294 research outputs found

    The importance of transport model uncertainties for the estimation of CO2 sources and sinks using satellite measurements

    Get PDF
    This study presents a synthetic model intercomparison to investigate the importance of transport model errors for estimating the sources and sinks of CO2 using satellite measurements. The experiments were designed for testing the potential performance of the proposed CO2 lidar A-SCOPE, but also apply to other space borne missions that monitor total column CO2. The participating transport models IFS, LMDZ, TM3, and TM5 were run in forward and inverse mode using common a priori CO2 fluxes and initial concentrations. Forward simulations of column averaged CO2 (xCO2) mixing ratios vary between the models by s=0.5 ppm over the continents and s=0.27 ppm over the oceans. Despite the fact that the models agree on average on the sub-ppm level, these modest differences nevertheless lead to significant discrepancies in the inverted fluxes of 0.1 PgC/yr per 106 km2 over land and 0.03 PgC/yr per 106 km2 over the ocean. These transport model induced flux uncertainties exceed the target requirement that was formulated for the A-SCOPE mission of 0.02 PgC/yr per 106 km2, and could also limit the overall performance of other CO2 missions such as GOSAT. A variable, but overall encouraging agreement is found in comparison with FTS measurements at Park Falls, Darwin, Spitsbergen, and Bremen, although systematic differences are found exceeding the 0.5 ppm level. Because of this, our estimate of the impact of transport model uncerainty is likely to be conservative. It is concluded that to make use of the remote sensing technique for quantifying the sources and sinks of CO2 not only requires highly accurate satellite instruments, but also puts stringent requirements on the performance of atmospheric transport models. Improving the accuracy of these models should receive high priority, which calls for a closer collaboration between experts in atmospheric dynamics and tracer transpor

    Power-Based Droop Control in DC Microgrids Enabling Seamless Disconnection From Upstream Grids

    Get PDF
    This paper proposes a local power-based droop controller for distributed energy resource converters in dc microgrids that are connected to upstream grids by grid-interface converters. During normal operation, the grid-interface converter imposes the microgrid bus voltage, and the proposed controller allows power flow regulation at distributed energy resource converters\u2019 output. On the other hand, during abnormal operation of the grid-interface converter (e.g., due to faults in the upstream grid), the proposed controller allows bus voltage regulation by droop control. Notably, the controller can autonomously convert from power flow control to droop control, without any need of bus voltage variation detection schemes or communication with other microgrid components, which enables seamless transitions between these two modes of operation. Considering distributed energy resource converters employing the power-based droop control, the operation modes of a single converter and of the whole microgrid are defined and investigated herein. The controller design is also introduced. Furthermore, the power sharing performance of this control approach is analyzed and compared with that of classical droop control. The experimental results from a laboratory-scale dc microgrid prototype are reported to show the final performances of the proposed power-based droop control

    Airborne intercomparison of vacuum ultraviolet fluorescence and tunable diode laser absorption measurements of tropospheric carbon monoxide

    Get PDF
    During the fall 1997 North Atlantic Regional Experiment (NARE 97), two separate intercomparisons of aircraft-based carbon monoxide measurement instrumentation were conducted. On September 2, CO measurements were simultaneously made aboard the National Oceanic and Atmospheric Administration (NOAA) WP-3 by vacuum ultraviolet (VUV) fluorescence and by tunable diode laser absorption spectroscopy (TDLAS), On September 18, an intercomparison flight was conducted between two separate instruments, both employing the VUV fluorescence method, on the NOAA WP-3 and the U,K. Meteorological Office C-130 Hercules. The results indicate that both of the VUV fluorescence instruments and the TDLAS system are capable of measuring ambient CO accurately and precisely with no apparent interferences in 5 s. The accuracy of the measurements, based upon three independent calibration systems, is indicated by the agreement to within 11% with systematic offsets of less than 1 ppbv. In addition, one of the groups participated in the Measurement of Air Pollution From Satellite (MAPS) intercomparison [Novelli ef at., 1998] with a different measurement technique but very similar calibration system, and agreed with the accepted analysis to within 5%. The precision of the measurements is indicated by the variability of the ratio of simultaneous measurements from the separate instruments, This variability is consistent with the estimated precisions of 1.5 ppbv and 2.2 ppbv for the 5 s average results of the C-130 and the WP-3 instruments, respectively, and indicates a precision of approximately 3.6% for the TDLAS instrument. The excellent agreement of the instruments in both intercomparisons demonstrates that significant interferences in the measurements are absent in air masses that ranged from 7 km in the midtroposphere to boundary layer conditions including subtropical marine air and continental outflow with embedded urban plumes. The intercomparison of the two VUV instruments that differed widely in their design indicates that the VUV fluorescence technique for CO measurements is not particularly sensitive to the details of its implementation. These intercomparisons help to establish the reliability of ambient CO measurements by the VUV fluorescence technique

    COCAP : a carbon dioxide analyser for small unmanned aircraft systems

    Get PDF
    Unmanned aircraft systems (UASs) could provide a cost-effective way to close gaps in the observation of the carbon cycle, provided that small yet accurate analysers are available. We have developed a COmpact Carbon dioxide analyser for Airborne Platforms (COCAP). The accuracy of COCAP's carbon dioxide (CO2) measurements is ensured by calibration in an environmental chamber, regular calibration in the field and by chemical drying of sampled air. In addition, the package contains a lightweight thermal stabilisation system that reduces the influence of ambient temperature changes on the CO2 sensor by 2 orders of magnitude. During validation of COCAP's CO2 measurements in simulated and real flights we found a measurement error of 1.2 mu mol mol(-1) or better with no indication of bias. COCAP is a self-contained package that has proven well suited for the operation on board small UASs. Besides carbon dioxide dry air mole fraction it also measures air temperature, humidity and pressure. We describe the measurement system and our calibration strategy in detail to support others in tapping the potential of UASs for atmospheric trace gas measurements.Peer reviewe

    Characterization of a neutralizing monoclonal antibody to Pasteurella haemolytica leukotoxin.

    Get PDF
    Six hybridoma clones producing monoclonal antibodies (MAbs) reactive with Pasteurella haemolytica A1 leukotoxin were derived from mice immunized with leukotoxin excised from sodium dodecyl sulfate-polyacrylamide gels. Of the six MAbs, only one, Ltx-2, neutralized leukotoxin in a BL-3 cell cytotoxicity assay. MAb Ltx-2 blocked association of A1 leukotoxin to BL-3 cells, as measured by flow cytometric analysis. The epitope recognized by Ltx-2 was localized to the carboxyl half of the native protein, between residues 450 and 939, by Western immunoblot analysis of CNBr fragments. Further analysis with leukotoxin deletion proteins indicated either that the Ltx-2-reactive epitope was localized in the carboxyl portion of the leukotoxin between amino acids 768 and 939 or that this region influences MAb recognition of the epitope. MAb Ltx-2 was tested for neutralizing activity against leukotoxin produced by P. haemolytica serotypes 1 through 12. The MAb neutralized leukotoxin produced by all of the A biotype isolates (serotypes 1, 5, 6, 7, 8, 9, and 12), with the exception of serotype A2, but did not neutralize any T biotype leukotoxin tested (T3, T4, or T10). The results indicate that MAb Ltx-2 neutralizes leukotoxin by interfering with target cell association and that the MAb-specific epitope is either not present or not critical for function in the leukotoxin produced by P. haemolytica serotypes A2, T3, T4, and T10

    Constraining Fossil Fuel CO2 Emissions From Urban Area Using OCO‐2 Observations of Total Column CO2

    Full text link
    Satellite observations of the total column dry‐air CO2 (XCO2) are expected to support the quantification and monitoring of fossil fuel CO2 (ffCO2) emissions from urban areas. We evaluate the utility of the Orbiting Carbon Observatory 2 (OCO‐2) XCO2 retrievals to optimize whole‐city emissions, using a Bayesian inversion system and high‐resolution transport modeling. The uncertainties of constrained emissions related to transport model, satellite measurements, and local biospheric fluxes are quantified. For the first two uncertainty sources, we examine cities of different landscapes: “plume city” located in relatively flat terrain, represented by Riyadh and Cairo; and “basin city” located in basin terrain, represented by Los Angeles (LA). The retrieved scaling factors of emissions and their uncertainties show prominent variabilities from track to track, due to the varying meteorological conditions and relative locations of the tracks transecting plumes. To explore the performance of multiple tracks in retrieving emissions, pseudo data experiments are carried out. The estimated least numbers of tracks required to constrain the total emissions for Riyadh (<10% uncertainty), Cairo (<10%), and LA (<5%) are 8, 5, and 7, respectively. Additionally, to evaluate the impact of biospheric fluxes on derivation of the ffXCO2 enhancements, we conduct simulations for Pearl River Delta metropolitan area. Significant fractions of local XCO2 enhancements associated with local biospheric XCO2 variations are shown, which potentially lead to biased estimates of ffCO2 emissions. We demonstrate that satellite measurements can be used to improve urban ffCO2 emissions with a sufficient amount of measurements and appropriate representations of the uncertainty components.Key PointsInversion method is utilized to constrain whole‐city fossil fuel emissions with measurement and transport model errors consideredPotential of incorporating multiple tracks to obtain regular emission estimates is evaluated by pseudo data experimentsSignificant contribution of the biospheric fluxes variability to local XCO2 variation is demonstratedPeer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/154979/1/jgrd56150_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/154979/2/jgrd56150.pd

    Bridging the gap between atmospheric concentrations and local ecosystem measurements

    Get PDF
    This paper demonstrates that atmospheric inversions of CO<sub>2</sub> are a reliable tool for estimating regional fluxes. We compare results of an inversion over 18 days and a 300 x 300 km 2 domain in southwest France against independent measurements of fluxes from aircraft and towers. The inversion used concentration measurements from 2 towers while the independent data included 27 aircraft transects and 5 flux towers. The inversion reduces the mismatch between prior and independent fluxes, improving both spatial and temporal structures. The present mesoscale atmospheric inversion improves by 30% the CO<sub>2</sub> fluxes over distances of few hundreds of km around the atmospheric measurement locations. Citation: Lauvaux, T., et al. (2009), Bridging the gap between atmospheric concentrations and local ecosystem measurements, Geophys. Res. Lett., 36, L19809, doi: 10.1029/2009GL039574

    A multi-year methane inversion using SCIAMACHY, accounting for systematic errors using TCCON measurements

    Get PDF
    This study investigates the use of total column CH<sub>4</sub> (<i>X</i>CH<sub>4</sub>) retrievals from the SCIAMACHY satellite instrument for quantifying large-scale emissions of methane. A unique data set from SCIAMACHY is available spanning almost a decade of measurements, covering a period when the global CH<sub>4</sub> growth rate showed a marked transition from stable to increasing mixing ratios. The TM5 4DVAR inverse modelling system has been used to infer CH<sub>4</sub> emissions from a combination of satellite and surface measurements for the period 2003–2010. In contrast to earlier inverse modelling studies, the SCIAMACHY retrievals have been corrected for systematic errors using the TCCON network of ground-based Fourier transform spectrometers. The aim is to further investigate the role of bias correction of satellite data in inversions. Methods for bias correction are discussed, and the sensitivity of the optimized emissions to alternative bias correction functions is quantified. It is found that the use of SCIAMACHY retrievals in TM5 4DVAR increases the estimated inter-annual variability of large-scale fluxes by 22% compared with the use of only surface observations. The difference in global methane emissions between 2-year periods before and after July 2006 is estimated at 27–35 Tg yr<sup>−1</sup>. The use of SCIAMACHY retrievals causes a shift in the emissions from the extra-tropics to the tropics of 50 ± 25 Tg yr<sup>−1</sup>. The large uncertainty in this value arises from the uncertainty in the bias correction functions. Using measurements from the HIPPO and BARCA aircraft campaigns, we show that systematic errors in the SCIAMACHY measurements are a main factor limiting the performance of the inversions. To further constrain tropical emissions of methane using current and future satellite missions, extended validation capabilities in the tropics are of critical importance
    • 

    corecore