128 research outputs found
Fast-field cycling NMR is sensitive to the method of cross-linking in BSA gels
This work was supported by ARUK (grant number 19689).Non peer reviewedPublisher PD
Fast field-cycling NMR of cartilage : a way toward molecular imaging
Peer reviewedPublisher PD
A cross-center smoothness prior for variational Bayesian brain tissue segmentation
Suppose one is faced with the challenge of tissue segmentation in MR images,
without annotators at their center to provide labeled training data. One option
is to go to another medical center for a trained classifier. Sadly, tissue
classifiers do not generalize well across centers due to voxel intensity shifts
caused by center-specific acquisition protocols. However, certain aspects of
segmentations, such as spatial smoothness, remain relatively consistent and can
be learned separately. Here we present a smoothness prior that is fit to
segmentations produced at another medical center. This informative prior is
presented to an unsupervised Bayesian model. The model clusters the voxel
intensities, such that it produces segmentations that are similarly smooth to
those of the other medical center. In addition, the unsupervised Bayesian model
is extended to a semi-supervised variant, which needs no visual interpretation
of clusters into tissues.Comment: 12 pages, 2 figures, 1 table. Accepted to the International
Conference on Information Processing in Medical Imaging (2019
Open‐source magnetic resonance imaging: improving access, science, and education through global collaboration
Open-source practices and resources in magnetic resonance imaging (MRI) have increased substantially in recent years. This trend started with software and data being published open-source and, more recently, open-source hardware designs have become increasingly available. These developments towards a culture of sharing and establishing nonexclusive global collaborations have already improved the reproducibility and reusability of code and designs, while providing a more inclusive approach, especially for low-income settings. Community-driven standardization and documentation efforts are further strengthening and expanding these milestones. The future of open-source MRI is bright and we have just started to discover its full collaborative potential. In this review we will give an overview of open-source software and open-source hardware projects in human MRI research
Medical Applications of Fast Field Cycling MRI
Non peer reviewedPublisher PD
OFTATLAS. ATLAS CUBANO DE OFTALMOLOGÍA
El desarrollo de la tecnología de la computación ha permitido la introducción, en la práctica docente, de nuevos medios de enseñanza que han revolucionado la docencia médica. La utilización del software educativo como medio que facilite el proceso de enseñanza aprendizaje en las diferentes carreras de las Ciencias Médicas es hoy una realidad en nuestras universidades. Este trabajo consiste en un software educativo como material complementario para la enseñanza de la oftalmología en Cuba, tanto para pregrado como para postgrado e incluye materiales audiovisuales para el aprendizaje no solo de la oftalmología clínica sino también quirúrgica. Se utilizó la herramienta de Crheasoft para la realización del producto final, con una combinación de elementos visuales y auditivos. Teniendo en cuenta el antiguo proverbio “más vale ver una vez que oír cien veces”, se confeccionó este atlas interactivo que tiene como finalidad proporcionar un material educativo didáctico de consulta y de apoyo a la docencia, útil para el desarrollo de una metodología de enseñanza más adaptable a las características individuales de cada usuario. El software cuenta con una interfaz que permite la fácil navegación, posibilitando la interacción y el intercambio de información entre el usuario y la aplicación.PALABRAS CLAVE:Atlas, oftalmología, software
Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring.
Purpose: Ultrashort echo time (UTE) MRI has been proposed as a way to produce segmented attenuation maps for PET, as it provides contrast between bone, air, and soft tissue. However, UTE sequences require samples to be acquired during rapidly changing gradient fields, which makes the resulting images prone to eddy current artifacts. In this work it is demonstrated that this can lead to misclassification of tissues in segmented attenuation maps (AC maps) and that these effects can be corrected for by measuring the true k-space trajectories using a magnetic field camera. Methods: The k-space trajectories during a dual echo UTE sequence were measured using a dynamic magnetic field camera. UTE images were reconstructed using nominal trajectories and again using the measured trajectories. A numerical phantom was used to demonstrate the effect of reconstructing with incorrect trajectories. Images of an ovine leg phantom were reconstructed and segmented and the resulting attenuation maps were compared to a segmented map derived from a CT scan of the same phantom, using the Dice similarity measure. The feasibility of the proposed method was demonstrated in in vivo cranial imaging in five healthy volunteers. Simulated PET data were generated for one volunteer to show the impact of misclassifications on the PET reconstruction. Results: Images of the numerical phantom exhibited blurring and edge artifacts on the bone-tissue and air-tissue interfaces when nominal k-space trajectories were used, leading to misclassification of soft tissue as bone and misclassification of bone as air. Images of the tissue phantom and the in vivo cranial images exhibited the same artifacts. The artifacts were greatly reduced when the measured trajectories were used. For the tissue phantom, the Dice coefficient for bone in MR relative to CT was 0.616 using the nominal trajectories and 0.814 using the measured trajectories. The Dice coefficients for soft tissue were 0.933 and 0.934 for the nominal and measured cases, respectively. For air the corresponding figures were 0.991 and 0.993. Compared to an unattenuated reference image, the mean error in simulated PET uptake in the brain was 9.16% when AC maps derived from nominal trajectories was used, with errors in the SUV max for simulated lesions in the range of 7.17%-12.19%. Corresponding figures when AC maps derived from measured trajectories were used were 0.34% (mean error) and -0.21% to +1.81% (lesions). CONCLUSIONS: Eddy current artifacts in UTE imaging can be corrected for by measuring the true k-space trajectories during a calibration scan and using them in subsequent image reconstructions. This improves the accuracy of segmented PET attenuation maps derived from UTE sequences and subsequent PET reconstruction
Fear of COVID‐19 Scale (FCV‐19S) across countries: measurement invariance issues
Aim: The threats of novel coronavirus disease 2019 (COVID-19) have caused fears worldwide. The Fear of COVID-19 Scale (FCV-19S) was recently developed to assess the fear of COVID-19. Although many studies found that the FCV-19S is psychometrically sound, it is unclear whether the FCV-19S is invariant across countries. The present study aimed to examine the measurement invariance of the FCV-19S across eleven countries.
Design: Cross-sectional study.
Methods: Using data collected from prior research on Bangladesh (N = 8,550), United Kingdom (N = 344), Brazil (N = 1,843), Taiwan (N = 539), Italy (N = 249), New Zealand (N = 317), Iran (N = 717), Cuba (N = 772), Pakistan (N = 937), Japan (N = 1,079) and France (N = 316), comprising a total 15,663 participants, the present study used the multigroup confirmatory factor analysis (CFA) and Rasch differential item functioning (DIF) to examine the measurement invariance of the FCV-19S across country, gender and age (children aged below 18 years, young to middle-aged adults aged between 18 and 60 years, and older people aged above 60 years).
Results: The unidimensional structure of the FCV-19S was confirmed. Multigroup CFA showed that FCV-19S was partially invariant across country and fully invariant across gender and age. DIF findings were consistent with the findings from multigroup CFA. Many DIF items were displayed for country, few DIF items were displayed for age, and no DIF items were displayed for gender.
Conclusion: Based on the results of the present study, the FCV-19S is a good psychometric instrument to assess fear of COVID-19 during the pandemic period. Moreover, the use of FCV-19S is supported in at least ten countries with satisfactory psychometric properties
Biophysical Characteristics Reveal Neural Stem Cell Differentiation Potential
Distinguishing human neural stem/progenitor cell (huNSPC) populations that will predominantly generate neurons from those that produce glia is currently hampered by a lack of sufficient cell type-specific surface markers predictive of fate potential. This limits investigation of lineage-biased progenitors and their potential use as therapeutic agents. A live-cell biophysical and label-free measure of fate potential would solve this problem by obviating the need for specific cell surface markers
- …