41 research outputs found
Life cycle assessment of the environmental performance of conventional and organic methods of open field pepper cultivation
Summarization: As the scale of the organic cultivation sector keeps increasing, there is growing demand for reliable data on organic agriculture and its effect on the environment. Conventional agriculture uses chemical fertilizers and pesticides, whilst organic cultivation mainly relies on crop rotation and organic fertilizers. The aim of this work is to quantify and compare the environmental sustainability of typical conventional and organic pepper cultivation systems. Methods: Two open field pepper cultivations, both located in the Anthemountas basin, Northern Greece, are selected as case studies. Life cycle assessment (LCA) is used to quantify the overall environmental footprint and identify particular environmental weaknesses (i.e. unsustainable practices) of each cultivation system. Results are analysed at both midpoint and endpoint levels in order to obtain a comprehensive overview of the environmental sustainability of each system. Attributional LCA (ALCA) is employed to identify emissions associated with the life cycles of the two systems. Results are presented for problem-oriented (midpoint) and damage-oriented (endpoint) approaches, using ReCiPe impact assessment. Results and discussion: At midpoint level, conventional cultivation exhibits about threefold higher environmental impact on freshwater eutrophication, than organic cultivation. This arises from the extensive use of nitrogen and phosphorus-based fertilizers, with consequent direct emissions to the environment. The remaining impact categories are mainly affected by irrigation, with associated indirect emissions linked to electricity production. At endpoint level, the main hotspots identified for conventional cultivation are irrigation and fertilizing, due to intensive use of chemical fertilizers and (to a lesser degree) pesticides. For organic pepper cultivation, the main environmental hotspots are irrigation, machinery use, and manure loading and spreading processes. Of these, the highest score for irrigation derives from the heavy electricity consumption required for groundwater pumping associated with the fossil-fuel-dependent Greek electricity mix. Conclusions: Organic and conventional cultivation systems have similar total environmental impacts per unit of product, with organic cultivation achieving lower environmental impacts in ‘freshwater eutrophication’, ‘climate change’, ‘terrestrial acidification’ and ‘marine eutrophication’ categories. Conventional cultivation has a significantly greater effect on the freshwater eutrophication impact category, due to phosphate emissions arising from application of chemical fertilizers.Presented on: International Journal of Life Cycle Assessmen
LCA of greywater management within a water circular economy restorative thinking framework
Greywater reuse is an attractive option for the sustainable management of water under water scarcity circumstances, within a water circular economy restorative thinking framework. Its successful deployment relies on the availability of low cost and environmentally friendly technologies. The life cycle assessment (LCA) approach provides the appropriate methodological tool for the evaluation of alternative treatments based on environmental decision criteria and, therefore, it is highly useful during the process conceptual design. This methodology should be employed in the early design phase to select those technologies with lower environmental impact. This work reports the comparative LCA of three scenarios for greywater reuse: photocatalysis, photovoltaic solar-driven photocatalysis and membrane biological reactor, in order to help the selection of the most environmentally friendly technology. The study has been focused on the removal of the surfactant sodium dodecylbenzenesulfonate, which is used in the formulation of detergents and personal care products and, thus, widely present in greywater. LCA was applied using the Environmental Sustainability Assessment methodology to obtain two main environmental indicators in order to simplify the decision making process: natural resources and environmental burdens. Energy consumption is the main contributor to both indicators owing to the high energy consumption of the light source for the photocatalytic greywater treatment. In order to reduce its environmental burdens, the most desirable scenario would be the use of solar light for the photocatalytic transformation. However, while the technological challenge of direct use of solar light is approached, the environmental suitability of the photovoltaic solar energy driven photocatalysis technology to greywater reuse has been demonstrated, as it involves the smallest environmental impact among the three studied alternatives.Financial support from the Spanish Ministry of Economy and Competitiveness and from FEDER funds for projects CTM2013-43539-R, CTM2015-69845-R and CTQ2015-66078-R(MINECO/FEDER, UE) is gratefully acknowledged. Sara Dominguez and Jara Laso would also like to express their gratitude for the FPI postgraduate research grants (BES-2013-064055 and BES-2014-069368)
Treatment of synthetic textile wastewater containing dye mixtures with microcosms
The aim was to assess the ability of microcosms (laboratory-scale shallow ponds) as a post polishing stage for the remediation of artificial textile wastewater comprising two commercial dyes (basic red 46 (BR46) and reactive blue 198 (RB198)) as a mixture. The objectives were to evaluate the impact of Lemna minor L. (common duckweed) on the water quality outflows; the elimination of dye mixtures, organic matter, and nutrients; and the impact of synthetic textile wastewater comprising dye mixtures on the L. minor plant growth. Three mixtures were prepared providing a total dye concentration of 10 mg/l. Findings showed that the planted simulated ponds possess a significant (p < 0.05) potential for improving the outflow characteristics and eliminate dyes, ammonium-nitrogen (NH4-N), and nitrate-nitrogen (NO3-N) in all mixtures compared with the corresponding unplanted ponds. The removal of mixed dyes in planted ponds was mainly due to phyto-transformation and adsorption of BR46 with complete aromatic amine mineralisation. For ponds containing 2 mg/l of RB198 and 8 mg/l of BR46, removals were around 53%, which was significantly higher than those for other mixtures: 5 mg/l of RB198 and 5 mg/l of BR46 and 8 mg/l of RB198 and 2 mg/l of BR46 achieved only 41 and 26% removals, respectively. Dye mixtures stopped the growth of L. minor, and the presence of artificial wastewater reduced their development
Pseudo-potentiostatic electrolysis by potential buffering induced by the oxygen evolution reaction
A new approach is proposed in order to perform electrochemical oxidation of organics by working under galvanostatic conditions with the potential ‘buffered’ by the competing side reaction of oxygen evolution (OER). According to this process the working potential is fixed by the nature of electrode material and is buffered during organics oxidation by the side reaction of OER. This principle has been used for the selective oxidation of some model organic compounds on Ti/IrO2 anode. Keywords: Pseudo-potentiostatic electrolysis, Oxygen evolution reaction, IrO2 electrode