44 research outputs found

    Spatial characterisation of the internal gas target at the ESR for the FOCAL experiment

    Get PDF

    Approaching the Gamow Window with Stored Ions : Direct Measurement of Xe 124 (p,Îł) in the ESR Storage Ring

    Get PDF
    © 2019 American Physical Society. All rights reserved.We report the first measurement of low-energy proton-capture cross sections of Xe124 in a heavy-ion storage ring. Xe12454+ ions of five different beam energies between 5.5 and 8 AMeV were stored to collide with a windowless hydrogen target. The Cs125 reaction products were directly detected. The interaction energies are located on the high energy tail of the Gamow window for hot, explosive scenarios such as supernovae and x-ray binaries. The results serve as an important test of predicted astrophysical reaction rates in this mass range. Good agreement in the prediction of the astrophysically important proton width at low energy is found, with only a 30% difference between measurement and theory. Larger deviations are found above the neutron emission threshold, where also neutron and γ widths significantly impact the cross sections. The newly established experimental method is a very powerful tool to investigate nuclear reactions on rare ion beams at low center-of-mass energies.Peer reviewedFinal Published versio

    Consensus based framework for digital mobility monitoring

    Get PDF
    Digital mobility assessment using wearable sensor systems has the potential to capture walking performance in a patient’s natural environment. It enables monitoring of health status and disease progression and evaluation of interventions in real-world situations. In contrast to laboratory settings, real-world walking occurs in non-conventional environments and under unconstrained and uncontrolled conditions. Despite the general understanding, there is a lack of agreed definitions about what constitutes real-world walking, impeding the comparison and interpretation of the acquired data across systems and studies. The goal of this study was to obtain expert-based consensus on specific aspects of real-world walking and to provide respective definitions in a common terminological framework. An adapted Delphi method was used to obtain agreed definitions related to real-world walking. In an online survey, 162 participants from a panel of academic, clinical and industrial experts with experience in the field of gait analysis were asked for agreement on previously specified definitions. Descriptive statistics was used to evaluate whether consent (> 75% agreement as defined a priori) was reached. Of 162 experts invited to participate, 51 completed all rounds (31.5% response rate). We obtained consensus on all definitions (“Walking” > 90%, “Purposeful” > 75%, “Real-world” > 90%, “Walking bout” > 80%, “Walking speed” > 75%, “Turning” > 90% agreement) after two rounds. The identification of a consented set of real-world walking definitions has important implications for the development of assessment and analysis protocols, as well as for the reporting and comparison of digital mobility outcomes across studies and systems. The definitions will serve as a common framework for implementing digital and mobile technologies for gait assessment and are an important link for the transition from supervised to unsupervised gait assessment

    Cardiac rehabilitation in Austria: long term health-related quality of life outcomes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The goal of cardiac rehabilitation programs is not only to prolong life but also to improve physical functioning, symptoms, well-being, and health-related quality of life (HRQL). The aim of this study was to document the long-term effect of a 1-month inpatient cardiac rehabilitation intervention on HRQL in Austria.</p> <p>Methods</p> <p>Patients (N = 487, 64.7% male, age 60.9 ± 12.5 SD years) after myocardial infarction, with or without percutaneous interventions, coronary artery bypass grafting or valve surgery underwent inpatient cardiac rehabilitation and were included in this long-term observational study (two years follow-up). HRQL was measured with both the MacNew Heart Disease Quality of Life Instrument [MacNew] and EuroQoL-5D [EQ-5D].</p> <p>Results</p> <p>All MacNew scale scores improved significantly (p < 0.001) and exceeded the minimal important difference (0.5 MacNew points) by the end of rehabilitation. Although all MacNew scale scores deteriorated significantly over the two year follow-up period (p < .001), all MacNew scale scores still remained significantly higher than the pre-rehabilitation values. The mean improvement after two years in the MacNew social scale exceeded the minimal important difference while MacNew scale scores greater than the minimal important difference were reported by 40-49% of the patients.</p> <p>Two years after rehabilitation the mean improvement in the EQ-5D Visual Analogue Scale score was not significant with no significant change in the proportion of patients reporting problems at this time.</p> <p>Conclusion</p> <p>These findings provide a first indication that two years following inpatient cardiac rehabilitation in Austria, the long-term improvements in HRQL are statistically significant and clinically relevant for almost 50% of the patients. Future controlled randomized trials comparing different cardiac rehabilitation programs are needed.</p

    Walking on common ground: a cross-disciplinary scoping review on the clinical utility of digital mobility outcomes

    Get PDF
    Physical mobility is essential to health, and patients often rate it as a high-priority clinical outcome. Digital mobility outcomes (DMOs), such as real-world gait speed or step count, show promise as clinical measures in many medical conditions. However, current research is nascent and fragmented by discipline. This scoping review maps existing evidence on the clinical utility of DMOs, identifying commonalities across traditional disciplinary divides. In November 2019, 11 databases were searched for records investigating the validity and responsiveness of 34 DMOs in four diverse medical conditions (Parkinson’s disease, multiple sclerosis, chronic obstructive pulmonary disease, hip fracture). Searches yielded 19,672 unique records. After screening, 855 records representing 775 studies were included and charted in systematic maps. Studies frequently investigated gait speed (70.4% of studies), step length (30.7%), cadence (21.4%), and daily step count (20.7%). They studied differences between healthy and pathological gait (36.4%), associations between DMOs and clinical measures (48.8%) or outcomes (4.3%), and responsiveness to interventions (26.8%). Gait speed, step length, cadence, step time and step count exhibited consistent evidence of validity and responsiveness in multiple conditions, although the evidence was inconsistent or lacking for other DMOs. If DMOs are to be adopted as mainstream tools, further work is needed to establish their predictive validity, responsiveness, and ecological validity. Cross-disciplinary efforts to align methodology and validate DMOs may facilitate their adoption into clinical practice

    Connecting real-world digital mobility assessment to clinical outcomes for regulatory and clinical endorsement–the Mobilise-D study protocol

    Get PDF
    Background The development of optimal strategies to treat impaired mobility related to ageing and chronic disease requires better ways to detect and measure it. Digital health technology, including body worn sensors, has the potential to directly and accurately capture real-world mobility. Mobilise-D consists of 34 partners from 13 countries who are working together to jointly develop and implement a digital mobility assessment solution to demonstrate that real-world digital mobility outcomes have the potential to provide a better, safer, and quicker way to assess, monitor, and predict the efficacy of new interventions on impaired mobility. The overarching objective of the study is to establish the clinical validity of digital outcomes in patient populations impacted by mobility challenges, and to support engagement with regulatory and health technology agencies towards acceptance of digital mobility assessment in regulatory and health technology assessment decisions. Methods/design The Mobilise-D clinical validation study is a longitudinal observational cohort study that will recruit 2400 participants from four clinical cohorts. The populations of the Innovative Medicine Initiative-Joint Undertaking represent neurodegenerative conditions (Parkinson’s Disease), respiratory disease (Chronic Obstructive Pulmonary Disease), neuro-inflammatory disorder (Multiple Sclerosis), fall-related injuries, osteoporosis, sarcopenia, and frailty (Proximal Femoral Fracture). In total, 17 clinical sites in ten countries will recruit participants who will be evaluated every six months over a period of two years. A wide range of core and cohort specific outcome measures will be collected, spanning patient-reported, observer-reported, and clinician-reported outcomes as well as performance-based outcomes (physical measures and cognitive/mental measures). Daily-living mobility and physical capacity will be assessed directly using a wearable device. These four clinical cohorts were chosen to obtain generalizable clinical findings, including diverse clinical, cultural, geographical, and age representation. The disease cohorts include a broad and heterogeneous range of subject characteristics with varying chronic care needs, and represent different trajectories of mobility disability. Discussion The results of Mobilise-D will provide longitudinal data on the use of digital mobility outcomes to identify, stratify, and monitor disability. This will support the development of widespread, cost-effective access to optimal clinical mobility management through personalised healthcare. Further, Mobilise-D will provide evidence-based, direct measures which can be endorsed by regulatory agencies and health technology assessment bodies to quantify the impact of disease-modifying interventions on mobility

    BASIC oder ADVANCED? Extracurriculare Notfallsimulation von Studierenden fĂŒr Studierende

    No full text

    Objective sensor-based gait measures reflect motor impairment in multiple sclerosis patients: Reliability and clinical validation of a wearable sensor device

    No full text
    Background Gait deficits are common in multiple sclerosis (MS) and contribute to disability but may not be easily detected in the early stages of the disease. Objectives We investigated whether sensor-based gait analysis is able to detect gait impairments in patients with MS (PwMS). Methods A foot-worn sensor-based gait analysis system was used in 102 PwMS and 22 healthy controls (HC) that were asked to perform the 25-foot walking test (25FWT) two times in a self-selected speed (25FWT pref), followed by two times in a speed as fast as possible (25FWT fast). The Multiple Sclerosis Walking Scale (MSWS-12) was used as a subjective measure of patient mobility. Patients were divided into EDSS and functional system subgroups. Results Datasets between two consecutive measurements (test-retest-reliability) were highly correlated in all analysed mean gait parameters (e.g. 25FWT fast: stride length r = 0.955, gait speed r = 0.969) Subgroup analysis between HC and PwMS with lower (EDSS≀3.5) and higher (EDSS 4.0–7.0) disability showed significant differences in mean stride length, gait speed, toe off angle, stance time and swing time (e.g. stride length of EDSS subgroups 25FWT fast p ≀ 0.001, 25FWT pref p = 0.003). The differences between EDSS subgroups were more pronounced in fast than in self-selected gait speed (e.g. stride length 25FWT fast 33.6 cm vs. 25FWT pref 16.3 cm). Stride length (25FWT fast) highly correlated to EDSS (r=-0.583) and MSWS-12 (r=-0.668). We observed significant differences between HC and PwMS with (FS 0–1) and without (FS≄2) pyramidal or cerebellar disability (e.g. gait speed of FS subgroups p ≀ 0.001). Conclusion Sensor-based gait analysis objectively supports the clinical assessment of gait abnormalities even in the lower stages of MS, especially when walking with fast speed. Stride length and gait speed where identified as the most clinically relevant gait measures. Thus, it may be used to support the assessment of PwMS with gait impairment in the future, e.g. for more objective classification of disability. Its role in home-monitoring scenarios need to be evaluated in further studies
    corecore