198 research outputs found

    High Resolution Electron Beam Induced Current Measurements in an Scanning Tunneling Microscope on GaAs-MESFET

    Get PDF
    Recently, the first results of electron beam induced current (EBIC) measurements in a scanning tunneling microscope (STM) have been reported. Although the acquired results match with those obtained in conventional EBIC investigations, the interpretation of the obtained results is still restricted solely to a qualitative discussion. In this paper, a quantitative approach is used for two-dimensional numerical simulations of induced currents in GaAs-MESFET leading to a first starting point for a sophisticated interpretation of the dependence of induced currents on experimental and device parameters

    Development of an Scanning Tunneling Microscopy-Based Electron Beam Induced Current (EBIC) Microscope

    Get PDF
    Measurements of electron beam induced currents (EBIC) can either be performed in a scanning electron microscope (SEM) or in a scanning tunneling microscope (STM), since both microscopes are very similar in their basic assembly. However, a straightforward application of an STM in EBIC-measurements, i.e. the use of a microscope tip as a fine source for low energetic electrons is not possible due to the specific demands on the instrument in an EBIC application. The present paper gives a compilation of these demands and describes their conversion into an optimized STM-EBIC microscope

    Absolute dimensions of eclipsing binaries. XXVIII. BK Pegasi and other F-type binaries: Prospects for calibration of convective core overshoot

    Full text link
    We present a detailed study of the F-type detached eclipsing binary BK Peg, based on new photometric and spectroscopic observations. The two components, which have evolved to the upper half of the main-sequence band, are quite different with masses and radii of (1.414 +/- 0.007 Msun, 1.988 +/- 0.008 Rsun) and (1.257 +/- 0.005 Msun, 1.474 +/- 0.017 Rsun), respectively. The 5.49 day period orbit of BK Peg is slightly eccentric (e = 0.053). The measured rotational velocities are 16.6 +/- 0.2 (primary) and 13.4 +/- 0.2 (secondary) km/s. For the secondary component this corresponds to (pseudo)synchronous rotation, whereas the primary component seems to rotate at a slightly lower rate. We derive an iron abundance of [Fe/H] =-0.12 +/- 0.07 and similar abundances for Si, Ca, Sc, Ti, Cr and Ni. Yonsei-Yale and Victoria-Regina evolutionary models for the observed metal abundance reproduce BK Peg at ages of 2.75 and 2.50 Gyr, respectively, but tend to predict a lower age for the more massive primary component than for the secondary. We find the same age trend for three other upper main-sequence systems in a sample of well studied eclipsing binaries with components in the 1.15-1.70 Msun range, where convective core overshoot is gradually ramped up in the models. We also find that the Yonsei-Yale models systematically predict higher ages than the Victoria-Regina models. The sample includes BW Aqr, and as a supplement we have determined a [Fe/H] abundance of -0.07 +/- 0.11 for this late F-type binary. We propose to use BK Peg, BW Aqr, and other well-studied 1.15-1.70 Msun eclipsing binaries to fine-tune convective core overshoot, diffusion, and possibly other ingredients of modern theoretical evolutionary models.Comment: Accepted for publication in Astronomy and Astrophysic

    Electrical Quality Assurance of the Superconducting Circuits during LHC Machine Assembly

    Get PDF
    Based on the LHC powering reference database, all-together 1750 superconducting circuits were connected in the various cryogenic transfer lines of the LHC machine. Testing the continuity, magnet polarity, and the quality of the electrical insulation were the main tasks of the Electrical Quality Assurance (ELQA) activities during the LHC machine assembly. With the assembly of the LHC now complete, the paper reviews the work flow, resources, and the qualification results including the different types of electrical non-conformities

    Four-colour photometry of eclipsing binaries. XLI uvby light curves for AD Bootis, HW Canis Majoris, SW Canis Majoris, V636 Centauri, VZ Hydrae, and WZ Ophiuchi

    Full text link
    CONTEXT: Accurate mass, radius, and abundance determinations from binaries provide important information on stellar evolution, fundamental to central fields in modern astrophysics and cosmology. AIMS: Within the long-term Copenhagen Binary Project, we aim to obtain high-quality light curves and standard photometry for double-lined detached eclipsing binaries with late A, F, and G type main-sequence components, needed for the determination of accurate absolute dimensions and abundances, and for detailed comparisons with results from recent stellar evolutionary models. METHODS: Between March 1985 and July 2007, we carried out photometric observations of AD Boo, HW CMA, SW CMa, V636 Cen, VZ Hya, and WZ Oph at the Str"omgren Automatic Telescope at ESO, La Silla. RESULTS: We obtained complete uvby light curves, ephemerides, and standard uvby\beta indices for all six systems.For V636 Cen and HW CMa, we present the first modern light curves, whereas for AD Boo, SW CMa, VZ Hya, and WZ Oph, they are both more accurate and more complete than earlier data. Due to a high orbital eccentricity (e = 0.50), combined with a low orbital inclination (i = 84.7), only one eclipse, close to periastron, occurs for HW CMa. For the two other eccentric systems, V636 Cen (e = 0.134) and SW CMa (e = 0.316), apsidal motion has been detected with periods of 5270 +/- 335 and 14900 +/- 3600 years, respectively.Comment: Only change is: Bottom lines (hopefully) not truncated anymore. Accepted for publication in Astonomy & Astrophysic

    Synoptic tool for reporting of hematological and lymphoid neoplasms based on World Health Organization classification and College of American Pathologists checklist

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Synoptic reporting, either as part of the pathology report or replacing some free text component incorporates standardized data elements in the form of checklists for pathology reporting. This ensures the pathologists make note of these findings in their reports, thereby improving the quality and uniformity of information in the pathology reports.</p> <p>Methods</p> <p>The purpose of this project is to develop the entire set of elements in the synoptic templates or "worksheets" for hematologic and lymphoid neoplasms using the World Health Organization (WHO) Classification and the College of American Pathologists (CAP) Cancer Checklists. The CAP checklists' content was supplemented with the most updated classification scheme (WHO classification), specimen details, staging as well as information on various ancillary techniques such as cytochemical studies, immunophenotyping, cytogenetics including Fluorescent In-situ Hybridization (FISH) studies and genotyping. We have used a digital synoptic reporting system as part of an existing laboratory information system (LIS), CoPathPlus, from Cerner DHT, Inc. The synoptic elements are presented as discrete data points, so that a data element such as tumor type is assigned from the synoptic value dictionary under the value of tumor type, allowing the user to search for just those cases that have that value point populated.</p> <p>Results</p> <p>These synoptic worksheets are implemented for use in our LIS. The data is stored as discrete data elements appear as an accession summary within the final pathology report. In addition, the synoptic data can be exported to research databases for linking pathological details on banked tissues.</p> <p>Conclusion</p> <p>Synoptic reporting provides a structured method for entering the diagnostic as well as prognostic information for a particular pathology specimen or sample, thereby reducing transcription services and reducing specimen turnaround time. Furthermore, it provides accurate and consistent diagnostic information dictated by pathologists as a basis for appropriate therapeutic modalities. Using synoptic reports, consistent data elements with minimized typographical and transcription errors can be generated and placed in the LIS relational database, enabling quicker access to desired information and improved communication for appropriate cancer management. The templates will also eventually serve as a conduit for capturing and storing data in the virtual biorepository for translational research. Such uniformity of data lends itself to subsequent ease of data viewing and extraction, as demonstrated by rapid production of standardized, high-quality data from the hemopoietic and lymphoid neoplasm specimens.</p

    Phase II study of capecitabine and oxaliplatin given prior to and concurrently with preoperative pelvic radiotherapy in patients with locally advanced rectal cancer

    Get PDF
    This multicentre phase II study evaluated the efficacy and safety of preoperative capecitabine plus oxaliplatin and radiotherapy (RT) in patients with locally advanced rectal cancer (T3/T4 rectal adenocarcinoma with or without nodal involvement). Treatment consisted of one cycle of XELOX (capecitabine 1000 mg m−2 bid on days 1–14 and oxaliplatin 130 mg m−2 on day 1), followed by RT (1.8 Gy fractions 5 days per week for 5 weeks) plus CAPOX (capecitabine 825 mg m−2 bid on days 22–35 and 43–56, and oxaliplatin 50 mg m−2 on days 22, 29, 43 and 50). Surgery was recommended 5 weeks after completion of chemoradiotherapy. The primary end point was pathological complete tumour response (pCR). Sixty patients were enrolled. In the intent-to-treat population, the pCR rate was 23% (95% CI: 13–36%). 58 patients underwent surgery; R0 resection was achieved in 57 (98%) patients, including all 5 patients with T4 tumours. Sphincter preservation was achieved in 49 (84%) patients. Tumour and/or nodal downstaging was observed in 39 (65%) patients. The most common grade 3/4 adverse events were diarrhoea (20%) and lymphocytopaenia (43%). Preoperative capecitabine, oxaliplatin and RT achieved encouraging rates of pCR, R0 resection, sphincter preservation and tumour downstaging in patients with locally advanced rectal cancer

    Value of ADC measurements for nodal staging after chemoradiation in locally advanced rectal cancer—a per lesion validation study

    Get PDF
    OBJECTIVES: To evaluate the performance of diffusion-weighted MRI (DWI) in addition to T2-weighted (T2W) MRI for nodal restaging after chemoradiation in rectal cancer. METHODS: Thirty patients underwent chemoradiation followed by MRI (1.5 T) and surgery. Imaging consisted of T2W-MRI and DWI (b0, 500, 1000). On T2W-MRI, nodes were scored as benign/malignant by two independent readers (R1, R2). Mean apparent diffusion coefficient (ADC) was measured for each node. Diagnostic performance was compared for T2W-MRI, ADC and T2W+ADC, using a per lesion histological validation. RESULTS: ADC was higher for the malignant nodes (1.43 +/- 0.38 vs 1.19 +/- 0.27 *10(-3) mm(2)/s, p < 0.001). Area under the ROC curve/sensitivity/specificity were 0.88/65%/93% (R1) and 0.95/71%/91% (R2) using T2W-MRI; 0.66/53%/82% using ADC (mean of two readers); and 0.91/56%/98% (R1) and 0.96/56%/99% (R2) using T2W+ADC. There was no significant difference between T2W-MRI and T2W+ADC. Interobserver reproducibility was good for T2W-MRI (kappa0.73) and ADC (intraclass correlation coefficient 0.77). CONCLUSIONS: After chemoradiation, ADC measurements may have potential for nodal characterisation, but DWI on its own is not reliable. Addition of DWI to T2W-MRI does not improve accuracy and T2W-MRI is already sufficiently accurate
    corecore