17 research outputs found

    A European multicentre evaluation of detection and typing methods for human enteroviruses and parechoviruses using RNA transcripts

    Get PDF
    Polymerase chain reaction (PCR) detection has become the gold standard for diagnosis and typing of enterovirus (EV) and human parechovirus (HPeV) infections. Its effectiveness depends critically on using the appropriate sample types and high assay sensitivity as viral loads in cerebrospinal fluid samples from meningitis and sepsis clinical presentation can be extremely low. This study evaluated the sensitivity and specificity of currently used commercial and in-house diagnostic and typing assays. Accurately quantified RNA transcript controls were distributed to 27 diagnostic and 12 reference laboratories in 17 European countries for blinded testing. Transcripts represented the four human EV species (EV-A71, echovirus 30, coxsackie A virus 21, and EV-D68), HPeV3, and specificity controls. Reported results from 48 in-house and 15 commercial assays showed 98% detection frequencies of high copy (1000 RNA copies/5 mu L) transcripts. In-house assays showed significantly greater detection frequencies of the low copy (10 copies/5 mu L) EV and HPeV transcripts (81% and 86%, respectively) compared with commercial assays (56%, 50%; P = 7 x 10(-5)). EV-specific PCRs showed low cross-reactivity with human rhinovirus C (3 of 42 tests) and infrequent positivity in the negative control (2 of 63 tests). Most or all high copy EV and HPeV controls were successfully typed (88%, 100%) by reference laboratories, but showed reduced effectiveness for low copy controls (41%, 67%). Stabilized RNA transcripts provide an effective, logistically simple and inexpensive reagent for evaluation of diagnostic assay performance. The study provides reassurance of the performance of the many in-house assay formats used across Europe. However, it identified often substantially reduced sensitivities of commercial assays often used as point-of-care tests.Peer reviewe

    Re-emergence of enterovirus D68 in Europe after easing the COVID-19 lockdown, September 2021

    Get PDF
    We report a rapid increase in enterovirus D68 (EV-D68) infections, with 139 cases reported from eight European countries between 31 July and 14 October 2021. This upsurge is in line with the seasonality of EV-D68 and was presumably stimulated by the widespread reopening after COVID-19 lockdown. Most cases were identified in September, but more are to be expected in the coming months. Reinforcement of clinical awareness, diagnostic capacities and surveillance of EV-D68 is urgently needed in Europe.Peer Reviewe

    A European multicentre evaluation of detection and typing methods for human enteroviruses and parechoviruses using RNA transcripts

    Get PDF
    Polymerase chain reaction (PCR) detection has become the gold standard for diagnosis and typing of enterovirus (EV) and human parechovirus (HPeV) infections. Its effectiveness depends critically on using the appropriate sample types and high assay sensitivity as viral loads in cerebrospinal fluid samples from meningitis and sepsis clinical presentation can be extremely low. This study evaluated the sensitivity and specificity of currently used commercial and in-house diagnostic and typing assays. Accurately quantified RNA transcript controls were distributed to 27 diagnostic and 12 reference laboratories in 17 European countries for blinded testing. Transcripts represented the four human EV species (EV-A71, echovirus 30, coxsackie A virus 21, and EV-D68), HPeV3, and specificity controls. Reported results from 48 in-house and 15 commercial assays showed 98% detection frequencies of high copy (1000 RNA copies/5 mu L) transcripts. In-house assays showed significantly greater detection frequencies of the low copy (10 copies/5 mu L) EV and HPeV transcripts (81% and 86%, respectively) compared with commercial assays (56%, 50%; P = 7 x 10(-5)). EV-specific PCRs showed low cross-reactivity with human rhinovirus C (3 of 42 tests) and infrequent positivity in the negative control (2 of 63 tests). Most or all high copy EV and HPeV controls were successfully typed (88%, 100%) by reference laboratories, but showed reduced effectiveness for low copy controls (41%, 67%). Stabilized RNA transcripts provide an effective, logistically simple and inexpensive reagent for evaluation of diagnostic assay performance. The study provides reassurance of the performance of the many in-house assay formats used across Europe. However, it identified often substantially reduced sensitivities of commercial assays often used as point-of-care tests

    Molecular epidemiology and evolutionary trajectory of emerging echovirus 30, Europe

    Get PDF
    In 2018, an upsurge in echovirus 30 (E30) infections was reported in Europe. We conducted a large-scale epidemiologic and evolutionary study of 1,329 E30 strains collected in 22 countries in Europe during 2016-2018. Most E30 cases affected persons 0-4 years of age (29%) and 25-34 years of age (27%). Sequences were divided into 6 genetic clades (G1-G6). Most (53%) sequences belonged to G1, followed by G6 (23%), G2 (17%), G4 (4%), G3 (0.3%), and G5 (0.2%). Each clade encompassed unique individual recombinant forms; G1 and G4 displayed >= 2 unique recombinant forms. Rapid turnover of new clades and recombinant forms occurred over time. Clades G1 and G6 dominated in 2018, suggesting the E30 upsurge was caused by emergence of 2 distinct clades circulating in Europe. Investigation into the mechanisms behind the rapid turnover of E30 is crucial for clarifying the epidemiology and evolution of these enterovirus infections.Molecular basis of virus replication, viral pathogenesis and antiviral strategie

    Recommendations for enterovirus diagnostics and characterisation within and beyond Europe

    Get PDF
    Enteroviruses (EV) can cause severe neurological and respiratory infections, and occasionally lead to devastating outbreaks as previously demonstrated with EV-A71 and EV-D68 in Europe. However, these infections are still often underdiagnosed and EV typing data is not currently collected at European level. In order to improve EV diagnostics, collate data on severe EV infections and monitor the circulation of EV types, we have established European non-polio enterovirus network (ENPEN). First task of this cross-border network has been to ensure prompt and adequate diagnosis of these infections in Europe, and hence we present recommendations for nonpolio EV detection and typing based on the consensus view of this multidisciplinary team including experts from over 20 European countries. We recommend that respiratory and stool samples in addition to cerebrospinal fluid (CSF) and blood samples are submitted for EV testing from patients with suspected neurological infections. This is vital since viruses like EV-D68 are rarely detectable in CSF or stool samples. Furthermore, reverse transcriptase PCR (RT-PCR) targeting the 5' noncoding regions (5' NCR) should be used for diagnosis of EVs due to their sensitivity, specificity and short turnaround time. Sequencing of the VP1 capsid protein gene is recommended for EV typing; EV typing cannot be based on the 5' NCR sequences due to frequent recombination events and should not rely on virus isolation. Effective and standardized laboratory diagnostics and characterisation of circulating virus strains are the first step towards effective and continuous surveillance activities, which in turn will be used to provide better estimation on EV disease burden

    The Impact of Borderline Quantiferon-TB Gold Plus Results for Latent Tuberculosis Screening under Routine Conditions in a Low-Endemicity Setting

    No full text
    Quantiferon-TB Gold Plus (QFT-Plus) is an interferon gamma release assay used to diagnose latent tuberculosis (LTB). A borderline range (0.20 to 0.99 IU/ml) around the cutoff (0.35 IU/ml) has been suggested for the earlier QFT version. Our aims were to evaluate the borderline range for QFT-Plus and the contribution of the new TB2 antigen tube. QFT-Plus results were collected from clinical laboratories in Sweden and linked to incident active TB within 3 to 24 months using the national TB registry. Among QFT-Plus results from 58,539 patients, 83% were negative (<0.20 IU/ml), 2.4% were borderline negative (0.20 to 0.34 IU/ml), 3.4% were borderline positive (0.35 to 0.99 IU/ml), 9.6% were positive (≄1.0 IU/ml), and 1.6% were indeterminate. Follow-up tests after initial borderline results were negative (<0.20 IU/ml) in 38.3%, without any cases of incident active TB within 2 years. Applying the 0.35-IU/ml cutoff, 1.5% of TB1 and TB2 results were discrepant, of which 52% were within the borderline range. A TB2 result of ≄0.35 IU/ml with a TB1 result of <0.20 IU/ml was found in 0.4% (231/58,539) of all included baseline QFT-Plus test results, including 1.8% (1/55) of incident TB cases. A borderline range for QFT-Plus is clinically useful as more than one-third of those with borderline results are convincingly negative upon retesting, without developing incident active TB. The TB2 tube contribution to LTB diagnosis appears limited

    Molecular epidemiology and evolutionary trajectory of emerging echovirus 30, Europe

    No full text
    In 2018, an upsurge in echovirus 30 (E30) infections was reported in Europe. We conducted a large-scale epidemiologic and evolutionary study of 1,329 E30 strains collected in 22 countries in Europe during 2016–2018. Most E30 cases affected persons 0–4 years of age (29%) and 25–34 years of age (27%). Sequences were divided into 6 genetic clades (G1–G6). Most (53%) sequences belonged to G1, followed by G6 (23%), G2 (17%), G4 (4%), G3 (0.3%), and G5 (0.2%). Each clade encompassed unique individual recombinant forms; G1 and G4 displayed >2 unique recombinant forms. Rapid turnover of new clades and recombinant forms occurred over time. Clades G1 and G6 dominated in 2018, suggesting the E30 upsurge was caused by emergence of 2 distinct clades circulating in Europe. Investigation into the mechanisms behind the rapid turnover of E30 is crucial for clarifying the epidemiology and evolution of these enterovirus infections

    A European multicentre evaluation of detection and typing methods for human enteroviruses and parechoviruses using RNA transcripts

    No full text
    Polymerase chain reaction (PCR) detection has become the gold standard for diagnosis and typing of enterovirus (EV) and human parechovirus (HPeV) infections. Its effectiveness depends critically on using the appropriate sample types and high assay sensitivity as viral loads in cerebrospinal fluid samples from meningitis and sepsis clinical presentation can be extremely low. This study evaluated the sensitivity and specificity of currently used commercial and in‐house diagnostic and typing assays. Accurately quantified RNA transcript controls were distributed to 27 diagnostic and 12 reference laboratories in 17 European countries for blinded testing. Transcripts represented the four human EV species (EV‐A71, echovirus 30, coxsackie A virus 21, and EV‐D68), HPeV3, and specificity controls. Reported results from 48 in‐house and 15 commercial assays showed 98% detection frequencies of high copy (1000 RNA copies/5 ”L) transcripts. In‐house assays showed significantly greater detection frequencies of the low copy (10 copies/5 ”L) EV and HPeV transcripts (81% and 86%, respectively) compared with commercial assays (56%, 50%; P = 7 × 10−5). EV‐specific PCRs showed low cross‐reactivity with human rhinovirus C (3 of 42 tests) and infrequent positivity in the negative control (2 of 63 tests). Most or all high copy EV and HPeV controls were successfully typed (88%, 100%) by reference laboratories, but showed reduced effectiveness for low copy controls (41%, 67%). Stabilized RNA transcripts provide an effective, logistically simple and inexpensive reagent for evaluation of diagnostic assay performance. The study provides reassurance of the performance of the many in‐house assay formats used across Europe. However, it identified often substantially reduced sensitivities of commercial assays often used as point‐of‐care tests
    corecore