical and Quantum Gravit
Quantum state preparation and macroscopic entanglement in gravitational-wave detectors
Long-baseline laser-interferometer gravitational-wave detectors are operating
at a factor of 10 (in amplitude) above the standard quantum limit (SQL) within
a broad frequency band. Such a low classical noise budget has already allowed
the creation of a controlled 2.7 kg macroscopic oscillator with an effective
eigenfrequency of 150 Hz and an occupation number of 200. This result, along
with the prospect for further improvements, heralds the new possibility of
experimentally probing macroscopic quantum mechanics (MQM) - quantum mechanical
behavior of objects in the realm of everyday experience - using
gravitational-wave detectors. In this paper, we provide the mathematical
foundation for the first step of a MQM experiment: the preparation of a
macroscopic test mass into a nearly minimum-Heisenberg-limited Gaussian quantum
state, which is possible if the interferometer's classical noise beats the SQL
in a broad frequency band. Our formalism, based on Wiener filtering, allows a
straightforward conversion from the classical noise budget of a laser
interferometer, in terms of noise spectra, into the strategy for quantum state
preparation, and the quality of the prepared state. Using this formalism, we
consider how Gaussian entanglement can be built among two macroscopic test
masses, and the performance of the planned Advanced LIGO interferometers in
quantum-state preparation
- …