110 research outputs found

    Treatment of long-term stored DNA- Comparison between different methods to obtain high-quality materia

    Get PDF
    Long-term stored DNA can be sometimes the only source of genetic material of an organism that does not exist anymore, but a research interest still persists. However, there is a lack of information about useful methods to improve quality from such type of material. In this study, we compared four different protocols using DNA samples collected in 1998. Fresh DNA was also tested aiming to check the differences between these two material types. Sixteen samples of each DNA type treated with phenol-chloroform with PEG 5.0%, silica-gel membrane spin column, PEG 7.5%, and glass-fiber matrix spin column were submitted to spectrophotometer measurements, electrophoresis, PCR, and RFLP-PCR to assess the best method concerning yield, quality, and purity. Based on the results, purification with PEG 7.5% was considered the best method to treat aged DNA samples. In addition to the efficiency, this protocol has low cost. Analyzing the data, we also conclude that long-term stored DNA may be considered a reliable and potential resource for future molecular studies.Long-term stored DNA can be sometimes the only source of genetic material of an organism that does not exist anymore, but a research interest still persists. However, there is a lack of information about useful methods to improve quality from such type of material. In this study, we compared four different protocols using DNA samples collected in 1998. Fresh DNA was also tested aiming to check the differences between these two material types. Sixteen samples of each DNA type treated with phenol-chloroform with PEG 5.0%, silica-gel membrane spin column, PEG 7.5%, and glass-fiber matrix spin column were submitted to spectrophotometer measurements, electrophoresis, PCR, and RFLP-PCR to assess the best method concerning yield, quality, and purity. Based on the results, purification with PEG 7.5% was considered the best method to treat aged DNA samples. In addition to the efficiency, this protocol has low cost. Analyzing the data, we also conclude that long-term stored DNA may be considered a reliable and potential resource for future molecular studies

    Caracterização do Público Lojista de um Centro de Compras no Agreste das Confecções: Tendências Disposicionais e Tensões Administrativas.

    Get PDF
    Este artigo visa avançar no sentido da caracterização do público lojista, proprietários de negócios e gerentes-responsáveis, de um centro de compras situado em uma região específica do interior do Nordeste brasileiro. Por meio de uma leitura contextualizada da noção de habitus (Bourdieu), toma como objetivos específicos: (1) explorar similaridades e diferenças, em termos de tendências disposicionais administrativas, no referido público; e (2) identificar possíveis focos disposicionais para a tensão existente entre tal público e a administração do empreendimento. Trata-se de um estudo exploratório, onde foram realizadas 159 entrevistas e observações de campo de inspiração etnográfica. Os resultados identificaram três tendências disposicionais administrativas que parecem ser significativamente recorrentes entre os pesquisados, a saber: a) manutenção de práticas próximas à administração-feirante; b) adaptação ao novo ambiente de negócios; e c) hibridismos administrativos

    Reference gene selection for quantitative PCR in liver, skeletal muscle, and jejunum of Bos indicus cattle

    Get PDF
    ABSTRACT The objective of the present study was to evaluate the stability of candidate reference genes and select the genes that can be used for normalizing real-time polymerase chain reaction (PCR) in the liver, skeletal muscle, and jejunum tissues of Nellore or Nellore × Angus steers fed different diets. Fourteen purebred and 14 crossbred steers were used, in which half of the animals of each genetic group received a diet containing whole shelled corn (WSC) and the other half whole shelled corn and sugarcane bagasse (WSCB). Stability was analyzed by the RefFinder program. To validate the selection of candidate reference genes, the expression of target genes was evaluated using the different groups of reference genes. The most stable genes were 18S, ACTB, and CASC3 for skeletal muscle; HMBS, ACTB, and 18S for the liver; and GAPDH, ACTB, and CASC3 for the jejunum, regardless of breed and diet provided. Possible errors caused in data analyses were clarified comparing the more and less stable genes as reference for normalization of the target genes FASN, ACOX, SCD1, MGAM, and SLC2A1. The use of the more stable and less stable sets of reference genes may lead to different conclusions in respect to the expression profile of the target studied gene. The selection of more suitable reference genes for each experiment is of utmost importance to ensure the reliability of gene expression studies so that they can be applied in practice

    Identification of suitable reference genes for real time quantitative polymerase chain reaction assays on pectoralis major muscle in chicken (Gallus gallus)

    Get PDF
    Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqCoordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPESFundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SEThirteen reference genes were investigated to determine their stability to be used as a housekeeping in gene expression studies in skeletal muscle of chickens. Five different algorithms were used for ranking of reference genes and results suggested that individual rankings of the genes differed among them. The stability of the expression of reference genes were validated using samples obtained from the Pectoralis major muscle in chicken. Samples were obtained from chickens in different development periods post hatch and under different nutritional diets. For gene expression calculation the ΔΔCt approach was applied to compare relative expression of pairs of genes within each of 52 samples when normalized to mitochondrially encoded cytochrome c oxidase II (MT-CO2) target gene. Our findings showed that hydroxymethylbilane synthase (HMBS) and hypoxanthine phosphoribosyl transferase 1 (HPRT1) are the most stable reference genes while transferrin receptor (TFRC) and beta-2-microglobulin (B2M) ranked as the least stable genes in the Pectoralis major muscle of chickens. Moreover, our results revealed that HMBS and HPRT1 gene expression did not change due to dietary variations and thus it is recommended for accurate normalization of RT-qPCR data in chicken Pectoralis major muscle

    Thalidomide plus dexamethasone as a maintenance therapy after autologous hematopoietic stem cell transplantation improves progression-free survival in multiple myeloma

    Get PDF
    Despite the good response of stem cell transplant (SCT) in the treatment of multiple myeloma (MM), most patients relapse or do not achieve complete remission, suggesting that additional treatment is needed. We assessed the impact of thalidomide in maintenance after SCT in untreated patients with MM. A hundred and eight patients (<70 years old) were randomized to receive maintenance with dexamethasone (arm A; n = 52) or dexamethasone with thalidomide (arm B; n = 56; 200 mg daily) for 12 months or until disease progression. After a median follow-up of 27 months, an intention to treat analysis showed a 2-year progression-free survival (PFS) of 30% in arm A (95% CI 2238) and 64% in arm B (95% CI 5771; P = 0.002), with median PFS of 19 months and 36 months, respectively. In patients who did not achieve at least a very good partial response, the PFS at 2 years was significantly higher when in use of thalidomide (19 vs. 59%; P = 0.002). Overall survival at 2 years was not significantly improved (70 vs. 85% in arm A and arm B, respectively; P = 0.27). The addition of thalidomide to dexamethasone as maintenance improved the PFS mainly in patients who did not respond to treatment after SCT. Am. J. Hematol. (c) 2012 Wiley Periodicals, Inc.FAPESP (Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)CNPq (Conselho Nacional do Desenvolvimento Cientifico e Tecnologico)Conselho Nacional do Desenvolvimento Cientifico e Tecnologico (CNPq)FAPERJ (Fundacao de Apoio a Pesquisa do Estado do Rio de Janeiro)FAPERJ (Fundacao de Apoio a Pesquisa do Estado do Rio de Janeiro

    Pervasive gaps in Amazonian ecological research

    Get PDF
    Biodiversity loss is one of the main challenges of our time,1,2 and attempts to address it require a clear un derstanding of how ecological communities respond to environmental change across time and space.3,4 While the increasing availability of global databases on ecological communities has advanced our knowledge of biodiversity sensitivity to environmental changes,5–7 vast areas of the tropics remain understudied.8–11 In the American tropics, Amazonia stands out as the world’s most diverse rainforest and the primary source of Neotropical biodiversity,12 but it remains among the least known forests in America and is often underrepre sented in biodiversity databases.13–15 To worsen this situation, human-induced modifications16,17 may elim inate pieces of the Amazon’s biodiversity puzzle before we can use them to understand how ecological com munities are responding. To increase generalization and applicability of biodiversity knowledge,18,19 it is thus crucial to reduce biases in ecological research, particularly in regions projected to face the most pronounced environmental changes. We integrate ecological community metadata of 7,694 sampling sites for multiple or ganism groups in a machine learning model framework to map the research probability across the Brazilian Amazonia, while identifying the region’s vulnerability to environmental change. 15%–18% of the most ne glected areas in ecological research are expected to experience severe climate or land use changes by 2050. This means that unless we take immediate action, we will not be able to establish their current status, much less monitor how it is changing and what is being lostinfo:eu-repo/semantics/publishedVersio

    Pervasive gaps in Amazonian ecological research

    Get PDF

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento
    corecore