1,078 research outputs found

    Kinin B(1) receptor deficiency leads to leptin hypersensitivity and resistance to obesity

    Get PDF
    OBJECTIVE-Kinins mediate pathophysiological processes related to hypertension, pain, and inflammation through the activation of two G-protein-coupled receptors, named B(1) and B(2). Although these peptides have been related to glucose homeostasis, their effects on energy balance are still unknown.RESEARCH DESIGN and METHODS-Using genetic and pharmacological strategies to abrogate the kinin B(1) receptor in different animal models of obesity, here we present evidence of a novel role for kinins in the regulation of satiety and adiposity.RESULTS-Kinin B(1) receptor deficiency in mice (B(1)(-/-)) resulted in less fat content, hypoleptinemia, increased leptin sensitivity, and robust protection against high-fat diet-induced weight gain. Under high-fat diet, B(1)(-/-) also exhibited reduced food intake, improved lipid oxidation, and increased energy expenditure. Surprisingly, B(1) receptor deficiency was not able to decrease food intake and adiposity in obese mice lacking leptin (ob/ob-B(1)(-/-)). However, ob/ob-B(1)(-/-) mice were more responsive to the effects of exogenous leptin on body weight and food intake, suggesting that B(1) receptors may be dependent on leptin to display their metabolic roles. Finally, inhibition of weight gain and food intake by B(1) receptor ablation was pharmacologically confirmed by long-term administration of the kinin B(1) receptor antagonist SSR240612 to mice under high-fat diet.CONCLUSIONS-Our data suggest that kinin B(1) receptors participate in the regulation of the energy balance via a mechanism that could involve the modulation of leptin sensitivity.Universidade Federal de São Paulo, Dept Biophys, BR-04023062 São Paulo, BrazilUniv Mogi das Cruzes, Mogi Das Cruzes, BrazilUniversidade Federal de São Paulo, Dept Physiol, BR-04023062 São Paulo, BrazilSanofi Aventis, Montpellier, FranceUniversidade Federal de São Paulo, Dept Med, BR-04023062 São Paulo, BrazilInst Natl Sante & Rech Med, Dept Renal & Cardiac Remodeling, U858 I2MR, Toulouse, FranceUniv Toulouse 3, Inst Med Mol Rangueil, F-31062 Toulouse, FranceInst Natl Rech Agron AgroParisTech, UMR914 Nutr Physiol & Ingest Behav, Paris, FranceMax Delbruck Ctr Mol Med, Berlin, GermanyUniversidade Federal de São Paulo, Dept Biophys, BR-04023062 São Paulo, BrazilUniversidade Federal de São Paulo, Dept Physiol, BR-04023062 São Paulo, BrazilUniversidade Federal de São Paulo, Dept Med, BR-04023062 São Paulo, BrazilWeb of Scienc

    After DART: Using the First Full-scale Test of a Kinetic Impactor to Inform a Future Planetary Defense Mission

    Get PDF
    NASA’s Double Asteroid Redirection Test (DART) is the first full-scale test of an asteroid deflection technology. Results from the hypervelocity kinetic impact and Earth-based observations, coupled with LICIACube and the later Hera mission, will result in measurement of the momentum transfer efficiency accurate to ∼10% and characterization of the Didymos binary system. But DART is a single experiment; how could these results be used in a future planetary defense necessity involving a different asteroid? We examine what aspects of Dimorphos’s response to kinetic impact will be constrained by DART results; how these constraints will help refine knowledge of the physical properties of asteroidal materials and predictive power of impact simulations; what information about a potential Earth impactor could be acquired before a deflection effort; and how design of a deflection mission should be informed by this understanding. We generalize the momentum enhancement factor β, showing that a particular direction-specific β will be directly determined by the DART results, and that a related direction-specific β is a figure of merit for a kinetic impact mission. The DART β determination constrains the ejecta momentum vector, which, with hydrodynamic simulations, constrains the physical properties of Dimorphos’s near-surface. In a hypothetical planetary defense exigency, extrapolating these constraints to a newly discovered asteroid will require Earth-based observations and benefit from in situ reconnaissance. We show representative predictions for momentum transfer based on different levels of reconnaissance and discuss strategic targeting to optimize the deflection and reduce the risk of a counterproductive deflection in the wrong direction

    Micro-Raman and micro-transmission imaging of epitaxial graphene grown on the Si and C faces of 6H-SiC

    Get PDF
    Micro-Raman and micro-transmission imaging experiments have been done on epitaxial graphene grown on the C- and Si-faces of on-axis 6H-SiC substrates. On the C-face it is shown that the SiC sublimation process results in the growth of long and isolated graphene ribbons (up to 600 μm) that are strain-relaxed and lightly p-type doped. In this case, combining the results of micro-Raman spectroscopy with micro-transmission measurements, we were able to ascertain that uniform monolayer ribbons were grown and found also Bernal stacked and misoriented bilayer ribbons. On the Si-face, the situation is completely different. A full graphene coverage of the SiC surface is achieved but anisotropic growth still occurs, because of the step-bunched SiC surface reconstruction. While in the middle of reconstructed terraces thin graphene stacks (up to 5 layers) are grown, thicker graphene stripes appear at step edges. In both the cases, the strong interaction between the graphene layers and the underlying SiC substrate induces a high compressive thermal strain and n-type doping

    Learning Curves of Minimally Invasive Distal Pancreatectomy in Experienced Pancreatic Centers

    Get PDF
    IMPORTANCE Understanding the learning curve of a new complex surgical technique helps to reduce potential patient harm. Current series on the learning curve of minimally invasive distal pancreatectomy (MIDP) are mostly small, single-center series, thus providing limited data.OBJECTIVE To evaluate the length of pooled learning curves of MIDP in experienced centers.DESIGN, SETTING, AND PARTICIPANTS This international, multicenter, retrospective cohort study included MIDP procedures performed from January 1, 2006, through June 30, 2019, in 26 European centers from 8 countries that each performed more than 15 distal pancreatectomies annually, with an overall experience exceeding 50 MIDP procedures. Consecutive patients who underwent elective laparoscopic or robotic distal pancreatectomy for all indications were included. Data were analyzed between September 1, 2021, and May 1, 2022.EXPOSURES The learning curve for MIDP was estimated by pooling data from all centers.MAIN OUTCOMES AND MEASURES The learning curvewas assessed for the primary textbook outcome (TBO), which is a composite measure that reflects optimal outcome, and for surgical mastery. Generalized additive models and a 2-piece linear model with a break point were used to estimate the learning curve length of MIDP. Case mix-expected probabilities were plotted and compared with observed outcomes to assess the association of changing case mix with outcomes. The learning curve also was assessed for the secondary outcomes of operation time, intraoperative blood loss, conversion to open rate, and postoperative pancreatic fistula grade B/C.RESULTS From a total of 2610 MIDP procedures, the learning curve analysis was conducted on 2041 procedures (mean [SD] patient age, 58 [15.3] years; among 2040 with reported sex, 1249 were female [61.2%] and 791 male [38.8%]). The 2-piece model showed an increase and eventually a break point for TBO at 85 procedures (95% CI, 13-157 procedures), with a plateau TBO rate at 70%. The learning-associated loss of TBO rate was estimated at 3.3%. For conversion, a break point was estimated at 40 procedures (95% CI, 11-68 procedures); for operation time, at 56 procedures (95% CI, 35-77 procedures); and for intraoperative blood loss, at 71 procedures (95% CI, 28-114 procedures). For postoperative pancreatic fistula, no break point could be estimated.CONCLUSION AND RELEVANCE In experienced international centers, the learning curve length of MIDP for TBO was considerable with 85 procedures. These findings suggest that although learning curves for conversion, operation time, and intraoperative blood loss are completed earlier, extensive experience may be needed to master the learning curve of MIDP

    PTX3 Polymorphisms and Invasive Mold Infections After Solid Organ Transplant

    Get PDF
    Donor PTX3 polymorphisms were shown to influence the risk of invasive aspergillosis among hematopoietic stem cell transplant recipients. Here, we show that PTX3 polymorphisms are independent risk factors for invasive mold infections among 1101 solid organ transplant recipients, thereby strengthening their role in mold infection pathogenesis and patients' risk stratificatio

    Reply to Cunha et al

    Get PDF

    Ejecta Evolution Following a Planned Impact into an Asteroid: The First Five Weeks

    Full text link
    The impact of the DART spacecraft into Dimorphos, moon of the asteroid Didymos, changed Dimorphos' orbit substantially, largely from the ejection of material. We present results from twelve Earth-based facilities involved in a world-wide campaign to monitor the brightness and morphology of the ejecta in the first 35 days after impact. After an initial brightening of ~1.4 magnitudes, we find consistent dimming rates of 0.11-0.12 magnitudes/day in the first week, and 0.08-0.09 magnitudes/day over the entire study period. The system returned to its pre-impact brightness 24.3-25.3 days after impact through the primary ejecta tail remained. The dimming paused briefly eight days after impact, near in time to the appearance of the second tail. This was likely due to a secondary release of material after re-impact of a boulder released in the initial impact, through movement of the primary ejecta through the aperture likely played a role.Comment: 16 pages, 5 Figures, accepted in the Astrophysical Journal Letters (ApJL) on October 16, 202

    Mitochondrial mosaics in the liver of 3 infants with mtDNA defects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In muscle cytochrome oxidase (COX) negative fibers (mitochondrial mosaics) have often been visualized.</p> <p>Methods</p> <p>COX activity staining of liver for light and electron microscopy, muscle stains, blue native gel electrophoresis and activity assays of respiratory chain proteins, their immunolocalisation, mitochondrial and nuclear DNA analysis.</p> <p>Results</p> <p>Three unrelated infants showed a mitochondrial mosaic in the liver after staining for COX activity, i.e. hepatocytes with strongly reactive mitochondria were found adjacent to cells with many negative, or barely reactive, mitochondria. Deficiency was most severe in the patient diagnosed with Pearson syndrome. Ragged-red fibers were absent in muscle biopsies of all patients. Enzyme biochemistry was not diagnostic in muscle, fibroblasts and lymphocytes. Blue native gel electrophoresis of liver tissue, but not of muscle, demonstrated a decreased activity of complex IV; in both muscle and liver subcomplexes of complex V were seen. Immunocytochemistry of complex IV confirmed the mosaic pattern in two livers, but not in fibroblasts. MRI of the brain revealed severe white matter cavitation in the Pearson case, but only slight cortical atrophy in the Alpers-Huttenlocher patient, and a normal image in the 3rd. MtDNA in leucocytes showed a common deletion in 50% of the mtDNA molecules of the Pearson patient. In the patient diagnosed with Alpers-Huttenlocher syndrome, mtDNA was depleted for 60% in muscle. In the 3rd patient muscular and hepatic mtDNA was depleted for more than 70%. Mutations in the nuclear encoded gene of <it>POLG </it>were subsequently found in both the 2nd and 3rd patients.</p> <p>Conclusion</p> <p>Histoenzymatic COX staining of a liver biopsy is fast and yields crucial data about the pathogenesis; it indicates whether mtDNA should be assayed. Each time a mitochondrial disorder is suspected and muscle data are non-diagnostic, a liver biopsy should be recommended. Mosaics are probably more frequent than observed until now. A novel pathogenic mutation in <it>POLG </it>is reported.</p> <p>Tentative explanations for the mitochondrial mosaics are, in one patient, unequal partition of mutated mitochondria during mitoses, and in two others, an interaction between products of several genes required for mtDNA maintenance.</p

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Full text link
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).Comment: 48 pages, 29 figures, Accepted for publication in Experimental Astronomy with minor editin

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory. Athena is a versatile observatory designed to address the Hot and Energetic Universe science theme, as selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), X-IFU aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over a hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR (i.e. in the course of its preliminary definition phase, so-called B1), browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters, such as the instrument efficiency, spectral resolution, energy scale knowledge, count rate capability, non X-ray background and target of opportunity efficiency. Finally, we briefly discuss the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, touch on communication and outreach activities, the consortium organisation and the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. The X-IFU will be provided by an international consortium led by France, The Netherlands and Italy, with ESA member state contributions from Belgium, Czech Republic, Finland, Germany, Poland, Spain, Switzerland, with additional contributions from the United States and Japan.The French contribution to X-IFU is funded by CNES, CNRS and CEA. This work has been also supported by ASI (Italian Space Agency) through the Contract 2019-27-HH.0, and by the ESA (European Space Agency) Core Technology Program (CTP) Contract No. 4000114932/15/NL/BW and the AREMBES - ESA CTP No.4000116655/16/NL/BW. This publication is part of grant RTI2018-096686-B-C21 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe”. This publication is part of grant RTI2018-096686-B-C21 and PID2020-115325GB-C31 funded by MCIN/AEI/10.13039/501100011033
    corecore