126 research outputs found

    Development and Evaluation of an Internet-Based Airway Evaluation Tutorial

    Get PDF
    Airway evaluation and basic management are essential skills for all physicians. Identifying patients for whom mask ventilation or endotracheal intubation will be difficult to impossible is vital for patient safety. Despite this, training in airway evaluation is minimal in the curricula of most medical schools. To ensure a thorough understanding of airway anatomy and evaluation, as well as exposure to various abnormal findings, we developed an Internet-based module including interactive components, graphics, animation, video, and a self-assessment tool. The site received more than 1800 visits in its first nine months of operation, with uniformly laudatory comments. Eighty subjects over a six-month period completed a pre- and post-test quiz structured to evaluate the utility of the site. Of those completing the on-line survey, more than 76% rated the site very useful. Most felt their knowledge of airway examination improved after completion of the site (p<0.00004). The median amount of time spent on the site was 29.5 minutes. Judging from the overwhelming response to this site from around the world and across disciplines, such interactive training tools that exploit the technological capabilities of the Internet provide useful adjuncts to traditional teaching methods

    Development and evaluation of a mechanical ventilator-sharing system

    Get PDF
    BackgroundDuring the COVID-19 pandemic surge in the hospitalization of critically ill patients and the global demand for mechanical ventilators, alternative strategies for device sharing were explored. We developed and assessed the performance of a system for shared ventilation that uses clinically available components to individualize tidal volumes under a variety of clinically relevant conditions. The feasibility of remote monitoring of ventilators was also assessed.MethodsBy using existing resources and off-the-shelf components, a ventilator-sharing system (VSS) that ventilates 2 patients simultaneously with a single device, and a ventilator monitoring system (VMS) that remotely monitors pulmonary mechanics were developed. The feasibility and effectiveness of VSS and VMS were evaluated in benchtop testing using 2 test lungs on a single ventilator, and then performance was assessed in translational swine models of normal and impaired lung function.ResultsIn benchtop testing, VSS and VMS delivered the set individualized parameters with minimal % errors in test lungs under pressure- and volume-regulated ventilation modes, suggesting the highest precision and accuracy. In animal studies, the VSS and VMS successfully delivered the individualized mechanical ventilation parameters within clinically acceptable limits. Further, we found no statistically significant difference between the target and measured values.ConclusionThe VSS adequately ventilated 2 test lungs or animals with variable lung conditions. The VMS accurately displayed mechanical ventilation settings, parameters, and alarms. Both of these systems could be rapidly assembled for scaling up to ventilate several critically ill patients in a pandemic or mass casualty disaster situations by leveraging off-the-shelf and custom 3D printed components

    Emergence of memory

    Full text link
    We propose a new self-organizing mechanism behind the emergence of memory in which temporal sequences of stimuli are transformed into spatial activity patterns. In particular, the memory emerges despite the absence of temporal correlations in the stimuli. This suggests that neural systems may prepare a spatial structure for processing information before the information itself is available. A simple model illustrating the mechanism is presented based on three principles: (1) Competition between neural units, 2) Hebbian plasticity, and (3) recurrent connections.Comment: 7 pages, 4 figures, EPL styl

    Characterization of the effects of Atosiban on uterine electromyograms recorded in women with threatened preterm labor

    Full text link
    [EN] Although research studies using electrohysterography on women without tocolytic therapy have shown its potential for preterm birth diagnosis, tocolytics are usually administered in emergency rooms at the first sign of threatened preterm labor (TPL). Information on the uterine response during tocolytic treatment could prove useful for the development of tools able to predict true preterm deliveries under normal clinical conditions. The aim of this study was thus to analyze the effects of Atosiban on Electrohysterogram (EHG) parameters and to compare its effects on women who delivered preterm (WDP) and at term (WDT). Electrohysterograms recorded in different Atosiban therapy stages (before, during and after drug administration) on 40 WDT and 27 WDP were analyzed by computing linear, and non-linear EHG parameters. Results reveal that Atosiban does not greatly affect the EHG signal amplitude, but does modify its spectral content and reduces the energy associated with the fast wave high component in both WDP and WDT, with a faster response in the latter. EHG signal complexity remained constant in WDT, while it increased in WDP until it reached similar values to WDT during Atosiban treatment. The spectral and complexity parameters were able to separate (p < 0.05) WDT and WDP prior to and during tocolytic treatment and before and after treatment, respectively. The results pave the way for developing better and more reliable medical decision support systems based on EHG for preterm delivery prediction in TPL women in clinical scenarios.This work received financial support from the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R), VLC/Campus (UPV-FE-2018-B03) and by Conselleria de Educación, Investigación, Cultura y Deporte, Generalitat Valenciana (GV/2018/104).Mas-Cabo, J.; Prats-Boluda, G.; Ye Lin, Y.; Alberola Rubio, J.; Perales, A.; Garcia-Casado, J. (2019). Characterization of the effects of Atosiban on uterine electromyograms recorded in women with threatened preterm labor. Biomedical Signal Processing and Control. 52:198-205. https://doi.org/10.1016/j.bspc.2019.04.001S1982055

    Electrohysterographic characterization of the uterine myoelectrical response to labor induction drugs

    Full text link
    [EN] Labor induction is a common practice to promote uterine contractions and labor onset. Uterine electrohysterogram (EHG) has proved its suitability for characterizing the uterus electrophysiological condition in women with spontaneous labor. The aim of this study was to characterize and compare uterine myoelectrical activity during the first 4h in response to labor induction drugs, Misoprostol (G1) and Dinoprostone (G2), by analyzing the differences between women who achieved active phase of labor and those who did not (successful and failed inductions). A set of temporal, spectral and complexity parameters were computed from the EHG-bursts. As for successful inductions, statistical significant and sustained increases with respect to basal period were obtained for EHG amplitude, mean frequency, uterine activity index (UAI) and Teager, after 60¿ for the G1 group; duration, amplitude, number of contractions and UAI for the G2 group, after 120¿. Moreover, Teager showed statistical significant and sustained differences between successful and failed inductions (1.43±1.45 µV2.Hz2.105 vs. 0.40±0.26 µV2.Hz2.105 after 240¿) for the G1 group, but not in the G2 group, probably due to the slower pharmacokinetics of this drug. These results revealed that EHG could be useful for successful induction prediction in the early stages of induction, especially when using Misoprostol.This research project was supported by the Spanish Ministry of Economy and Competitiveness and the European Regional Development Fund (DPI2015-68397-R) and by the company Bial SA.Benalcazar-Parra, C.; Ye Lin, Y.; Garcia Casado, J.; Monfort-Orti, R.; Alberola Rubio, J.; Perales Marín, AJ.; Prats-Boluda, G. (2018). Electrohysterographic characterization of the uterine myoelectrical response to labor induction drugs. Medical Engineering & Physics. 56:27-35. https://doi.org/10.1016/j.medengphy.2018.04.002S27355

    Application of decision tree in determining the importance of surface electrohysterography signal characteristics for recognizing uterine contractions

    Get PDF
    The aims of this study were to apply decision tree to classify uterine activities (contractions and non-contractions) using the waveform characteristics derived from different channels of electrohysterogram (EHG) signals and then rank the importance of these characteristics. Both the tocodynamometer (TOCO) and 8-channel EHG signals were simultaneously recorded from 34 healthy pregnant women within 24 h before delivery. After preprocessing of EHG signals, EHG segments corresponding to the uterine contractions and non-contractions were manually extracted from both original and normalized EHG signals according to the TOCO signals and the human marks. 24 waveform characteristics of the EHG segments were derived separately from each channel to train the decision tree and classify the uterine activities. The results showed the Power and sample entropy (SamEn) extracted from the un-normalized EHG segments played the most important roles in recognizing uterine activities. In addition, the EHG signal characteristics from channel 1 produced better classification results (AUC = 0.75, Sensitivity = 0.84, Specificity = 0.78, Accuracy = 0.81) than the others. In conclusion, decision tree could be used to classify the uterine activities, and the Power and SamEn of un-normalized EHG segments were the most important characteristics in uterine contraction classification

    Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode

    Full text link
    The conduction velocity and propagation patterns of Electrohysterogram (EHG) provide fundamental information about uterine electrophysiological condition. The accuracy of these measurements can be impaired by both the poor spatial selectivity and sensitivity to the relative direction of the contraction propagation associated with conventional disc electrodes. Concentric ring electrodes could overcome these limitations the aim of this study was to examine the feasibility of picking up surface EHG signals using a new flexible tripolar concentric ring electrode (TCRE), and to compare it with conventional bipolar recordings. Simultaneous recording of conventional bipolar signals and bipolar concentric EHG (BC-EHG) were carried out on 22 pregnant women. Signal bursts were characterized and compared. No significant differences among channels in either duration or dominant frequency in the Fast Wave High frequency range were found. Nonetheless, the high pass filtering effect of the BC-EHG records resulted in lower frequency content within the range 0.1 to 0.2 Hz than the bipolar ones. Although the BC-EHG signal amplitude was about 5-7 times smaller than that of bipolar recordings, similar signal-to-noise ratio was obtained. These results suggest that the flexible TCRE is able to pick up uterine electrical activity and could provide additional information for deducing uterine electrophysiological condition.The authors are grateful to the Obstetrics Unit of the Hospital Universitario La Fe de Valencia (Valencia, Spain), where the recording sessions were carried out. The work was supported in part by the Ministerio de Ciencia y Tecnologia de Espana (TEC2010-16945), by the Universitat Politecnica de Valencia (PAID SP20120490) and Generalitat Valenciana (GV/2014/029) and by General Electric Healthcare.Ye Lin, Y.; Alberola Rubio, J.; Prats Boluda, G.; Perales Marin, AJ.; Desantes, D.; Garcia Casado, FJ. (2015). Feasibility and analysis of bipolar concentric recording of Electrohysterogram with flexible active electrode. Annals of Biomedical Engineering. 43(4):968-976. https://doi.org/10.1007/s10439-014-1130-5S968976434Alberola-Rubio, J., G. Prats-Boluda, Y. Ye-Lin, J. Valero, A. Perales, and J. Garcia-Casado. Comparison of non-invasive electrohysterographic recording techniques for monitoring uterine dynamics. Med. Eng. Phys. 35(12):1736–1743, 2013.Besio, W. G., K. Koka, R. Aakula, and W. Dai. Tri-polar concentric ring electrode development for laplacian electroencephalography. IEEE Trans. Biomed. Eng. 53(5):926–933, 2006.Devasahayam, S. R. Signals and Systems in Biomedical Engineering. Berlin: Springer, 2013.Devedeux, D., C. Marque, S. Mansour, G. Germain, and J. Duchene. Uterine electromyography: a critical review. Am. J. Obstet. Gynecol. 169(6):1636–1653, 1993.Estrada, L., A. Torres, J. Garcia-Casado, G. Prats-Boluda, and R. Jane. Characterization of laplacian surface electromyographic signals during isometric contraction in biceps brachii. Conf. Proc. IEEE Eng Med. Biol. Soc. 2013:535–538, 2013.Euliano, T. Y., D. Marossero, M. T. Nguyen, N. R. Euliano, J. Principe, and R. K. Edwards. Spatiotemporal electrohysterography patterns in normal and arrested labor. Am. J. Obstet. Gynecol. 200(1):54–57, 2009.Farina, D., and C. Cescon. Concentric-ring electrode systems for noninvasive detection of single motor unit activity. IEEE Trans. Biomed. Eng. 48(11):1326–1334, 2001.Fele-Zorz, G., G. Kavsek, Z. Novak-Antolic, and F. Jager. A comparison of various linear and non-linear signal processing techniques to separate uterine EMG records of term and pre-term delivery groups. Med. Biol. Eng Comput. 46(9):911–922, 2008.Garfield, R. E., and W. L. Maner. Physiology and electrical activity of uterine contractions. Semin. Cell Dev. Biol. 18(3):289–295, 2007.Garfield, R. E., W. L. Maner, L. B. Mackay, D. Schlembach, and G. R. Saade. Comparing uterine electromyography activity of antepartum patients vs. term labor patients. Am. J. Obstet. Gynecol. 193(1):23–29, 2005.Garfield, R. E., H. Maul, L. Shi, W. Maner, C. Fittkow, G. Olsen, and G. R. Saade. Methods and devices for the management of term and preterm labor. Ann. N. Y. Acad. Sci. 943(1):203–224, 2001.Hassan, M., J. Terrien, C. Muszynski, A. Alexandersson, C. Marque, and B. Karlsson. Better pregnancy monitoring using nonlinear correlation analysis of external uterine electromyography. IEEE Trans. Biomed. Eng. 60(4):1160–1166, 2013.Kaufer, M., L. Rasquinha, and P. Tarjan. Optimization of multi-ring sensing electrode set, Conference proceedings of IEEE Engineering in Medicine and Biology Society, 1990, pp. 612–613.Koka, K., and W. G. Besio. Improvement of spatial selectivity and decrease of mutual information of tri-polar concentric ring electrodes. J. Neurosci. Methods 165(2):216–222, 2007.Lu, C.-C., and P. P. Tarjan. Pasteless, active, concentric ring sensors for directly obtained laplacian cardiac electrograms. J. Med. Biol. Eng. 22(4):199–203, 2002.Lucovnik, M., W. L. Maner, L. R. Chambliss, R. Blumrick, J. Balducci, Z. Novak-Antolic, and R. E. Garfield. Noninvasive uterine electromyography for prediction of preterm delivery. Am. J. Obstet. Gynecol. 204(3):228.e1–228.e10, 2011.Maner, W. L., and R. E. Garfield. Identification of human term and preterm labor using artificial neural networks on uterine electromyography data. Ann. Biomed. Eng. 35(3):465–473, 2007.Maner, W. L., R. E. Garfield, H. Maul, G. Olson, and G. Saade. Predicting term and preterm delivery with transabdominal uterine electromyography. Obstet. Gynecol. 101(6):1254–1260, 2003.Marque, C., J. M. Duchene, S. Leclercq, G. S. Panczer, and J. Chaumont. Uterine EHG processing for obstetrical monitoring. IEEE Trans. Biomed. Eng. 33(12):1182–1187, 1986.Marque, C. K., J. Terrien, S. Rihana, and G. Germain. Preterm labour detection by use of a biophysical marker: the uterine electrical activity. BMC. Pregnancy Childbirth. 7(Suppl1):S5, 2007.Maul, H., W. L. Maner, G. Olson, G. R. Saade, and R. E. Garfield. Non-invasive transabdominal uterine electromyography correlates with the strength of intrauterine pressure and is predictive of labor and delivery. J. Matern. Fetal Neonatal Med. 15(5):297–301, 2004.Miles, A. M., M. Monga, and K. S. Richeson. Correlation of external and internal monitoring of uterine activity in a cohort of term patients. Am. J. Perinatol. 18(3):137–140, 2001.Prats-Boluda, G., J. Garcia-Casado, J. L. Martinez-de-Juan, and Y. Ye-Lin. Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals. Med. Eng. Phys. 33(4):446–455, 2010.Prats-Boluda, G., Y. Ye-Lin, E. Garcia-Breijo, J. Ibañez, and J. Garcia-Casado. Active flexible concentric ring electrode for non-invasive surface bioelectrical recordings. Meas. Sci. Technol. 23(12):1–10, 2012.Rabotti, C., M. Mischi, S. G. Oei, and J. W. Bergmans. Noninvasive estimation of the electrohysterographic action-potential conduction velocity. IEEE Trans. Biomed. Eng. 57(9):2178–2187, 2010.Rabotti, C., S. G. Oei, H. J. van ‘t, and M. Mischi. Electrohysterographic propagation velocity for preterm delivery prediction. Am. J. Obstet. Gynecol. 205(6):e9–e10, 2011.Rooijakkers, M. J., S. Song, C. Rabotti, S. G. Oei, J. W. Bergmans, E. Cantatore, and M. Mischi. Influence of electrode placement on signal quality for ambulatory pregnancy monitoring. Comput. Math. Methods Med. 2014(1):960980, 2014.Schlembach, D., W. L. Maner, R. E. Garfield, and H. Maul. Monitoring the progress of pregnancy and labor using electromyography. Eur. J. Obstet. Gynecol. Reprod. Biol. 144(Suppl1):S33–S39, 2009.Sikora, J., A. Matonia, R. Czabanski, K. Horoba, J. Jezewski, and T. Kupka. Recognition of premature threatening labour symptoms from bioelectrical uterine activity signals. Arch. Perinatal Med. 17(2):97–103, 2011.Terrien, J., C. Marque, and B. Karlsson. Spectral characterization of human EHG frequency components based on the extraction and reconstruction of the ridges in the scalogram, Conference proceedings of IEEE Engineering in Medicine and Biology Society, 2007, pp. 1872–1875.Terrien, J., C. Marque, T. Steingrimsdottir, and B. Karlsson. Evaluation of adaptive filtering methods on a 16 electrode electrohysterogram recorded externally in labor, 11th Mediterranean Conference on Medical and Biomedical Engineering and Computing, 2007, Vol. 16, pp. 135–138.U.S. Preventive Services Task Force. Guide to clinical preventive services: an assessment of the effectiveness of 169 interventions. Baltimore: Willams & Wilkins, 1989
    • …
    corecore