143 research outputs found

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM

    The Cholecystectomy As A Day Case (CAAD) Score: A Validated Score of Preoperative Predictors of Successful Day-Case Cholecystectomy Using the CholeS Data Set

    Get PDF
    Background Day-case surgery is associated with significant patient and cost benefits. However, only 43% of cholecystectomy patients are discharged home the same day. One hypothesis is day-case cholecystectomy rates, defined as patients discharged the same day as their operation, may be improved by better assessment of patients using standard preoperative variables. Methods Data were extracted from a prospectively collected data set of cholecystectomy patients from 166 UK and Irish hospitals (CholeS). Cholecystectomies performed as elective procedures were divided into main (75%) and validation (25%) data sets. Preoperative predictors were identified, and a risk score of failed day case was devised using multivariate logistic regression. Receiver operating curve analysis was used to validate the score in the validation data set. Results Of the 7426 elective cholecystectomies performed, 49% of these were discharged home the same day. Same-day discharge following cholecystectomy was less likely with older patients (OR 0.18, 95% CI 0.15–0.23), higher ASA scores (OR 0.19, 95% CI 0.15–0.23), complicated cholelithiasis (OR 0.38, 95% CI 0.31 to 0.48), male gender (OR 0.66, 95% CI 0.58–0.74), previous acute gallstone-related admissions (OR 0.54, 95% CI 0.48–0.60) and preoperative endoscopic intervention (OR 0.40, 95% CI 0.34–0.47). The CAAD score was developed using these variables. When applied to the validation subgroup, a CAAD score of ≤5 was associated with 80.8% successful day-case cholecystectomy compared with 19.2% associated with a CAAD score >5 (p < 0.001). Conclusions The CAAD score which utilises data readily available from clinic letters and electronic sources can predict same-day discharges following cholecystectomy

    An electrochemical model of the transport of charged molecules through the capillary glycocalyx.

    No full text
    An electrochemical theory of the glycocalyx surface layer on capillary endothelial cells is developed as a model to study the electrochemical dynamics of anionic molecular transport within capillaries. Combining a constitutive relationship for electrochemical transport, derived from Fick's and Ohm's laws, with the conservation of mass and Gauss's law from electrostatics, a system of three nonlinear, coupled, second-order, partial, integro-differential equations is obtained for the concentrations of the diffusing anionic molecules and the cations and anions in the blood. With the exception of small departures from electroneutrality that arise locally near the apical region of the glycocalyx, the model assumes that cations in the blood counterbalance the fixed negative charges bound to the macromolecular matrix of the glycocalyx in equilibrium. In the presence of anionic molecular tracers injected into the capillary lumen, the model predicts the size- and charge-dependent electrophoretic mobility of ions and tracers within the layer. In particular, the model predicts that anionic molecules are excluded from the glycocalyx at equilibrium and that the extent of this exclusion, which increases with increasing tracer and/or glycocalyx electronegativity, is a fundamental determinant of anionic molecular transport through the layer. The model equations were integrated numerically using a Crank-Nicolson finite-difference scheme and Newton-Raphson iteration. When the concentration of the anionic molecular tracer is small compared with the concentration of ions in the blood, a linearized version of the model can be obtained and solved as an eigenvalue problem. The results of the linear and nonlinear models were found to be in good agreement for this physiologically important case. Furthermore, if the fixed-charge density of the glycocalyx is of the order of the concentration of ions in the blood, or larger, or if the magnitude of the anionic molecular valence is large, a closed-form asymptotic solution for the diffusion time can be obtained from the eigenvalue problem that compares favorably with the numerical solution. In either case, if leakage of anionic molecules out of the capillary occurs, diffusion time is seen to vary exponentially with anionic valence and in inverse proportion to the steady-state anionic tracer concentration in the layer relative to the lumen. These findings suggest several methods for obtaining an estimate of the glycocalyx fixed-charge density in vivo
    • …
    corecore