2,419 research outputs found
The mid-infrared spectrum of the transiting exoplanet HD 209458b
We report the spectroscopic detection of mid-infrared emission from the
transiting exoplanet HD 209458b. Using archive data taken with the Spitzer/IRS
instrument, we have determined the spectrum of HD 209458b between 7.46 and
15.25 microns. We have used two independent methods to determine the planet
spectrum, one differential in wavelength and one absolute, and find the results
are in good agreement. Over much of this spectral range, the planet spectrum is
consistent with featureless thermal emission. Between 7.5 and 8.5 microns, we
find evidence for an unidentified spectral feature. If this spectral modulation
is due to absorption, it implies that the dayside vertical temperature profile
of the planetary atmosphere is not entirely isothermal. Using the IRS data, we
have determined the broad-band eclipse depth to be 0.00315 +/- 0.000315,
implying significant redistribution of heat from the dayside to the nightside.
This work required development of improved methods for Spitzer/IRS data
calibration that increase the achievable absolute calibration precision and
dynamic range for observations of bright point sources.Comment: 35 pages, 12 figures, revised version accepted by the Astrophysical
Journa
DDT and Malaria Prevention: Addressing the Paradox
Background: The debate regarding dichlorodiphenyltrichloroethane (DDT) in malaria prevention and human health is polarized and can be classified into three positions: anti-DDT, centrist-DDT, pro-DDT. Objective: We attempted to arrive at a synthesis by matching a series of questions on the use of DDT for indoor residual spraying (IRS) with literature and insights, and to identify options and opportunities. Discussion: Overall, community health is significantly improved through all available malaria control measures, which include IRS with DDT. Is DDT “good”? Yes, because it has saved many lives. Is DDT safe as used in IRS? Recent publications have increasingly raised concerns about the health implications of DDT. Therefore, an unqualified statement that DDT used in IRS is safe is untenable. Are inhabitants and applicators exposed? Yes, and to high levels. Should DDT be used? The fact that DDT is “good” because it saves lives, and “not safe” because it has health and environmental consequences, raises ethical issues. The evidence of adverse human health effects due to DDT is mounting. However, under certain circumstances, malaria control using DDT cannot yet be halted. Therefore, the continued use of DDT poses a paradox recognized by a centrist-DDT position. At the very least, it is now time to invoke precaution. Precautionary actions could include use and exposure reduction. Conclusions: There are situations where DDT will provide the best achievable health benefit, but maintaining that DDT is safe ignores the cumulative indications of many studies. In such situations, addressing the paradox from a centrist-DDT position and invoking precaution will help design choices for healthier lives
Young stars in Epsilon Cha and their disks: disk evolution in sparse associations
(abridge) The nearby young stellar association Epsilon Cha association has an
estimated age of 3-5 Myr, making it an ideal laboratory to study the disk
dissipation process and provide empirical constraints on the timescale of
planet formation. We combine the available literature data with our Spitzer IRS
spectroscopy and VLT/VISIR imaging data. The very low mass stars USNO-B120144.7
and 2MASS J12005517 show globally depleted spectral energy distributions
pointing at strong dust settling. 2MASS J12014343 may have a disk with a very
specific inclination where the central star is effectively screened by the cold
outer parts of a flared disk but the 10 micron radiation of the warm inner disk
can still reach us. We find the disks in sparse stellar associations are
dissipated more slowly than those in denser (cluster) environments. We detect
C_{2}H_{2} rovibrational band around 13.7 micron on the IRS spectrum of
USNO-B120144.7. We find strong signatures of grain growth and crystallization
in all Epsilon Cha members with 10 micron features detected in their IRS
spectra. We combine the dust properties derived in the Epsilon Cha sample with
those found using identical or similar methods in the MBM 12, Coronet cluster,
Eta Cha associations, and in the cores to disks (c2d) legacy program. We find
that disks around low-mass young stars show a negative radial gradient in the
mass-averaged grain size and mass fraction of crystalline silicates. A positive
correlation exists between the mass-averaged grain sizes of amorphous silicates
and the accretion rates if the latter is above ~10^{-9} Msun/yr, possibly
indicating that those disks are sufficiently turbulent to prevent grains of
several microns in size to sink into the disk interior.Comment: 17 pages, 18 figures, 6 tables, language revised; accepted to A&
Molecular Signatures in the Near Infrared Dayside Spectrum of HD 189733b
We have measured the dayside spectrum of HD 189733b between 1.5 and 2.5
microns using the NICMOS instrument on the Hubble Space Telescope. The emergent
spectrum contains significant modulation, which we attribute to the presence of
molecular bands seen in absorption. We find that water (H2O), carbon monoxide
(CO), and carbon dioxide (CO2) are needed to explain the observations, and we
are able to estimate the mixing ratios for these molecules. We also find
temperature decreases with altitude in the ~0.01 < P < ~1 bar region of the
dayside near-infrared photosphere and set an upper limit to the dayside
abundance of methane (CH4) at these pressures.Comment: 13 pages, 3 figures. accepted in Astrophysical Journal Letter
Is there a mismatch between the perspectives of patients and regulators on healthcare quality?:A survey study
Objectives: Internationally, healthcare quality regulators are criticized for failing to respond to patients' complaints. Patient involvement is, therefore, an important item on the policy agenda. However, it can be argued that there is a discrepancy between the patients' perspective and current regulatory approaches. This study examines whether a discrepancy exists between the perspectives of patients and regulators on healthcare quality. Methods: A questionnaire was sent to 996 people who had registered a complaint with the Dutch Healthcare Inspectorate to measure expectations of and experiences with the Inspectorate. A taxonomy was used to classify their complaints into the clinical, relationship, or management domains. Results: The response was 54%. More complaints about clinical issues (56%, P = 0.000) were investigated by the regulator than complaints about organizational (37%) and relational issues (51%). Patients with complaints about management issues less often indicated (13%, P = 0.002) that healthcare is improved by making their complaint than patients with complaints about clinical or relationship issues did (22%–23%). Patients who reported about relational issues with care providers attached more importance to issuing sanctions against the care provider than other patients (mean score 2.89 versus 2.62–2.68, P = 0.006). Conclusions: The predominant clinical approach taken by regulators does not match the patients' perspective of what is relevant for healthcare quality. In addition, patients seem to be more tolerant of what they perceive to be clinical or management errors than of perceived relational deficiencies in care providers. If regulators want to give patients a voice, they should expand their horizon beyond the medical framework
Structure in cohesive powders studied with spin-echo small angle\ud neutron scattering
Extracting structure and ordering information from the bulk of granular materials is a challenging task. Here we present Spin-Echo Small Angle Neutron Scattering Measurements in combination with computer simulations on a fine powder of silica, before and after uniaxial compression. The cohesive powder packing is modeled by using molecular dynamics simulations and the structure, in terms of the density–density correlation function, is calculated from the simulation and compared with experiment. In the dense case, both quantitative and qualitative agreement between measurement and simulations is observed, thus creating the desired link between experiment and computer simulation. Further simulations with appropriate attractive potentials and adequate preparation procedures are needed in order to capture the very loose-packed cohesive powders.\u
Concept for a Time-of-Flight Small Angle Neutron Scattering Instrument at the European Spallation Source
A new Small Angle Neutron Scattering instrument is proposed for the European
Spallation Source. The pulsed source requires a time-of-flight analysis of the
gathered neutrons at the detector. The optimal instrument length is found to be
rather large, which allows for a polarizer and a versatile collimation. The
polarizer allows for studying magnetic samples and incoherent background
subtraction. The wide collimation will host VSANS and SESANS options that
increase the resolution of the instrument towards um and tens of um,
respectively. Two 1m2 area detectors will cover a large solid angle
simultaneously. The expected gains for this new instrument will lie in the
range between 20 and 36, depending on the assessment criteria, when compared to
up-to-date reactor based instruments. This will open new perspectives for fast
kinetics, weakly scattering samples, and multi-dimensional contrast variation
studies.Comment: 18 pages, 10 figure
The Formation and Evolution of Planetary Systems: Description of the Spitzer Legacy Science Database
We present the science database produced by the Formation and Evolution of
Planetary Systems (FEPS) Spitzer Legacy program. Data reduction and validation
procedures for the IRAC, MIPS, and IRS instruments are described in detail. We
also derive stellar properties for the FEPS sample from available broad-band
photometry and spectral types, and present an algorithm to normalize Kurucz
synthetic spectra to optical and near-infrared photometry. The final FEPS data
products include IRAC and MIPS photometry for each star in the FEPS sample and
calibrated IRS spectra.Comment: 64 pages, 12 figures, 5 tables; accepted for publication in ApJ
- …