1,464 research outputs found

    Effectiveness and safety of obeticholic acid in a Southern European multicenter cohort of patients with primary biliary cholangitis and suboptimal response to ursodeoxycholic acid

    Get PDF
    Background Obeticholic acid (OCA) was recently approved as the only on-label alternative for patients with primary biliary cholangitis (PBC) with intolerance or suboptimal response to ursodeoxycholic acid (UDCA). However, few data are available outside clinical trials. Aim To assess the effectiveness and safety of OCA in a real-world cohort of patients with non-effective UDCA therapy. Methods Open-label, prospective, real-world, multicentre study, enrolling consecutive patients who did not meet Paris II criteria, from 18 institutions in Spain and Portugal. Effectiveness was assessed by the changes in GLOBE and UK-PBC scores from baseline. POISE and Paris II criteria were evaluated after 12 months of OCA . Liver fibrosis was evaluated by FIB-4 and AST to platelet ratio index (APRI). Results One hundred and twenty patients were eligible, median time since PBC diagnosis 9.3 (4.0-13.8) years, 21.7% had cirrhosis, and 26.7% received had previous or concomitant treatment with fibrates. Seventy-eight patients completed at least 1 year of OCA. The Globe-PBC score decreased to 0.17 (95% CI 0.05 to 0.28; P = 0.005) and the UK-PBC score decreased to 0.81 (95% CI -0.19 to 1.80; P = 0.11). There was a significant decrease in alkaline phosphatase of 81.3 U/L (95% CI 42.5 to 120; P < 0.001), ALT 22.1 U/L (95% CI 10.4 to 33.8; P < 0.001) and bilirubin 0.12 mg/dL (95% CI 0 to 0.24; P = 0.044). FIB-4 and APRI remained stable. According to the POISE criteria, 29.5% (23 out of 78) achieved response. The adverse events rate was 35%; 11.67% discontinued (8.3% due to pruritus). Conclusions This study supports data from phase III trials with significant improvement of PBC-Globe continuous prognostic marker score among OCA-treated patients with good tolerability

    Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure

    Get PDF
    Altres ajuts: FundaciĂłn Interhospitalaria para la InvestigaciĂłn Cardiovascular (FIC Foundation); Abbott.Objective: Left atrial appendage (LAA) thrombus has heretofore been considered a contraindication to percutaneous LAA closure (LAAC). Data regarding its management are very limited. The aim of this study was to analyse the medical and invasive treatment of patients referred for LAAC in the presence of LAA thrombus. Methods: This multicentre observational registry included 126 consecutive patients referred for LAAC with LAA thrombus on preprocedural imaging. Treatment strategies included intensification of antithrombotic therapy (IAT) or direct LAAC. The primary and secondary endpoints were a composite of bleeding, stroke and death at 18 months, and procedural success, respectively. Results: IAT was the preferred strategy in 57.9% of patients, with total thrombus resolution observed in 60.3% and 75.3% after initial and subsequent IAT, respectively. Bleeding complications and stroke during IAT occurred in 9.6% and 2.9%, respectively, compared with 3.8% bleeding and no embolic events in the direct LAAC group before the procedure. Procedural success was 90.5% (96.2% vs 86.3% in direct LAAC and IAT group, respectively, p=0.072), without cases of in-hospital thromboembolic complications. The primary endpoint occurred in 29.3% and device-related thrombosis was found in 12.8%, without significant difference according to treatment strategy. Bleeding complications at 18 months occurred in 22.5% vs 10.5% in the IAT and direct LAAC group, respectively (p=0.102). Conclusion: In the presence of LAA thrombus, IAT was the initial management strategy in half of our cohort, with initial thrombus resolution in 60% of these, but with a relatively high bleeding rate (∌10%). Direct LAAC was feasible, with high procedural success and absence of periprocedural embolic complications. However, a high rate of device-related thrombosis was detected during follow-up

    Estimation of Admission D-dimer Cut-off Value to Predict Venous Thrombotic Events in Hospitalized COVID-19 Patients: Analysis of the SEMI-COVID-19 Registry

    Get PDF
    Background: Venous thrombotic events (VTE) are frequent in COVID-19, and elevated plasma D-dimer (pDd) and dyspnea are common in both entities. Objective: To determine the admission pDd cut-off value associated with in-hospital VTE in patients with COVID-19. Methods: Multicenter, retrospective study analyzing the at-admission pDd cut-off value to predict VTE and anticoagulation intensity along hospitalization due to COVID-19. Results: Among 9386 patients, 2.2% had VTE: 1.6% pulmonary embolism (PE), 0.4% deep vein thrombosis (DVT), and 0.2% both. Those with VTE had a higher prevalence of tachypnea (42.9% vs. 31.1%; p = 0.0005), basal O2 saturation &lt;93% (45.4% vs. 33.1%; p = 0.0003), higher at admission pDd (median [IQR]: 1.4 [0.6–5.5] vs. 0.6 [0.4–1.2] ”g/ml; p &lt; 0.0001) and platelet count (median [IQR]: 208 [158–289] vs. 189 [148–245] platelets × 109/L; p = 0.0013). A pDd cut-off of 1.1 ”g/ml showed specificity 72%, sensitivity 49%, positive predictive value (PPV) 4%, and negative predictive value (NPV) 99% for in-hospital VTE. A cut-off value of 4.7 ”g/ml showed specificity of 95%, sensitivity of 27%, PPV of 9%, and NPV of 98%. Overall mortality was proportional to pDd value, with the lowest incidence for each pDd category depending on anticoagulation intensity: 26.3% for those with pDd &gt;1.0 ”g/ml treated with prophylactic dose (p &lt; 0.0001), 28.8% for pDd for patients with pDd &gt;2.0 ”g/ml treated with intermediate dose (p = 0.0001), and 31.3% for those with pDd &gt;3.0 ”g/ml and full anticoagulation (p = 0.0183). Conclusions: In hospitalized patients with COVID-19, a pDd value greater than 3.0 ”g/ml can be considered to screen VTE and to consider full-dose anticoagulation. © 2021, Society of General Internal Medicine

    Measurement of the Bs0→J/ψKS0B_s^0\to J/\psi K_S^0 branching fraction

    Get PDF
    The Bs0→J/ψKS0B_s^0\to J/\psi K_S^0 branching fraction is measured in a data sample corresponding to 0.41fb−1fb^{-1} of integrated luminosity collected with the LHCb detector at the LHC. This channel is sensitive to the penguin contributions affecting the sin2ÎČ\beta measurement from B0→J/ψKS0B^0\to J/\psi K_S^0 The time-integrated branching fraction is measured to be BF(Bs0→J/ψKS0)=(1.83±0.28)×10−5BF(B_s^0\to J/\psi K_S^0)=(1.83\pm0.28)\times10^{-5}. This is the most precise measurement to date

    Measurement of the CP-violating phase \phi s in Bs->J/\psi\pi+\pi- decays

    Get PDF
    Measurement of the mixing-induced CP-violating phase phi_s in Bs decays is of prime importance in probing new physics. Here 7421 +/- 105 signal events from the dominantly CP-odd final state J/\psi pi+ pi- are selected in 1/fb of pp collision data collected at sqrt{s} = 7 TeV with the LHCb detector. A time-dependent fit to the data yields a value of phi_s=-0.019^{+0.173+0.004}_{-0.174-0.003} rad, consistent with the Standard Model expectation. No evidence of direct CP violation is found.Comment: 15 pages, 10 figures; minor revisions on May 23, 201
    • 

    corecore