142 research outputs found

    Liposome encapsulation of fluorescent nanoparticles: Quantum dots and silica nanoparticles

    Get PDF
    Quantum dots (QDs) and silica nanoparticles (SNs) are relatively new classes of fluorescent probes that overcome the limitations encountered by organic fluorophores in bioassay and biological imaging applications. We encapsulated QDs and SNs in liposomes and separated nanoparticle-loaded liposomes from unencapsulated nanoparticles by size exclusion chromatography. Fluorescence correlation spectroscopy was used to measure the average number of nanoparticles inside each liposome. Results indicated that nanoparticle-loaded liposomes were formed and separated from unencapsulated nanoparticles by using a Sepharose gel. As expected, fluorescence self-quenching of nanoparticles inside liposomes was not observed. Each liposome encapsulated an average of three QDs. These studies demonstrated that nanoparticles could be successfully encapsulated into liposomes and provided a methodology to quantify the number of nanoparticles inside each liposome by fluorescence correlation spectroscop

    Ganglioside-liposome immunoassay for the detection of botulinum toxin

    Get PDF
    A rapid and highly sensitive receptor immunoassay for botulinum toxin (BT) has been developed using ganglioside-incorporated liposomes. Botulism outbreaks are relatively rare, but their results can be very severe, usually leading to death from respiratory failure. To exert their toxicity, the biological toxins must first bind to receptors on the cell surface, and the trisialoganglioside GT1b has been identified as the cell receptor for BT. Therefore, in this study, GT1b was used to prepare the ganglioside-liposomes by spontaneous insertion into the phospholipid bilayer. In a sandwich-based, hybrid receptor immunoassay, BT is detected as a colored band on a nitrocellulose membrane strip, where BT bound to the GT1b-liposomes are captured by anti-BT antibodies immobilized in a band across the strip. The intensity of the colored band can be visually estimated, or measured by densitometry using computer software. The limit of detection (LOD) for BT in the lateral-flow assay system was 15pgmL−1, which is comparable to the limits of detection achieved with the most sensitive assays previously reported. However, this rapid assay can be completed in less than 20min. These results demonstrate that the sandwich assay using GT1b-liposomes for detection of BT is rapid and very sensitive, suggesting the possibility for detecting BT in field screening, simply and reliably, without the need for complex instrumentatio

    Electrochemical biosensors: recommended definitions and classification

    Get PDF
    International audienceTwo Divisions of the International Union of Pure and Applied Chemistry (IUPAC), namely Physical Chemistry (Commission I.7 on Biophysical Chemistry, formerly Steering Committee on Biophysical Chemistry) and Analytical Chemistry (Commission V.5 on Electroanalytical Chemistry), have prepared recommendations on the definition, classification and nomenclature related to electrochemical biosensors; these recommendations could, in the future, be extended to other types of biosensors. An electrochemical biosensor is a self-contained integrated device, which is capable of providing specific quantitative or semi-quantitative analytical information using a biological recognition element (biochemical receptor) which is retained in direct spatial contact with an electrochemical transduction element. Because of their ability to be repeatedly calibrated, we recommend that a biosensor should be clearly distinguished from a bioanalytical system, which requires additional processing steps, such as reagent addition. A device which is both disposable after one measurement, i.e. single use, and unable to monitor the analyte concentration continuously or after rapid and reproducible regeneration should be designated a single-use biosensor. Biosensors may be classified according to the biological specificity-conferring mechanism or, alternatively, the mode of physicochemical signal transduction. The biological recognition element may be based on a chemical reaction catalysed by, or on an equilibrium reaction with, macromolecules that have been isolated, engineered or present in their original biological environment. In the latter case, equilibrium is generally reached and there is no further, if any, net consumption of analyte(s) by the immobilized biocomplexing agent incorporated into the sensor. Biosensors may be further classi®ed according to the analytes or reactions that they monitor: direct monitoring of analyte concentration or of reactions producing or consuming such analytes; alternatively, an indirect monitoring of inhibitor or activator of the biological recognition element (biochemical receptor) may be achieved. A rapid proliferation of biosensors and their diversity has led to a lack of rigour in defining their performance criteria. Although each biosensor can only truly be evaluated for a particular application, it is still useful to examine how standard protocols for performance criteria may be defined in accordance with standard IUPAC protocols or definitions. These criteria are recommended for authors, referees and educators and include calibration characteristics (sensitivity, operational and linear concentration range, detection and quantitative determination limits), selectivity, steady-state and transient response times, sample throughput, reproducibility, stability and lifetime

    Electrochemical biosensors: recommended definitions and classification

    Get PDF
    International audienceTwo Divisions of the International Union of Pure and Applied Chemistry (IUPAC), namely Physical Chemistry (Commission I.7 on Biophysical Chemistry formerly Steering Committee on Biophysical Chemistry) and Analytical Chemistry (Commission V.5 on Electroanalytical Chemistry) have prepared recommendations on the definition, classification and nomenclature related to electrochemical biosensors; these recommendations could, in the future, be extended to other types of biosensors. An electrochem-ical biosensor is a self-contained integrated device, which is capable of providing specific quantitative or semi-quantitative analytical information using a biological recognition element (biochemical receptor) which is retained in direct spatial contact with an electrochemical transduction element. Because of their ability to be repeatedly calibrated, we recommend that a biosensor should be clearly distinguished from a bioanalytical system, which requires additional processing steps, such as reagent addition. A device that is both disposable after one measurement, i.e. single use, and unable to monitor the analyte concentration continuously or after rapid and reproducible regeneration, should be designated a single use biosensor. Biosensors may be classified according to the biological specificity-conferring mechanism or, alternatively, to the mode of physico-chemical signal transduction. The biological recognition element may be based on a chemical reaction catalysed by, or on an equilibrium reaction with macromolecules that have been isolated, engineered or present in their original biological environment. In the latter cases, equilibrium is generally reached and there is no further, if any, net consumption of analyte(s) by the immobilized biocomplexing agent incorporated into the sensor. Biosensors may be further classified according to the analytes or reactions that they monitor: direct monitoring of analyte concentration or of reactions producing or consuming such analytes; alternatively, an indirect monitoring of inhibitor or activator of the biological recognition element (biochemical receptor) may be achieved. A rapid proliferation of biosensors and their diversity has led to a lack of rigour in defining their performance criteria. Although each biosensor can only truly be evaluated for a particular application, it is still useful to examine how standard protocols for performance criteria may be defined in accordance with standard IUPAC protocols or definitions. These criteria are recommended for authors, referees and educators and include calibration characteristics (sensitivity, operational and linear concentration range, detection and quantitative determination limits), selectivity, steady-state and transient response times, sample throughput, reproducibility, stability and lifetime

    Development of a competitive liposome-based lateral flow assay for the rapid detection of the allergenic peanut protein Ara h1

    Get PDF
    A competitive lateral flow assay for detecting the major peanut allergen, Ara h1, has been developed. The detector reagents are Ara h1-tagged liposomes, and the capture reagents are anti-Ara h1 polyclonal antibodies. Two types of rabbit polyclonal antibodies were raised either against the entire Ara h1 molecules (anti-Ara h1 Ab) or against an immunodominant epitope on Ara h1 (anti-peptide Ab). All of them reacted specifically with Ara h1 in Western Blot against crude peanut proteins. Moreover, the anti-Ara h1 Ab was chosen for this assay development because of its highest immunoactivity to Ara h1-tagged liposomes in the lateral flow assay. The calculated limit of detection (LOD) of this assay is 0.45μgmL−1 of Ara h1 with a dynamic range between 0.1 and 10μgmL−1 of Ara h1 in buffer. Additionally, the visually determined detection range is from 1 to 10μgmL−1 of Ara h1 in buffer. Results using this assay can be obtained within 30min without the need of sophisticated equipment or techniques; therefore, this lateral flow assay has the potential to be a cost-effective, fast, simple, and sensitive method for on-site screening of peanut allergen

    A novel extraction method for peanut allergenic proteins in chocolate and their detection by a liposome-based lateral flow assay

    Get PDF
    In this study, conditions for extracting the major peanut allergen (Ara h1) from chocolate were optimized, and the extracted samples were analyzed by a lateral flow assay (LFA) using liposomal nanovesicles. The optimal conditions using peanut-spiked chocolate were found to be extraction with a mixture of phosphate buffered saline and hexane for 30min at 35°C. After centrifugation, the buffer portion was treated with insoluble poly(vinylpolypyrrolidone) to remove phenolic compounds, and then analyzed by the LFA. The entire analysis, including sample preparation and LFA, could be easily completed within 2h, and the detection limit was 158μg of peanuts/g of chocolat

    Electrochemical Biosensors: Recommended Definitions and Classification

    Get PDF
    Two Divisions of the International Union of Pure and Applied Chemistry (IUPAC), namely Physical Chemistry (Commission I.7 on Biophysical Chemistry, formerly Steering Committee on Biophysical Chemistry) and Analytical Chemistry (Commission V.5 on Electroanalytical Chemistry), have prepared recommendations on the definition, classification and nomenclature related to electrochemical biosensors; these recommendations could, in the future, be extended to other types of biosensors. An electrochemical biosensor is a self-contained integrated device, which is capable of providing specific quantitative or semi-quantitative analytical information using a biological recognition element (biochemical receptor) which is retained in direct spatial contact with an electrochemical transduction element. Because of their ability to be repeatedly calibrated, we recommend that a biosensor should be clearly distinguished from a bioanalytical system, which requires additional processing steps, such as reagent addition. A device which is both disposable after one measurement, i.e. single use, and unable to monitor the analyte concentration continuously or after rapid and reproducible regeneration should be designated a single-use biosensor. Biosensors may be classified according to the biological specificity-conferring mechanism or, alternatively, the mode of physicochemical signal transduction. The biological recognition element may be based on a chemical reaction catalysed by, or on an equilibrium reaction with, macromolecules that have been isolated, engineered or present in their original biological environment. In the latter case, equilibrium is generally reached and there is no further, if any, net consumption of analyte(s) by the immobilized biocomplexing agent incorporated into the sensor. Biosensors may be further classified according to the analytes or reactions that they monitor: direct monitoring of analyte concentration or of reactions producing or consuming such analytes; alternatively, an indirect monitoring of inhibitor or activator of the biological recognition element (biochemical receptor) may be achieved. A rapid proliferation of biosensors and their diversity has led to a lack of rigour in defining their performance criteria. Although each biosensor can only truly be evaluated for a particular application, it is still useful to examine how standard protocols for performance criteria may be defined in accordance with standard IUPAC protocols or definitions. These criteria are recommended for authors, referees and educators and include calibration characteristics (sensitivity, operational and linear concentration range, detection and quantitative determination limits), selectivity, steady-state and transient response times, sample throughput, reproducibility, stability and lifetime

    Surrogate endpoint biomarkers for cervical cancer chemoprevention trials

    Full text link
    Cervical intraepithelia neoplasia (CIN) represents a spectrum of epithelial changes that provide an excellent model for developing chemopreventive interventions for cervical cancer. Possible drug effect surrogate endpoint biomarkers are dependent on the agent under investigation. Published and preliminary clinical reports suggest retinoids and carotenoids are effective chemopreventive agents for CIN. Determination of plasma and tissue pharmacology of these agents and their metabolites could serve as drug effect intermediate endpoints. In addition, retinoic acid receptors could serve as both drug and biological effect intermediate endpoints. Possible biological effect surrogate endpoint biomarkers include cytomorphological parameters, proliferation markers, genomic markers, regulatory markers, and differentiation. Given the demonstrated causality of human papillomavirus (HPV) for cervical cancer, establishing the relationship to HPV will be an essential component of any biological intermediate endpoint biomarker. The pathologic effect surrogate endpoint biomarker for cervical cancer is CIN, used clinically for years. The desired effect for chemopreventive trials is complete regression or prevention of progression. In planning chemopreventive trials, investigators need to consider spontaneous regression rates, the subjective nature of detecting CIN, and the impact of biopsy on regression. If intermediate endpoint biomarkers that met the above criteria were available for cervical cancer, then new chemopreventive agents could be rapidly explored. The efficacy of these new agents could be determined with a moderate number of subjects exposed to minimal risk over an acceptable amount of time. The impacts on health care for women would be significant.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/38459/1/240590915_ftp.pd

    The impact of type of dietary protein, animal versus vegetable, in modifying cardiometabolic risk factors: A position paper from the International Lipid Expert Panel (ILEP)

    Get PDF
    Proteins play a crucial role in metabolism, in maintaining fluid and acid-base balance and antibody synthesis. Dietary proteins are important nutrients and are classified into: 1) animal proteins (meat, fish, poultry, eggs and dairy), and, 2) plant proteins (legumes, nuts and soy). Dietary modification is one of the most important lifestyle changes that has been shown to significantly decrease the risk of cardiovascular (CV) disease (CVD) by attenuating related risk factors. The CVD burden is reduced by optimum diet through replacement of unprocessed meat with low saturated fat, animal proteins and plant proteins. In view of the available evidence, it has become acceptable to emphasize the role of optimum nutrition to maintain arterial and CV health. Such healthy diets are thought to increase satiety, facilitate weight loss, and improve CV risk. Different studies have compared the benefits of omnivorous and vegetarian diets. Animal protein related risk has been suggested to be greater with red or processed meat over and above poultry, fish and nuts, which carry a lower risk for CVD. In contrast, others have shown no association of red meat intake with CVD. The aim of this expert opinion recommendation was to elucidate the different impact of animal vs vegetable protein on modifying cardiometabolic risk factors. Many observational and interventional studies confirmed that increasing protein intake, especially plant-based proteins and certain animal-based proteins (poultry, fish, unprocessed red meat low in saturated fats and low-fat dairy products) have a positive effect in modifying cardiometabolic risk factors. Red meat intake correlates with increased CVD risk, mainly because of its non-protein ingredients (saturated fats). However, the way red meat is cooked and preserved matters. Thus, it is recommended to substitute red meat with poultry or fish in order to lower CVD risk. Specific amino acids have favourable results in modifying major risk factors for CVD, such as hypertension. Apart from meat, other animal-source proteins, like those found in dairy products (especially whey protein) are inversely correlated to hypertension, obesity and insulin resistance
    • …
    corecore