422 research outputs found

    Paediatric Bronchology

    Get PDF

    Incidence of complications in bronchoscopy. Multicentre prospective study of 20,986 bronchoscopies.

    Get PDF
    Aim. To evaluate the frequency of complications in bronchoscopy from data compiled between 1/2/2002 to 1/2/2003. Materials and methods. Nineteen Italian centres of thoracic endoscopy participated in the study, for a total of 20,986 bronchoscopies (FBS), including 10,658 explorative bronchoscopies (EB) (50.79%), 5,520 bronchial biopsies (BB) (26.30%), 1,660 transbronchial biopsies (TBB) (7.91%), 1,127 broncho-alveolar lavages (BAL) (5.37%), 930 transbronchial needle-aspirates (TBNA) (4.43%), 1.091 therapeutic bronchoscopies (TB), comprising NDYAG Laser, argon-plasma, electrocautery knife, stent insertion (5.20%). 82.4% of the procedures involved the use of a flexible bronchoscope, 16.3% were carried out using a rigid bronchoscope and 1.3% using the mixed technique. Results. The total number of complications recorded was 227 (1.08% of the cases examined), including 20 (0.09%) during local anesthesia and pre-medication, 195 (0.92%) during the endoscopic procedures and 12 (0.05%) in the two hours following FBS. The total number of deaths was 4 (0.02%), due to cardiac arrest, pulmonary edema, delayed respiratory failure and shock in pre-medication, respectively. 68.28% of the complications were treated medically, 25.99% by means of endoscopy and 5.72% with surgery. The healing percentage was 98.2%. Conclusions. This study has shown that bronchoscopy is a safe method with low incidence of mortality and complications. The preparation, experience and continuous training of the operators of the medical and nursing team seem to play a fundamental role in reducing the incidence of complications at least in certain procedures such as BB and TBB

    How much does size really matter? Exploring the limits of graphene as Li ion battery anode material

    Get PDF
    Abstract We unravel the role of flake dimensionality on the lithiation/de-lithiation processes and electrochemical performance of anodes based on few-(FLG) and multi-layer graphene (MLG) flakes prepared by liquid phase exfoliation (LPE) of pristine graphite. The flakes are sorted by lateral size (from 380 to 75 nm) and thickness from 20 (MLG) to 2 nm (FLG) exploiting a sedimentation-based separation in centrifugal field and, finally, deposited onto Cu disks for the realization of four binder-free anodes. The electrochemical results show that decreasing lateral size and thickness leads to an increase of the initial specific capacity from ≈590 to ≈1270mAhg −1 . However, an increasing irreversible capacity is also associated to the reduction of flakes' size. We find, in addition, that the preferential Li ions storage by adsorption rather than intercalation in small lateral size

    Beyond Metformin: Safety Considerations in the Decision-Making Process for Selecting a Second Medication for Type 2 Diabetes Management: Reflections From aDiabetes CareEditors’ Expert Forum

    Get PDF
    The trend toward personalized management of diabetes has focused attention on the differences among available pharmacological agents in terms of mechanisms of action, efficacy, and, most important, safety. Clinicians must select from these features to develop individualized therapy regimens. In June 2013, a nine-member Diabetes Care Editors’ Expert Forum convened to review safety evidence for six major diabetes drug classes: insulin, sulfonylureas (SUs), thiazolidinediones (TZDs), glucagon-like peptide-1 receptor agonists, dipeptidyl peptidase-4 inhibitors, and sodium glucose cotransporter 2 inhibitors. This article, an outgrowth of the forum, summarizes well-delineated and theoretical safety concerns related to these drug classes, as well as the panelists’ opinions regarding their best use in patients with type 2 diabetes. All of the options appear to have reasonably wide safety margins when used appropriately. Those about which we know the most—metformin, SUs, insulin, and perhaps now also TZDs—are efficacious in most patients and can be placed into a basic initial algorithm. However, these agents leave some clinical needs unmet. Selecting next steps is a more formidable process involving newer agents that are understood less well and for which there are unresolved questions regarding risk versus benefit in certain populations. Choosing a specific agent is not as important as implementing some form of early intervention and advancing rapidly to some form of combination therapy as needed. When all options are relatively safe given the benefits they confer, therapeutic decision making must rely on a personalized approach, taking into account patients’ clinical circumstances, phenotype, pathophysiological defects, preferences, abilities, and costs

    DEFLAZACORT VERSUS PREDNISONE/PREDNISOLONE FOR MAINTAINING MOTOR FUNCTION AND DELAYING LOSS OF AMBULATION: A POST HOC ANALYSIS FROM THE ACT DMD TRIAL

    Get PDF
    Introduction: ACT DMD was a 48-week trial of ataluren for nonsense mutation Duchenne muscular dystrophy (nmDMD). Patients received corticosteroids for ≄6 months at entry and stable regimens throughout study. This post hoc analysis compares efficacy and safety for deflazacort and prednisone/prednisolone in the placebo arm. Methods: Patients received deflazacort (n = 53) or prednisone/prednisolone (n = 61). Endpoints included change from baseline in 6-minutewalk distance (6MWD), timed function tests, estimated age at loss of ambulation (extrapolated from 6MWD). Results: Mean changes in 6MWD were -39.0 m (deflazacort; 95%confidence limit [CL], -68.85, -9.17) and -70.6 m (prednisone/prednisolone; 95% CL, -97.16, -44.02).Mean changes in 4-stair climb were 3.79 s (deflazacort; 95% CL, 1.54, 6.03) and 6.67 s (prednisone/prednisolone; 95% CL, 4.69, 8.64). Conclusions: This analysis, limited by its post hoc nature, suggests greater preservation of 6MWD and 4-stair climb with deflazacort vs. prednisone/prednisolone. A head-to-head comparisonwill better define these differences

    Efficacy and safety of alirocumab in insulin-treated patients with type 1 or type 2 diabetes and high cardiovascular risk:Rationale and design of the ODYSSEY DM-INSULIN trial

    Get PDF
    Aims: The coadministration of alirocumab, a PCSK9 inhibitor for treatment of hypercholesterolaemia, and insulin in diabetes mellitus (DM) requires further study. Described here is the rationale behind a phase-IIIb study designed to characterize the efficacy and safety of alirocumab in insulin-treated patients with type 1 (T1) or type 2 (T2) DM with hypercholesterolaemia and high cardiovascular (CV) risk. Methods: ODYSSEY DM-INSULIN (NCT02585778) is a randomized, double-blind, placebo-controlled, multicentre study that planned to enrol around 400 T2 and up to 100 T1 insulin-treated DM patients. Participants had low-density lipoprotein cholesterol (LDL-C) levels at screening. ≄. 70. mg/dL (1.81. mmol/L) with stable maximum tolerated statin therapy or were statin-intolerant, and taking (or not) other lipid-lowering therapy; they also had established CV disease or at least one additional CV risk factor. Eligible patients were randomized 2:1 to 24. weeks of alirocumab 75. mg every 2. weeks (Q2W) or a placebo. Alirocumab-treated patients with LDL-C. ≄. 70. mg/dL at week 8 underwent a blinded dose increase to 150. mg Q2W at week 12. Primary endpoints were the difference between treatment arms in percentage change of calculated LDL-C from baseline to week 24, and alirocumab safety. Results: This is an ongoing clinical trial, with 76 T1 and 441 T2 DM patients enrolled; results are expected in mid-2017. Conclusion: The ODYSSEY DM-INSULIN study will provide information on the efficacy and safety of alirocumab in insulin-treated individuals with T1 or T2 DM who are at high CV risk and have hypercholesterolaemia not adequately controlled by the maximum tolerated statin therapy

    Scientific Objectives of Einstein Telescope

    Full text link
    The advanced interferometer network will herald a new era in observational astronomy. There is a very strong science case to go beyond the advanced detector network and build detectors that operate in a frequency range from 1 Hz-10 kHz, with sensitivity a factor ten better in amplitude. Such detectors will be able to probe a range of topics in nuclear physics, astronomy, cosmology and fundamental physics, providing insights into many unsolved problems in these areas.Comment: 18 pages, 4 figures, Plenary talk given at Amaldi Meeting, July 201

    Calibration and sensitivity of the Virgo detector during its second science run

    Full text link
    The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.Comment: 30 pages, 23 figures, 1 table. Published in Classical and Quantum Gravity (CQG), Corrigendum include
    • 

    corecore