112 research outputs found

    NEMO: A Project for a km3^3 Underwater Detector for Astrophysical Neutrinos in the Mediterranean Sea

    Full text link
    The status of the project is described: the activity on long term characterization of water optical and oceanographic parameters at the Capo Passero site candidate for the Mediterranean km3^3 neutrino telescope; the feasibility study; the physics performances and underwater technology for the km3^3; the activity on NEMO Phase 1, a technological demonstrator that has been deployed at 2000 m depth 25 km offshore Catania; the realization of an underwater infrastructure at 3500 m depth at the candidate site (NEMO Phase 2).Comment: Proceeding of ISCRA 2006, Erice 20-27 June 200

    Measurement of the atmospheric muon flux with the NEMO Phase-1 detector

    Get PDF
    The NEMO Collaboration installed and operated an underwater detector including prototypes of the critical elements of a possible underwater km3 neutrino telescope: a four-floor tower (called Mini-Tower) and a Junction Box. The detector was developed to test some of the main systems of the km3 detector, including the data transmission, the power distribution, the timing calibration and the acoustic positioning systems as well as to verify the capabilities of a single tridimensional detection structure to reconstruct muon tracks. We present results of the analysis of the data collected with the NEMO Mini-Tower. The position of photomultiplier tubes (PMTs) is determined through the acoustic position system. Signals detected with PMTs are used to reconstruct the tracks of atmospheric muons. The angular distribution of atmospheric muons was measured and results compared with Monte Carlo simulations.Comment: Astrop. Phys., accepte

    The ANTARES Optical Beacon System

    Get PDF
    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.

    Performance of the First ANTARES Detector Line

    Get PDF
    In this paper we report on the data recorded with the first Antares detector line. The line was deployed on the 14th of February 2006 and was connected to the readout two weeks later. Environmental data for one and a half years of running are shown. Measurements of atmospheric muons from data taken from selected runs during the first six months of operation are presented. Performance figures in terms of time residuals and angular resolution are given. Finally the angular distribution of atmospheric muons is presented and from this the depth profile of the muon intensity is derived.Comment: 14 pages, 9 figure

    First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope

    Get PDF
    In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved

    Use of electronic devices by people attending vision rehabilitation services in Italy: A study based on the device and aids registry (D.A.Re)

    Get PDF
    Purpose To investigate the characteristics of electronic device users, specifically smartphones and tablets, in the Device & Aids Register (D.A.Re), from several low-vision rehabilitation services in Italy. Methods We collected general and clinical information about ocular and systemic diseases, visual function, reading speed and Instrumental Activities of Daily Living (IADL) questionnaire score. Technological details of each optical and electronic device, (including screen size, touch-screen and OCR functions, text-to-speech function) were also collected. Results 1218 patients (752 females and 466 males) were included in our analysis, mean age 71.5 (±18.8) years. Users of electronic aids (n.237) were slightly younger (67 vs 72 years, p < 0.001) than non-users (n.981), had a worse reading speed (38 vs 65 words/minute), critical print size (43 vs 28 print size, p < 0.001), poorer visual acuity (VA)(1.0 logMAR or less: 30% non-users vs 73% users, p < 0.001) and more commonly visual field restriction within 10° (23% vs 14%, p = 0.001). A similar proportion of users and non-users were retired (about 70%) and about 16–17% were employed. The use of portable electronic devices (5″or less, p < 0.001; 6″ to 18″ screen size, p = 0.017) was associated with better IADL scores, and the use of stand devices with worse IADL score (p < 0.001); Furthermore, using smartphones and tablets (193 subjects) was strongly associated with better IADL scores. Conclusion We found that using electronic devices, and especially smartphone and tablets, were associated with better vision-related quality of life in low-vision people attending rehabilitation services. While this association does not mean causality, these findings seemed robust to confounder adjustment

    Healthcare practitioners and robotic-assisted rehabilitation: understanding needs and barriers

    Get PDF
    Backgrounds: In recent years, numerous robotic devices, together with allied technologies, have been developed to support rehabilitation, both in research settings and industry. Although robotic-assisted rehabilitation and related technologies hold significant promise for supporting healthcare practitioners and enhancing patient care, their use in clinical practice remains limited. One of the motivations could be that final users’ needs have not been given due consideration so far. As a matter of fact, understanding user needs and perceptions is crucial for designing these technological devices and for creating new organizational models within hospitals aiming to establish and maintain robotics-assisted rehabilitation gyms. Methods: We developed and distributed an online survey to the Italian community of healthcare practitioners working in rehabilitation, to depict the current landscape of robotic-assisted rehabilitation and to understand their opinions and demands across various domains and diseases. The questionnaire is divided into two main parts. The first section pertains to the respondents' demographics and professional experience. The second part includes questions about eight different categories of rehabilitative devices. For each category, practitioners can indicate whether they use a device in their practice, their perceptions, and any perceived barriers. Additionally, they can fill out a System Usability Scale for a specific device in that category. Results: We collected answers from 423 Italian rehabilitation professionals, including various clinical roles, that revealed significant insights into the use of robotics in rehabilitation. Gender distribution shows a high prevalence of female professionals. 40% of respondents reported being unfamiliar with any robotics devices. Advanced treadmills are the most known and used robots. Generally, usage and experience with devices are associated with positive attitudes towards robotics-assisted rehabilitation. Lack of financial resources and scientific evidence, as well as lack of opportunities and training, are the most reported barriers. Conclusions: Despite a general positivity towards technology, there is a substantial lack of awareness about rehabilitation devices among professionals. The survey highlights the need for enhanced training and education on robotics in rehabilitation programs. Additionally, the limited focus on home rehabilitation is noted. The study emphasizes the importance of verifying both the effectiveness and economic sustainability of robotic devices in clinical practice

    Status of NEMO

    Get PDF
    The activities towards the realization of a km3 Cherenkov neutrino detector carried out by the NEMO Collaboration are described. Long-term exploration of a 3500 m deep-sea site close to the Sicilian coast has shown that it is optimal for the installation of the detector. The realization of a Phase-1 project, which is under way, will validate the proposed technologies for the realization of the km3 detector on a Test Site at 2000 m depth. The realization of a new infrastructure on the candidate site (Phase-2 project) will provide the possibility to test detector components at 3500 m depth
    corecore