414 research outputs found
Meeting the Goals of Service Learning in Pharmacy Education through Community Campus Partnerships
Healthy People 2010, published by the US Department of Health and Human Services, is a statement of health objectives for the nation to be achieved by the end of this decade. The goals are to increase quality and years of healthy life and to eliminate health disparities. In 2006, the West Virginia University School of Pharmacy began a revision to its Doctor of Pharmacy curriculum to include pharmacy practice experiences that would provide students with experience in developing disease prevention and health promotion programming in the community. Thus, the School of Pharmacy began a three-semester longitudinal service learning program which focused on advancing the objectives of Healthy People 2010 through service learning. The experiences of the School of Pharmacy service learning program from 2006 to the present are detailed
Multiproxy investigation of the last 2,000 years BP marine paleoenvironmental record along the western Spitsbergen margin
A reconstruction of the last 2,000 years BP of environmental and oceanographic changes on the western margin of Spitsbergen was performed using a multidisciplinary approach including the fossil assemblages of diatoms, planktic and benthic foraminifera and calcareous nannofossils and the use of geochemistry (X-ray fluorescence spectroscopy, X-ray diffraction). We identified two warm periods (2,000–1,600 years BP and 1,300–700 years BP) that were associated with the Roman Warm Period and the Medieval Warm Period that alternate with colder oceanic conditions and sea ice coverage occurred during the Dark Ages (1,600–1,300 years BP) and the beginning of the Little Ice Age. During the Medieval Warm Period the occurrence of ice-rafted debris and Aulocoseira spp., a specific diatom genus commonly associated with continental freshwater, suggests significant runoff of meltwaters from local glaciers
NN coupling and two-pion photoproduction on the nucleon
Effects of non-resonant photoproductions arising from two different
couplings are investigated in the reaction. We find that
the pseudoscalar (PS) coupling is generally preferable to the
pseudovector (PV) coupling and particularly the total cross sections
are successfully described by the model with the PS coupling. In order
to see the difference between the two couplings, we also show the results of
invariant mass spectra and helicity-dependent cross sections in various isospin
channels calculated with the PS and PV couplings.Comment: 35 pages, 11 figures, minor changes and version to be published in
Phys.Rev.
Cerebrovascular reactivity is not associated with therapeutic intensity in adult traumatic brain injury: a CENTER-TBI analysis.
BACKGROUND: Impaired cerebrovascular reactivity in adult traumatic brain injury (TBI) is known to be associated with poor outcome. However, there has yet to be an analysis of the association between the comprehensively assessed intracranial hypertension therapeutic intensity level (TIL) and cerebrovascular reactivity. METHODS: Using the Collaborative European Neuro Trauma Effectiveness Research in TBI (CENTER-TBI) high-resolution intensive care unit (ICU) cohort, we derived pressure reactivity index (PRx) as the moving correlation coefficient between slow-wave in ICP and mean arterial pressure, updated every minute. Mean daily PRx, and daily % time above PRx of 0 were calculated for the first 7 days of injury and ICU stay. This data was linked with the daily TIL-Intermediate scores, including total and individual treatment sub-scores. Daily mean PRx variable values were compared for each TIL treatment score via mean, standard deviation, and the Mann U test (Bonferroni correction for multiple comparisons). General fixed effects and mixed effects models for total TIL versus PRx were created to display the relation between TIL and cerebrovascular reactivity. RESULTS: A total of 249 patients with 1230 ICU days of high frequency physiology matched with daily TIL, were assessed. Total TIL was unrelated to daily PRx. Most TIL sub-scores failed to display a significant relationship with the PRx variables. Mild hyperventilation (p < 0.0001), mild hypothermia (p = 0.0001), high levels of sedation for ICP control (p = 0.0001), and use vasopressors for CPP management (p < 0.0001) were found to be associated with only a modest decrease in mean daily PRx or % time with PRx above 0. CONCLUSIONS: Cerebrovascular reactivity remains relatively independent of intracranial hypertension therapeutic intensity, suggesting inadequacy of current TBI therapies in modulating impaired autoregulation. These findings support the need for investigation into the molecular mechanisms involved, or individualized physiologic targets (ICP, CPP, or Co2) in order to treat dysautoregulation actively.EU 7th Framewor
Severe traumatic brain injury : targeted management in the intensive care unit
Severe traumatic brain injury (TBI) is currently managed in the intensive care unit with a combined medical-surgical approach. Treatment aims to prevent additional brain damage and to optimise conditions for brain recovery. TBI is typically considered and treated as one pathological entity, although in fact it is a syndrome comprising a range of lesions that can require different therapies and physiological goals. Owing to advances in monitoring and imaging, there is now the potential to identify specific mechanisms of brain damage and to better target treatment to individuals or subsets of patients. Targeted treatment is especially relevant for elderly people-who now represent an increasing proportion of patients with TBI-as preinjury comorbidities and their therapies demand tailored management strategies. Progress in monitoring and in understanding pathophysiological mechanisms of TBI could change current management in the intensive care unit, enabling targeted interventions that could ultimately improve outcomes.Peer reviewe
A search for the analogue to Cherenkov radiation by high energy neutrinos at superluminal speeds in ICARUS
The OPERA collaboration has claimed evidence of superluminal {\nu}{_\mu}
propagation between CERN and the LNGS. Cohen and Glashow argued that such
neutrinos should lose energy by producing photons and e+e- pairs, through Z0
mediated processes analogous to Cherenkov radiation. In terms of the parameter
delta=(v^2_nu-v^2_c)/v^2_c, the OPERA result implies delta = 5 x 10^-5. For
this value of \delta a very significant deformation of the neutrino energy
spectrum and an abundant production of photons and e+e- pairs should be
observed at LNGS. We present an analysis based on the 2010 and part of the 2011
data sets from the ICARUS experiment, located at Gran Sasso National Laboratory
and using the same neutrino beam from CERN. We find that the rates and
deposited energy distributions of neutrino events in ICARUS agree with the
expectations for an unperturbed spectrum of the CERN neutrino beam. Our results
therefore refute a superluminal interpretation of the OPERA result according to
the Cohen and Glashow prediction for a weak current analog to Cherenkov
radiation. In particular no superluminal Cherenkov like e+e- pair or gamma
emission event has been directly observed inside the fiducial volume of the
"bubble chamber like" ICARUS TPC-LAr detector, setting the much stricter limit
of delta < 2.5 10^-8 at the 90% confidence level, comparable with the one due
to the observations from the SN1987A.Comment: 17 pages, 6 figure
Underground operation of the ICARUS T600 LAr-TPC: first results
Open questions are still present in fundamental Physics and Cosmology, like
the nature of Dark Matter, the matter-antimatter asymmetry and the validity of
the particle interaction Standard Model. Addressing these questions requires a
new generation of massive particle detectors exploring the subatomic and
astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of
a novel detector generation able to combine the imaging capabilities of the old
famous "bubble chamber" with an excellent energy measurement in huge electronic
detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory,
studying cosmic rays, neutrino oscillation and proton decay. Physical
potentialities of this novel telescope are presented through few examples of
neutrino interactions reconstructed with unprecedented details. Detector design
and early operation are also reported.Comment: 14 pages, 8 figures, 2 tables. Submitted to Jins
Changing care pathways and between-center practice variations in intensive care for traumatic brain injury across Europe: a CENTER-TBI analysis.
PURPOSE: To describe ICU stay, selected management aspects, and outcome of Intensive Care Unit (ICU) patients with traumatic brain injury (TBI) in Europe, and to quantify variation across centers. METHODS: This is a prospective observational multicenter study conducted across 18 countries in Europe and Israel. Admission characteristics, clinical data, and outcome were described at patient- and center levels. Between-center variation in the total ICU population was quantified with the median odds ratio (MOR), with correction for case-mix and random variation between centers. RESULTS: A total of 2138 patients were admitted to the ICU, with median age of 49 years; 36% of which were mild TBI (Glasgow Coma Scale; GCS 13-15). Within, 72 h 636 (30%) were discharged and 128 (6%) died. Early deaths and long-stay patients (> 72 h) had more severe injuries based on the GCS and neuroimaging characteristics, compared with short-stay patients. Long-stay patients received more monitoring and were treated at higher intensity, and experienced worse 6-month outcome compared to short-stay patients. Between-center variations were prominent in the proportion of short-stay patients (MOR = 2.3, p < 0.001), use of intracranial pressure (ICP) monitoring (MOR = 2.5, p < 0.001) and aggressive treatments (MOR = 2.9, p < 0.001); and smaller in 6-month outcome (MOR = 1.2, p = 0.01). CONCLUSIONS: Half of contemporary TBI patients at the ICU have mild to moderate head injury. Substantial between-center variations exist in ICU stay and treatment policies, and less so in outcome. It remains unclear whether admission of short-stay patients represents appropriate prudence or inappropriate use of clinical resources
Measurement of Through-Going Particle Momentum By Means Of Multiple Scattering With The ICARUS T600 TPC
The ICARUS collaboration has demonstrated, following the operation of a 600
ton (T600) detector at shallow depth, that the technique based on liquid Argon
TPCs is now mature. The study of rare events, not contemplated in the Standard
Model, can greatly benefit from the use of this kind of detectors. In
particular, a deeper understanding of atmospheric neutrino properties will be
obtained thanks to the unprecedented quality of the data ICARUS provides.
However if we concentrate on the T600 performance, most of the
charged current sample will be partially contained, due to the reduced
dimensions of the detector. In this article, we address the problem of how well
we can determine the kinematics of events having partially contained tracks.
The analysis of a large sample of atmospheric muons collected during the T600
test run demonstrate that, in case the recorded track is at least one meter
long, the muon momentum can be reconstructed by an algorithm that measures the
Multiple Coulomb Scattering along the particle's path. Moreover, we show that
momentum resolution can be improved by a factor two using an algorithm based on
the Kalman Filtering technique
Discovery of underground argon with low level of radioactive 39Ar and possible applications to WIMP dark matter detectors
We report on the first measurement of 39Ar in argon from underground natural
gas reservoirs. The gas stored in the US National Helium Reserve was found to
contain a low level of 39Ar. The ratio of 39Ar to stable argon was found to be
<=4x10-17 (84% C.L.), less than 5% the value in atmospheric argon
(39Ar/Ar=8x10-16). The total quantity of argon currently stored in the National
Helium Reserve is estimated at 1000 tons. 39Ar represents one of the most
important backgrounds in argon detectors for WIMP dark matter searches. The
findings reported demonstrate the possibility of constructing large multi-ton
argon detectors with low radioactivity suitable for WIMP dark matter searches.Comment: 6 pages, 2 figures, 2 table
- …