190 research outputs found

    Defocus test and defocus correction in full-field optical coherence tomography

    Full text link
    We report experimental evidence and correction of defocus in full-field OCT of biological samples due to mismatch of the refractive index of biological tissues and water. Via a metric based on the image quality, we demonstrate that we are able to compensate this index-induced defocus and to recover a sharp image in depth.Comment: 7 pages, 3 figures, minor changes, 1 figure adde

    Polarization-sensitive quantum-optical coherence tomography

    Full text link
    We set forth a polarization-sensitive quantum-optical coherence tomography (PS-QOCT) technique that provides axial optical sectioning with polarization-sensitive capabilities. The technique provides a means for determining information about the optical path length between isotropic reflecting surfaces, the relative magnitude of the reflectance from each interface, the birefringence of the interstitial material, and the orientation of the optical axis of the sample. PS-QOCT is immune to sample dispersion and therefore permits measurements to be made at depths greater than those accessible via ordinary optical coherence tomography. We also provide a general Jones matrix theory for analyzing PS-QOCT systems and outline an experimental procedure for carrying out such measurements.Comment: 15 pages, 5 figures, to appear in Physical Review

    High-precision, high-accuracy ultralong-range swept-source optical coherence tomography using vertical cavity surface emitting laser light source

    Get PDF
    We demonstrate ultralong-range swept-source optical coherence tomography (OCT) imaging using vertical cavity surface emitting laser technology. The ability to adjust laser parameters and high-speed acquisition enables imaging ranges from a few centimeters up to meters using the same instrument. We discuss the challenges of long-range OCT imaging. In vivo human-eye imaging and optical component characterization are presented. The precision and accuracy of OCT-based measurements are assessed and are important for ocular biometry and reproducible intraocular distance measurement before cataract surgery. Additionally, meter-range measurement of fiber length and multicentimeter-range imaging are reported. 3D visualization supports a class of industrial imaging applications of OCT.National Institutes of Health (U.S.) (R01-EY011289-26)National Institutes of Health (U.S.) (R01 EY013178-12)National Institutes of Health (U.S.) (R01-EY013516-09)National Institutes of Health (U.S.) (R01-EY019029-03)National Institutes of Health (U.S.) (R01-CA075289-15)National Institutes of Health (U.S.) (R01-NS057476-05)National Institutes of Health (U.S.) (R44-CA101067-05)United States. Air Force Office of Scientific Research (FA9550-10-1-0551)United States. Air Force Office of Scientific Research (FA9550-10-1-0063

    Depth-resolved microscopy of cortical hemodynamics with optical coherence tomography

    Get PDF
    We describe depth-resolved microscopy of cortical hemodynamics with high-speed spectral/Fourier domain optical coherence tomography (OCT). Stimulus-evoked changes in blood vessel diameter, flow, and total hemoglobin were measured in the rat somatosensory cortex. The results show OCT measurements of hemodynamic changes during functional activation and represent an important step toward understanding functional hyperemia at the microscopic level.National Institutes of Health (U.S.) (R01-NS057476)National Institutes of Health (U.S.) (P01NS055104)National Institutes of Health (U.S.) (P50NS010828)National Institutes of Health (U.S.) (K99NS067050)National Institutes of Health (U.S.) (R01-CA075289-12)United States. Air Force Office of Scientific Research (FA9550-07-1-0014)United States. Dept. of Defense. Medical Free Electron Laser Program (FA9550-07-1-0101

    Frequency comb swept lasers

    Get PDF
    We demonstrate a frequency comb (FC) swept laser and a frequency comb Fourier domain mode locked (FC-FDML) laser for applications in optical coherence tomography (OCT). The fiber-based FC swept lasers operate at a sweep rate of 1kHz and 120kHz, respectively over a 135nm tuning range centered at 1310nm with average output powers of 50mW. A 25GHz free spectral range frequency comb filter in the swept lasers causes the lasers to generate a series of well defined frequency steps. The narrow bandwidth (0.015nm) of the frequency comb filter enables a ~-1.2dB sensitivity roll off over ~3mm range, compared to conventional swept source and FDML lasers which have −10dB and −5dB roll offs, respectively. Measurements at very long ranges are possible with minimal sensitivity loss, however reflections from outside the principal measurement range of 0-3mm appear aliased back into the principal range. In addition, the frequency comb output from the lasers are equally spaced in frequency (linear in k-space). The filtered laser output can be used to self-clock the OCT interference signal sampling, enabling direct fast Fourier transformation of the fringe signals, without the need for fringe recalibration procedures. The design and operation principles of FC swept lasers are discussed and designs for short cavity lasers for OCT and interferometric measurement applications are proposed.National Institutes of Health (U.S.) (R01-CA75289-12)National Institutes of Health (U.S.) (R01-EY011289-24)United States. Air Force Office of Scientific Research (FA9550-07-1-0014)United States. Dept. of Defense. Medical Free Electron Laser Program (FA9550-07-1-0101)National Science council of Taiwan. Taiwan Merit ScholarshipCenter for Integration of Medicine and Innovative Technolog

    Quantitative cerebral blood flow with optical coherence tomography

    Get PDF
    Absolute measurements of cerebral blood flow (CBF) are an important endpoint in studies of cerebral pathophysiology. Currently no accepted method exists for in vivo longitudinal monitoring of CBF with high resolution in rats and mice. Using three-dimensional Doppler Optical Coherence Tomography and cranial window preparations, we present methods and algorithms for regional CBF measurements in the rat cortex. Towards this end, we develop and validate a quantitative statistical model to describe the effect of static tissue on velocity sensitivity. This model is used to design scanning protocols and algorithms for sensitive 3D flow measurements and angiography of the cortex. We also introduce a method of absolute flow calculation that does not require explicit knowledge of vessel angles. We show that OCT estimates of absolute CBF values in rats agree with prior measures by autoradiography, suggesting that Doppler OCT can perform absolute flow measurements in animal models.National Institutes of Health (U.S.) (Grant number R01-NS057476)National Institutes of Health (U.S.) (Grant number P01NS055104)National Institutes of Health (U.S.) (Grant number P50NS010828)ational Institutes of Health (U.S.) (Grant number K99NS067050)National Institutes of Health (U.S.) (Grant number R01-CA075289-13)United States. Air Force Office of Scientific Research (FA9550-07-1-0014)United States. Dept. of Defense. Medical Free Electron Laser Program (FA9550-07-1-0101

    Split-spectrum amplitude-decorrelation angiography with optical coherence tomography

    Get PDF
    Amplitude decorrelation measurement is sensitive to transverse flow and immune to phase noise in comparison to Doppler and other phase-based approaches. However, the high axial resolution of OCT makes it very sensitive to the pulsatile bulk motion noise in the axial direction. To overcome this limitation, we developed split-spectrum amplitude-decorrelation angiography (SSADA) to improve the signal-to-noise ratio (SNR) of flow detection. The full OCT spectrum was split into several narrower bands. Inter-B-scan decorrelation was computed using the spectral bands separately and then averaged. The SSADA algorithm was tested on in vivo images of the human macula and optic nerve head. It significantly improved both SNR for flow detection and connectivity of microvascular network when compared to other amplitude-decorrelation algorithms.National Institutes of Health (U.S.) (Grant R01 EY013516)National Institutes of Health (U.S.) (Grant R01-EY11289-26)United States. Air Force Office of Scientific Research (FA9550-10-1-0551

    Review of laser speckle contrast techniques for visualizing tissue perfusion

    Get PDF
    When a diffuse object is illuminated with coherent laser light, the backscattered light will form an interference pattern on the detector. This pattern of bright and dark areas is called a speckle pattern. When there is movement in the object, the speckle pattern will change over time. Laser speckle contrast techniques use this change in speckle pattern to visualize tissue perfusion. We present and review the contribution of laser speckle contrast techniques to the field of perfusion visualization and discuss the development of the techniques
    corecore