43 research outputs found

    Spread of a SARS-CoV-2 variant through Europe in the summer of 2020.

    Get PDF
    Following its emergence in late 2019, the spread of SARS-CoV-21,2 has been tracked by phylogenetic analysis of viral genome sequences in unprecedented detail3–5. Although the virus spread globally in early 2020 before borders closed, intercontinental travel has since been greatly reduced. However, travel within Europe resumed in the summer of 2020. Here we report on a SARS-CoV-2 variant, 20E (EU1), that was identified in Spain in early summer 2020 and subsequently spread across Europe. We find no evidence that this variant has increased transmissibility, but instead demonstrate how rising incidence in Spain, resumption of travel, and lack of effective screening and containment may explain the variant’s success. Despite travel restrictions, we estimate that 20E (EU1) was introduced hundreds of times to European countries by summertime travellers, which is likely to have undermined local efforts to minimize infection with SARS-CoV-2. Our results illustrate how a variant can rapidly become dominant even in the absence of a substantial transmission advantage in favourable epidemiological settings. Genomic surveillance is critical for understanding how travel can affect transmission of SARS-CoV-2, and thus for informing future containment strategies as travel resumes. © 2021, The Author(s), under exclusive licence to Springer Nature Limited

    Experimental confirmation of efficient island divertor operation and successful neoclassical transport optimization in Wendelstein 7-X

    Get PDF
    We present recent highlights from the most recent operation phases of Wendelstein 7-X, the most advanced stellarator in the world. Stable detachment with good particle exhaust, low impurity content, and energy confinement times exceeding 100 ms, have been maintained for tens of seconds. Pellet fueling allows for plasma phases with reduced ion-temperature-gradient turbulence, and during such phases, the overall confinement is so good (energy confinement times often exceeding 200 ms) that the attained density and temperature profiles would not have been possible in less optimized devices, since they would have had neoclassical transport losses exceeding the heating applied in W7-X. This provides proof that the reduction of neoclassical transport through magnetic field optimization is successful. W7-X plasmas generally show good impurity screening and high plasma purity, but there is evidence of longer impurity confinement times during turbulence-suppressed phases.EC/H2020/633053/EU/Implementation of activities described in the Roadmap to Fusion during Horizon 2020 through a Joint programme of the members of the EUROfusion consortium/ EUROfusio

    Characterization of branched ultrahigh molar mass polymers by asymmetrical flow field-flow fractionation and size exclusion chromatography

    No full text
    The molar mass distribution (MMD) of synthetic polymers is frequently analyzed by size exclusion chromatography (SEC) coupled to multi angle light scattering (MALS) detection. For ultrahigh molar mass (UHM) or branched polymers this method is not sufficient, because shear degradation and abnormal elution effects falsify the calculated molar mass distribution and information on branching. High temperatures above 130°C have to be applied for dissolution and separation of semi-crystalline materials like polyolefins which requires special hardware setups. Asymmetrical flow field-flow fractionation (AF4) offers the possibility to overcome some of the main problems of SEC due to the absence of an obstructing porous stationary phase. The SEC-separation mainly depends on the pore size distribution of the used column set. The analyte molecules can enter the pores of the stationary phase in dependence on their hydrodynamic volume. The archived separation is a result of the retention time of the analyte species inside SEC-column which depends on the accessibility of the pores, the residence time inside the pores and the diffusion ability of the analyte molecules. The elution order in SEC is typically from low to high hydrodynamic volume. On the contrary AF4 separates according to the diffusion coefficient of the analyte molecules as long as the chosen conditions support the normal FFF-separation mechanism. The separation takes place in an empty channel and is caused by a cross-flow field perpendicular to the solvent flow. The analyte molecules will arrange in different channel heights depending on the diffusion coefficients. The parabolic-shaped flow profile inside the channel leads to different elution velocities. The species with low hydrodynamic volume will elute first while the species with high hydrodynamic volume elute later. The AF4 can be performed at ambient or high temperature (AT-/HT-AF4). We have analyzed one low molar mass polyethylene sample and a number of narrow distributed polystyrene standards as reference materials with known structure by AT/HT-SEC and AT/HT-AF4. Low density polyethylenes as well as polypropylene and polybutadiene, containing high degrees of branching and high molar masses, have been analyzed with both methods. As in SEC the relationship between the radius of gyration (Rg) or the molar mass and the elution volume is curved up towards high elution volumes, a correct calculation of the MMD and the molar mass average or branching ratio is not possible using the data from the SEC measurements. In contrast to SEC, AF4 allows the precise determination of the MMD, the molar mass averages as well as the degree of branching because the molar mass vs. elution volume curve and the conformation plot is not falsified in this technique. In addition, higher molar masses can be detected using HT-AF4 due to the absence of significant shear degradation in the channel. As a result the average molar masses obtained from AF4 are higher compared to SEC. The analysis time in AF4 is comparable to that of SEC but the adjustable cross-flow program allows the user to influence the separation efficiency which is not possible in SEC without a costly change of the whole column combination. © 2011 Elsevier B.V.Articl

    Dye-adsorption-induced gelation of suspensions of spherical and rodlike zinc oxide nanoparticles in organic solvents

    No full text
    The adsorption of amphiphilic Ru-II complex Z907 onto the surface of ZnO nanospheres and nanorods causes the gelation of organic solvents, such as THF and acetone. The gels are thermally stable at very low concentration (nanoparticle volume fraction phi = 0.009) but. mechanically fragile, with the behavior being dependent on the nature of the solvent, nanoparticle concentration, and the Z907/ZnO mole/weight ratio. Rheological experiments confirmed that the solid component built Lip it network to give a viscoelastic. gel-phase material with a weak value of storage modulus G'. However, TEM and SEM experiments did not give evidence that nanoparticle long-range ordering occurred under the experimental conditions investigated. Moreover, time-dependent SAXS measurements pointed to a decrease in the nanoparticle aggregate size upon gelation. All together, the data obtained might be rationalized in terms of the aggregate-to-aggregate transition in solution, with the primitive large aggregates giving rise to smaller ones upon reaction with Z907. The resulting smaller hybrid aggregates could be the active species that act as self-assembling components in the gelation process. Given the interesting electronic and photonic properties of zinc oxide nanoparticles, such hybrid organic-inorganic gels could open new directions in materials science, low-cost electronics, and photovoltaics

    Synthesis, characterization and performance enhancement of dry polyaniline-coated neuroelectrodes for electroencephalography measurement

    No full text
    Originating from a combination of neuroscience and biomedical engineering strategies, neuroprosthetics are developed as substitutes for sensory or cognitive modality damages caused by an injury or a disease. Dry electrodes are essential devices for monitoring of the biopotential such as electroencephalography (EEG) and electrocardiography (ECG). In this paper, polyaniline (PANI) coated stainless steel (SS) electrodes have been fabricated using in-situ electrochemical polymerization on the SS surface. The SEM images showed the formation of a nanoporous PANI-coating on the SS electrodes. EIS measurements on a skin model demonstrated a significantly lower contact impedance for the PANI-coated electrodes compared to bare SS electrodes. Furthermore, increasing the thickness of the nanoporous coating resulted in a higher contact impedance reduction. The comparison of the EEG measurements for the manufactured electrodes with conventional wet Ag/AgCl electrodes showed that the electrodes could successfully monitor alpha rhythms and muscle artifacts, as well. The prepared electrode can be used in various applications such as biopotential monitoring. © 2021 Korean Physical Societ

    Agarose-based biomaterials for advanced drug delivery

    No full text
    Agarose is a prominent marine polysaccharide representing reversible thermogelling behavior, outstanding mechanical properties, high bioactivity, and switchable chemical reactivity for functionalization. As a result, agarose has received particular attention in the fabrication of advanced delivery systems as sophisticated carriers for therapeutic agents. The ever-growing use of agarose-based biomaterials for drug delivery systems resulted in rapid growth in the number of related publications, however still, a long way should be paved to achieve FDA approval for most of the proposed products. This review aims at a classification of agarose-based biomaterials and their derivatives applicable for controlled/targeted drug delivery purposes. Moreover, it attempts to deal with opportunities and challenges associated with the future developments ahead of agarose-based biomaterials in the realm of advanced drug delivery. Undoubtedly, this class of biomaterials needs further advancement, and a lot of critical questions have yet to be answered. © 202
    corecore