96 research outputs found
Initial results of combined anterior mitral leaflet extension and myectomy in patients with obstructive hypertrophic cardiomyopathy
Objectives. The purpose of this study was to describe the clinical and functional results of combined anterior mitral leaflet extension and myectomy in patients with hypertrophic obstructive cardiomyopathy. Background. Septal myectomy is the most commonly performed surgical procedure in patients with hypertrophic cardiomyopathy and left ventricular outflow tract obstruction. Because of the role of the mitral valve in creating the outflow tract gradient, mitral valve replacement or plication is performed in selected cases in combination with myectomy, often with better hemodynamic results than those of myectomy alone. Mitral valve leaflet extension, in which a glutaraldehyde-preserved autologous pericardial patch is used to enlarge the mitral valve along its horizontal axis, is a novel surgical approach in patients with hypertrophic obstructive cardiomyopathy. Methods. Eight patients with hypertrophic obstructive cardiomyopathy were treated with mitral leaflet extension and myectomy. Preoperative and postoperative data (New York Heart Association functional class, number of drugs prescribed, width of the interventricular septum, severity of mitral valve regurgitation, severity of systolic anterior motion of the mitral valve and outflow tract gradient) were compared with those of 12 patients undergoing myectomy alone. Results. Preoperative evaluation demonstrated that mitral regurgitation and systolic anterior motion of the mitral valve were more severe in the group undergoing mitral valve extension (p < 0.001 and p < 0.05, respectively). There were no deaths associated with either surgical procedure. Two patients, both treated by myectomy alone, died during the follow-up period. Postoperatively, patients treated with mitral valve extension had less mitral regurgitation (p < 0.005), less residual systolic anterior motion (p < 0.01), greater improvement in functional class (p = 0.05) and greater reduction in the number of drugs (p < 0.005) and in septal thickness (p < 0.05). Conclusions. Mitral leaflet extension in combination with myectomy is a promising new surgical approach that may provide superior results to those of myectomy alone. Further studies are needed to determine the clinical value of this procedure
Modeling accuracy as a function of response time with the generalised linear mixed effects model
In psycholinguistic studies using error rates as a response measure, response times (RT) are most often analyzed independently of the error rate, although it is widely recognized that they are related. In this paper we present a mixed effects logistic regression model for the error rate that uses RT as a trial-level fixed- and random-effect regression input. Production data from a translationârecall experiment are analyzed as an example. Several model comparisons reveal that RT improves the fit of the regression model for the error rate. Two simulation studies then show how the mixed effects regression model can identify individual participants for whom (a) faster responses are more accurate, (b) faster responses are less accurate, or (c) there is no relation between speed and accuracy. These results show that this type of model can serve as a useful adjunct to traditional techniques, allowing psycholinguistic researchers to examine more closely the relationship between RT and accuracy in individual subjects and better account for the variability which may be present, as well as a preliminary step to more advanced RTâaccuracy modeling
Electron-induced neutron knockout from He
The differential cross section for electron-induced neutron knockout in the reaction 4He(e,eâČn)3He has been measured for the first time with a statistical accuracy of 11%. The experiment was performed in quasielastic kinematics at a momentum transfer of 300ââMeV/c and in the missing-momentum range of 25â70ââMeV/c. The comparison of the data with theoretical calculations shows an impressive increase of the cross section resulting from final state interaction effects. Specifically , the pân charge-exchange process dominates the cross section in this kinematical regime. (APS
Detecting a stochastic gravitational wave background with the Laser Interferometer Space Antenna
The random superposition of many weak sources will produce a stochastic
background of gravitational waves that may dominate the response of the LISA
(Laser Interferometer Space Antenna) gravitational wave observatory. Unless
something can be done to distinguish between a stochastic background and
detector noise, the two will combine to form an effective noise floor for the
detector. Two methods have been proposed to solve this problem. The first is to
cross-correlate the output of two independent interferometers. The second is an
ingenious scheme for monitoring the instrument noise by operating LISA as a
Sagnac interferometer. Here we derive the optimal orbital alignment for
cross-correlating a pair of LISA detectors, and provide the first analytic
derivation of the Sagnac sensitivity curve.Comment: 9 pages, 11 figures. Significant changes to the noise estimate
Muon Track Reconstruction and Data Selection Techniques in AMANDA
The Antarctic Muon And Neutrino Detector Array (AMANDA) is a high-energy
neutrino telescope operating at the geographic South Pole. It is a lattice of
photo-multiplier tubes buried deep in the polar ice between 1500m and 2000m.
The primary goal of this detector is to discover astrophysical sources of high
energy neutrinos. A high-energy muon neutrino coming through the earth from the
Northern Hemisphere can be identified by the secondary muon moving upward
through the detector. The muon tracks are reconstructed with a maximum
likelihood method. It models the arrival times and amplitudes of Cherenkov
photons registered by the photo-multipliers. This paper describes the different
methods of reconstruction, which have been successfully implemented within
AMANDA. Strategies for optimizing the reconstruction performance and rejecting
background are presented. For a typical analysis procedure the direction of
tracks are reconstructed with about 2 degree accuracy.Comment: 40 pages, 16 Postscript figures, uses elsart.st
Sensitivity of the IceCube Detector to Astrophysical Sources of High Energy Muon Neutrinos
We present the results of a Monte-Carlo study of the sensitivity of the
planned IceCube detector to predicted fluxes of muon neutrinos at TeV to PeV
energies. A complete simulation of the detector and data analysis is used to
study the detector's capability to search for muon neutrinos from sources such
as active galaxies and gamma-ray bursts. We study the effective area and the
angular resolution of the detector as a function of muon energy and angle of
incidence. We present detailed calculations of the sensitivity of the detector
to both diffuse and pointlike neutrino emissions, including an assessment of
the sensitivity to neutrinos detected in coincidence with gamma-ray burst
observations. After three years of datataking, IceCube will have been able to
detect a point source flux of E^2*dN/dE = 7*10^-9 cm^-2s^-1GeV at a 5-sigma
significance, or, in the absence of a signal, place a 90% c.l. limit at a level
E^2*dN/dE = 2*10^-9 cm^-2s^-1GeV. A diffuse E-2 flux would be detectable at a
minimum strength of E^2*dN/dE = 1*10^-8 cm^-2s^-1sr^-1GeV. A gamma-ray burst
model following the formulation of Waxman and Bahcall would result in a 5-sigma
effect after the observation of 200 bursts in coincidence with satellite
observations of the gamma-rays.Comment: 33 pages, 13 figures, 6 table
Signatures for short-range correlations in {16}O, observed in the reaction {16}O(e,e'pp){14}C.
The reaction O-16(e,e'pp)C-14 has been studied at a transferred four-momentum (omega,\q\) = (210 MeV, 300 MeV/c). The differential cross sections for the transitions to the ground state and the lowest excited states in C-14 were determined as a function of the momentum of the recoiling C-14 nucleus and the angle between the momentum of the proton emitted in the forward direction and the momentum transfer q. A comparison of the data to the results of calculations, performed with a microscopic model, shows clear signatures for short-range correlations in the O-16 ground state
All-particle cosmic ray energy spectrum measured with 26 IceTop stations
We report on a measurement of the cosmic ray energy spectrum with the IceTop
air shower array, the surface component of the IceCube Neutrino Observatory at
the South Pole. The data used in this analysis were taken between June and
October, 2007, with 26 surface stations operational at that time, corresponding
to about one third of the final array. The fiducial area used in this analysis
was 0.122 km^2. The analysis investigated the energy spectrum from 1 to 100 PeV
measured for three different zenith angle ranges between 0{\deg} and 46{\deg}.
Because of the isotropy of cosmic rays in this energy range the spectra from
all zenith angle intervals have to agree. The cosmic-ray energy spectrum was
determined under different assumptions on the primary mass composition. Good
agreement of spectra in the three zenith angle ranges was found for the
assumption of pure proton and a simple two-component model. For zenith angles
{\theta} < 30{\deg}, where the mass dependence is smallest, the knee in the
cosmic ray energy spectrum was observed between 3.5 and 4.32 PeV, depending on
composition assumption. Spectral indices above the knee range from -3.08 to
-3.11 depending on primary mass composition assumption. Moreover, an indication
of a flattening of the spectrum above 22 PeV were observed.Comment: 38 pages, 17 figure
- âŠ