1,084 research outputs found

    Optical spectroscopic investigation of m-plane GaN thin films

    Get PDF
    [[abstract]]M-plane GaN thin films grown on Îł-LiAlO2 substrate were investigated at different temperatures by photoluminescence (PL) and time-resolved photoluminescence (TRPL) spectroscopy. The origin of two distinct emissions, P1 and P2 observed in the PL spectra were established by analyzing their PL and TRPL properties at different temperatures. The P1 emission is attributed to the excitons bound to the stacking faults (SFs). The P2 shows an anomalous “S-shaped” emission shift with increasing temperature (T), and the associated mechanism is discussed. The radiative life time ‘τr’ for P2 emission exhibits the T 3/2 dependence at higher temperatures and deviates at lower temperatures whereas the radiative life time ‘τr’ for P1 emission does not show the T 3/2 dependence with temperature. The polarization-dependent PL study reveals that P2 emission involves free holes in the transition at room temperature.[[notice]]èŁœæ­ŁćźŒç•ą[[incitationindex]]SCI[[booktype]]電歐

    Growth and Characteristics of High-quality InN by Plasma- Assisted Molecular Beam Epitaxy

    Get PDF
    The high-quality InN epifilms and InN microdisks have been grown with InGaN buffer layers at low temperatures by plasma-assisted molecular beam epitaxy. The samples were analyzed using X-ray diffraction, scanning electron microscopy, high-resolution transmission electron microscopy, and photoluminescence. The characteristics of the InN epifilms and InN microdisks were studied, and the role of InGaN buffer was evaluated

    Need for a safe vaccine against respiratory syncytial virus infection

    Get PDF
    Human respiratory syncytial virus (HRSV) is a major cause of severe respiratory tract illnesses in infants and young children worldwide. Despite its importance as a respiratory pathogen, there is currently no licensed vaccine for HRSV. Following failure of the initial trial of formalin-inactivated virus particle vaccine, continuous efforts have been made for the development of safe and efficacious vaccines against HRSV. However, several obstacles persist that delay the development of HRSV vaccine, such as the immature immune system of newborn infants and the possible Th2-biased immune responses leading to subsequent vaccine-enhanced diseases. Many HRSV vaccine strategies are currently being developed and evaluated, including live-attenuated viruses, subunit-based, and vector-based candidates. In this review, the current HRSV vaccines are overviewed and the safety issues regarding asthma and vaccine-induced pathology are discussed

    Acute kidney disease and renal recovery : consensus report of the Acute Disease Quality Initiative (ADQI) 16 Workgroup

    Get PDF
    Consensus definitions have been reached for both acute kidney injury (AKI) and chronic kidney disease (CKD) and these definitions are now routinely used in research and clinical practice. The KDIGO guideline defines AKI as an abrupt decrease in kidney function occurring over 7 days or less, whereas CKD is defined by the persistence of kidney disease for a period of > 90 days. AKI and CKD are increasingly recognized as related entities and in some instances probably represent a continuum of the disease process. For patients in whom pathophysiologic processes are ongoing, the term acute kidney disease (AKD) has been proposed to define the course of disease after AKI; however, definitions of AKD and strategies for the management of patients with AKD are not currently available. In this consensus statement, the Acute Disease Quality Initiative (ADQI) proposes definitions, staging criteria for AKD, and strategies for the management of affected patients. We also make recommendations for areas of future research, which aim to improve understanding of the underlying processes and improve outcomes for patients with AKD

    Top Quark Mass Measurement from Dilepton Events at CDF II with the Matrix-Element Method

    Get PDF
    We describe a measurement of the top quark mass using events with two charged leptons collected by the CDF II detector from ppˉp\bar{p} collisions with s=1.96\sqrt s = 1.96 TeV at the Fermilab Tevatron. The likelihood in top mass is calculated for each event by convoluting the leading order matrix element describing qqˉ→ttˉ→bℓΜℓbˉℓâ€ČΜℓâ€Čq\bar{q} \to t\bar{t} \to b\ell\nu_{\ell}\bar{b}\ell'\nu_{\ell'} with detector resolution functions. The presence of background events in the data sample is modeled using similar calculations involving the matrix elements for major background processes. In a data sample with integrated luminosity of 340 pb−1^{-1}, we observe 33 candidate events and measure Mtop=165.2±6.1(stat.)±3.4(syst.) GeV/c2.M_{top} = 165.2 \pm 6.1(\textrm{stat.}) \pm 3.4(\textrm{syst.}) \mathrm{~GeV}/c^2. This measurement represents the first application of this method to events with two charged leptons and is the most precise single measurement of the top quark mass in this channel.Comment: 21 pages, 14 figure

    Search for New Physics in Lepton + Photon + X Events with L=305 pb-1 of ppbar Collisions at roots=1.96 TeV

    Get PDF
    We present results of a search for anomalous production of events containing a charged lepton (either electron or muon) and a photon, both with high transverse momentum, accompanied by additional signatures, X, including missing transverse energy (MET) and additional leptons and photons. We use the same kinematic selection criteria as in a previous CDF search, but with a substantially larger data set, 305 pb-1, a ppbar collision energy of 1.96 TeV, and the upgraded CDF II detector. We find 42 Lepton+Photon+MET events versus a standard model expectation of 37.3 +- 5.4 events. The level of excess observed in Run I, 16 events with an expectation of 7.6 +- 0.7 events (corresponding to a 2.7 sigma effect), is not supported by the new data. In the signature of Multi-Lepton+Photon+X we observe 31 events versus an expectation of 23.0 +- 2.7 events. In this sample we find no events with an extra photon or MET and so find no events like the one ee+gg+MET event observed in Run I.Comment: 7 pages, 3 figures, 1 table. Accepted to PR

    Measurement of the Dipion Mass Spectrum in X(3872) -> J/Psi Pi+ Pi- Decays

    Get PDF
    We measure the dipion mass spectrum in X(3872)--> J/Psi Pi+ Pi- decays using 360 pb-1 of pbar-p collisions at 1.96 TeV collected with the CDF II detector. The spectrum is fit with predictions for odd C-parity (3S1, 1P1, and 3DJ) charmonia decaying to J/Psi Pi+ Pi-, as well as even C-parity states in which the pions are from Rho0 decay. The latter case also encompasses exotic interpretations, such as a D0-D*0Bar molecule. Only the 3S1 and J/Psi Rho hypotheses are compatible with our data. Since 3S1 is untenable on other grounds, decay via J/Psi Rho is favored, which implies C=+1 for the X(3872). Models for different J/Psi-Rho angular momenta L are considered. Flexibility in the models, especially the introduction of Rho-Omega interference, enable good descriptions of our data for both L=0 and 1.Comment: 7 pages, 4 figures -- Submitted to Phys. Rev. Let

    Measurement of the Ratio of Branching Fractions B(D0 -> K+ pi-)/B(D0 -> K- pi+) using the CDF II Detector

    Get PDF
    We present a measurement of R_B, the ratio of the branching fraction for the rare decay D0 -> K+ pi- to that for the Cabibbo-favored decay D0 -> K- pi+. Charge conjugate decays are implicitly included. A signal of 2005 +/- 104 events for the decay D0 -> K+ pi- is obtained using the CDF II detector at the Fermilab Tevatron collider. The data set corresponds to an integrated luminosity of 0.35 1/fb produced in p-bar/p collisions at sqrt{s}=1.96 TeV. Assuming no mixing, we find R_B = [ 4.05 +/- 0.21 (stat) +/- 0.11 (syst) ] x 10(-3). This measurement is consistent with the world average, and comparable in accuracy with the best measurements from other experiments.Comment: 7 pages, 3 figure
    • 

    corecore