40 research outputs found
Gas gain on single wire chambers filled with pure isobutane at low pressure
The gas gain of single-wire chambers filled with isobutane, with cell
cross-section 12x12 mm and wire diameters of 15, 25, 50 and 100 m, has
been measured at pressures ranging 12-92 Torr. Contrary to the experience at
atmospheric pressure, at very low pressures the gas gain on thick wires is
higher than that on thin wires at the same applied high voltage as was recently
shown. Bigger wire diameters should be used in wire chambers operating at very
low pressure if multiple scattering on wires is not an issue.Comment: 9 pages, 6 figure
Study of a self quenching streamer mode in pure gases of DME and isobutane
A self quenching streamer (SQS), or limited streamer mode has been studied in
single wire chambers with cross-sections 12x12 mm and wire diameters 15, 25 and
50 microns. Chambers were filled with either pure dimethyl ether (DME) or
isobutane gases and irradiated with Gd-148 alpha and Fe-55 x-ray sources. Clear
transitions from a proportional to 100% SQS mode were observed on all three
diameter wires with both gases irradiated with alpha particles. Double SQS
discharges due to inclined tracks observed in DME gas allowed an estimation of
a streamer size along the wire of less than 1 mm. The second SQS discharge
appears less than 1 mm from the first within about 500 ns. Charge spectra
obtained with DME irradiated with Fe-55 x-rays might also be interpreted as a
transition to a SQS mode, although no direct evidence of that was seen in the
observed pulse shapes
Precision planar drift chambers and cradle for the TWIST muon decay spectrometer
To measure the muon decay parameters with high accuracy, we require an array
of precision drift detector layers whose relative position is known with very
high accuracy. This article describes the design, construction and performance
of these detectors in the TWIST (TRIUMF Weak Interaction Symmetry Test)
spectrometer.Comment: 44 pages, 16 Postscript figures, LaTeX2e, uses Elsevier class
elsart.cls, package graphicx, submitted to Nuclear Instruments & Methods in
Physics Researc
Study of doubly strange systems using stored antiprotons
Bound nuclear systems with two units of strangeness are still poorly known despite their importance for many strong interaction phenomena. Stored antiprotons beams in the GeV range represent an unparalleled factory for various hyperon-antihyperon pairs. Their outstanding large production probability in antiproton collisions will open the floodgates for a series of new studies of systems which contain two or even more units of strangeness at the P‾ANDA experiment at FAIR. For the first time, high resolution γ-spectroscopy of doubly strange ΛΛ-hypernuclei will be performed, thus complementing measurements of ground state decays of ΛΛ-hypernuclei at J-PARC or possible decays of particle unstable hypernuclei in heavy ion reactions. High resolution spectroscopy of multistrange Ξ−-atoms will be feasible and even the production of Ω−-atoms will be within reach. The latter might open the door to the |S|=3 world in strangeness nuclear physics, by the study of the hadronic Ω−-nucleus interaction. For the first time it will be possible to study the behavior of Ξ‾+ in nuclear systems under well controlled conditions
Scintillator ageing of the T2K near detectors from 2010 to 2021
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation