592 research outputs found

    Extinction of the N=20 neutron-shell closure for 32Mg examined by direct mass measurements

    Full text link
    The 'island of inversion' around 32^{32}Mg is one of the most important paradigm for studying the disappearance of the stabilizing 'magic' of a shell closure. We present the first Penning-trap mass measurements of the exotic nuclides 29−31^{29-31}Na and 30−34^{30-34}Mg, which allow a precise determination of the empirical shell gap for 32^{32}Mg. The new value of 1.10(3) MeV is the lowest observed shell gap for any nuclide with a canonical magic number.Comment: 6 pages, 4 figures, submitted to Physical Review

    Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states

    Full text link
    The use of highly charged ions increases the precision and resolving power, in particular for short-lived species produced at on-line radio-isotope beam facilities, achievable with Penning trap mass spectrometers. This increase in resolving power provides a new and unique access to resolving low-lying long-lived (T1/2>50T_{1/2} > 50 ms) nuclear isomers. Recently, the 111.19(22)111.19(22) keV (determined from γ\gamma-ray spectroscopy) isomeric state in 78^{78}Rb has been resolved from the ground state, in a charge state of q=8+q=8+ with the TITAN Penning trap at the TRIUMF-ISAC facility. The excitation energy of the isomer was measured to be 108.7(6.4)108.7(6.4) keV above the ground state. The extracted masses for both the ground and isomeric states, and their difference, agree with the AME2003 and Nuclear Data Sheet values. This proof of principle measurement demonstrates the feasibility of using Penning trap mass spectrometers coupled to charge breeders to study nuclear isomers and opens a new route for isomer searches.Comment: 8 pages, 6 figure

    Low-Background In-Trap Decay Spectroscopy with TITAN at TRIUMF

    Get PDF
    An in-trap decay spectroscopy setup has been developed and constructed for use with the TITAN facility at TRIUMF. The goal of this device is to observe weak electron-capture (EC) branching ratios for the odd-odd intermediate nuclei in the ββ\beta\beta decay process. This apparatus consists of an up-to 6 Tesla, open-access spectroscopy ion-trap, surrounded radially by up to 7 planar Si(Li) detectors which are separated from the trap by thin Be windows. This configuration provides a significant increase in sensitivity for the detection of low-energy photons by providing backing-free ion storage and eliminating charged-particle-induced backgrounds. An intense electron beam is also employed to increase the charge-states of the trapped ions, thus providing storage times on the order of minutes, allowing for decay-spectroscopy measurements. The technique of multiple ion-bunch stacking was also recently demonstrated, which further extends the measurement possibilities of this apparatus. The current status of the facility and initial results from a 116^{116}In measurement are presented.Comment: Proceedings for the 2nd International Conference on Advances in Radioactive Isotope Science (ARIS2014

    First direct mass-measurement of the two-neutron halo nucleus 6He and improved mass for the four-neutron halo 8He

    Full text link
    The first direct mass-measurement of 6^{6}He has been performed with the TITAN Penning trap mass spectrometer at the ISAC facility. In addition, the mass of 8^{8}He was determined with improved precision over our previous measurement. The obtained masses are mm(6^{6}He) = 6.018 885 883(57) u and mm(8^{8}He) = 8.033 934 44(11) u. The 6^{6}He value shows a deviation from the literature of 4σ\sigma. With these new mass values and the previously measured atomic isotope shifts we obtain charge radii of 2.060(8) fm and 1.959(16) fm for 6^{6}He and 8^{8}He respectively. We present a detailed comparison to nuclear theory for 6^6He, including new hyperspherical harmonics results. A correlation plot of the point-proton radius with the two-neutron separation energy demonstrates clearly the importance of three-nucleon forces.Comment: 4 pages, 2 figure

    First Penning-trap mass measurement in the millisecond half-life range: the exotic halo nucleus 11Li

    Full text link
    In this letter, we report a new mass for 11^{11}Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, t1/2=8.8mst_{1/2} = 8.8 \rm{ms}, for which a mass measurement has ever been performed with a Penning trap. Combined with our mass measurements of 8,9^{8,9}Li we derive a new two-neutron separation energy of 369.15(65) keV: a factor of seven more precise than the best previous value. This new value is a critical ingredient for the determination of the halo charge radius from isotope-shift measurements. We also report results from state-of-the-art atomic-physics calculations using the new mass and extract a new charge radius for 11^{11}Li. This result is a remarkable confluence of nuclear and atomic physics.Comment: Formatted for submission to PR

    Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements

    Full text link
    A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of ββ\beta\beta decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of 124^{124}Cs.Comment: 9 pages, 9 figure

    TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance

    Full text link
    We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage (Vpp=400 VV_{pp} = \rm{400 \, V}), wide bandwidth (0.2<f<1.2 MHz0.2 < f < 1.2 \, \rm{MHz}) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable 133^{133}Cs and radioactive 124,126^{124, 126}Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.Comment: 34 pages, 17 figure

    Breakdown of the Isobaric Multiplet Mass Equation for the A = 20 and 21 Multiplets

    Full text link
    Using the Penning trap mass spectrometer TITAN, we performed the first direct mass measurements of 20,21Mg, isotopes that are the most proton-rich members of the A = 20 and A = 21 isospin multiplets. These measurements were possible through the use of a unique ion-guide laser ion source, a development that suppressed isobaric contamination by six orders of magnitude. Compared to the latest atomic mass evaluation, we find that the mass of 21Mg is in good agreement but that the mass of 20Mg deviates by 3{\sigma}. These measurements reduce the uncertainties in the masses of 20,21Mg by 15 and 22 times, respectively, resulting in a significant departure from the expected behavior of the isobaric multiplet mass equation in both the A = 20 and A = 21 multiplets. This presents a challenge to shell model calculations using either the isospin non-conserving USDA/B Hamiltonians or isospin non-conserving interactions based on chiral two- and three-nucleon forces.Comment: 5 pages, 2 figure
    • …
    corecore