12 research outputs found
Correction to: Abstracts from the NIHR INVOLVE Conference 2017.
[This corrects the article DOI: 10.1186/s40900-017-0075-x.]
Bioterrorism-related Inhalational Anthrax in an Elderly Woman, Connecticut, 2001
On November 20, 2001, inhalational anthrax was confirmed in an elderly woman from rural Connecticut. To determine her exposure source, we conducted an extensive epidemiologic, environmental, and laboratory investigation. Molecular subtyping showed that her isolate was indistinguishable from isolates associated with intentionally contaminated letters. No samples from her home or community yielded Bacillus anthracis, and she received no first-class letters from facilities known to have processed intentionally contaminated letters. Environmental sampling in the regional Connecticut postal facility yielded B. anthracis spores from 4 (31%) of 13 sorting machines. One extensively contaminated machine primarily processes bulk mail. A second machine that does final sorting of bulk mail for her zip code yielded B. anthracis on the column of bins for her carrier route. The evidence suggests she was exposed through a cross-contaminated bulk mail letter. Such cross-contamination of letters and postal facilities has implications for managing the response to future B. anthracis–contaminated mailings
Effects of a high-dose 24-h infusion of tranexamic acid on death and thromboembolic events in patients with acute gastrointestinal bleeding (HALT-IT): an international randomised, double-blind, placebo-controlled trial
Background: Tranexamic acid reduces surgical bleeding and reduces death due to bleeding in patients with trauma.
Meta-analyses of small trials show that tranexamic acid might decrease deaths from gastrointestinal bleeding. We
aimed to assess the effects of tranexamic acid in patients with gastrointestinal bleeding.
Methods: We did an international, multicentre, randomised, placebo-controlled trial in 164 hospitals in 15 countries.
Patients were enrolled if the responsible clinician was uncertain whether to use tranexamic acid, were aged above the
minimum age considered an adult in their country (either aged 16 years and older or aged 18 years and older), and
had significant (defined as at risk of bleeding to death) upper or lower gastrointestinal bleeding. Patients were
randomly assigned by selection of a numbered treatment pack from a box containing eight packs that were identical
apart from the pack number. Patients received either a loading dose of 1 g tranexamic acid, which was added to
100 mL infusion bag of 0·9% sodium chloride and infused by slow intravenous injection over 10 min, followed by a
maintenance dose of 3 g tranexamic acid added to 1 L of any isotonic intravenous solution and infused at 125 mg/h
for 24 h, or placebo (sodium chloride 0·9%). Patients, caregivers, and those assessing outcomes were masked to
allocation. The primary outcome was death due to bleeding within 5 days of randomisation; analysis excluded patients
who received neither dose of the allocated treatment and those for whom outcome data on death were unavailable.
This trial was registered with Current Controlled Trials, ISRCTN11225767, and ClinicalTrials.gov, NCT01658124.
Findings: Between July 4, 2013, and June 21, 2019, we randomly allocated 12 009 patients to receive tranexamic acid
(5994, 49·9%) or matching placebo (6015, 50·1%), of whom 11 952 (99·5%) received the first dose of the allocated
treatment. Death due to bleeding within 5 days of randomisation occurred in 222 (4%) of 5956 patients in the
tranexamic acid group and in 226 (4%) of 5981 patients in the placebo group (risk ratio [RR] 0·99, 95% CI 0·82–1·18).
Arterial thromboembolic events (myocardial infarction or stroke) were similar in the tranexamic acid group and
placebo group (42 [0·7%] of 5952 vs 46 [0·8%] of 5977; 0·92; 0·60 to 1·39). Venous thromboembolic events (deep vein
thrombosis or pulmonary embolism) were higher in tranexamic acid group than in the placebo group (48 [0·8%] of
5952 vs 26 [0·4%] of 5977; RR 1·85; 95% CI 1·15 to 2·98).
Interpretation: We found that tranexamic acid did not reduce death from gastrointestinal bleeding. On the basis of our
results, tranexamic acid should not be used for the treatment of gastrointestinal bleeding outside the context of a
randomised trial
Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures
Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo
Correction to: Abstracts from the NIHR INVOLVE Conference 2017
[This corrects the article DOI: 10.1186/s40900-017-0075-x.]
4MOST-4-metre Multi-Object Spectroscopic Telescope
4MOST is a wide-field, high-multiplex spectroscopic survey facility under development for the VISTA telescope of the European Southern Observatory (ESO). Its main science drivers are in the fields of galactic archeology, high-energy physics, galaxy evolution and cosmology. 4MOST will in particular provide the spectroscopic complements to the large area surveys coming from space missions like Gaia, eROSITA, Euclid, and PLATO and from ground-based facilities like VISTA, VST, DES, LSST and SKA. The 4MOST baseline concept features a 2.5 degree diameter field-of-view with similar to 2400 fibres in the focal surface that are configured by a fibre positioner based on the tilting spine principle. The fibres feed two types of spectrographs; similar to 1600 fibres go to two spectrographs with resolution R> 5000 (lambda similar to 390-930 nm) and similar to 800 fibres to a spectrograph with R> 18,000 (lambda similar to 392-437 nm & 515-572 nm & 605-675 nm). Both types of spectrographs are fixed-configuration, three-channel spectrographs. 4MOST will have an unique operations concept in which 5 year public surveys from both the consortium and the ESO community will be combined and observed in parallel during each exposure, resulting in more than 25 million spectra of targets spread over a large fraction of the southern sky. The 4MOST Facility Simulator (4FS) was developed to demonstrate the feasibility of this observing concept. 4MOST has been accepted for implementation by ESO with operations expected to start by the end of 2020. This paper provides a top-level overview of the 4MOST facility, while other papers in these proceedings provide more detailed descriptions of the instrument concept[1], the instrument requirements development[2], the systems engineering implementation[3], the instrument model[4], the fibre positioner concepts[5], the fibre feed[6], and the spectrographs[7]
Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial
Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between Mar