128 research outputs found
Dietary treatment in Phenylketonuria does not lead to increased risk of obesity or metabolic syndrome
Evaluation of turbulent dissipation rate retrievals from Doppler Cloud Radar
Turbulent dissipation rate retrievals from cloud radar Doppler velocity measurements are evaluated using independent, in situ observations in Arctic stratocumulus clouds. In situ validation data sets of dissipation rate are derived using sonic anemometer measurements from a tethered balloon and high frequency pressure variation observations from a research aircraft, both flown in proximity to stationary, ground-based radars. Modest biases are found among the data sets in particularly low- or high-turbulence regimes, but in general the radar-retrieved values correspond well with the in situ measurements. Root mean square differences are typically a factor of 4-6 relative to any given magnitude of dissipation rate. These differences are no larger than those found when comparing dissipation rates computed from tetheredballoon and meteorological tower-mounted sonic anemometer measurements made at spatial distances of a few hundred meters. Temporal lag analyses suggest that approximately half of the observed differences are due to spatial sampling considerations, such that the anticipated radar-based retrieval uncertainty is on the order of a factor of 2-3. Moreover, radar retrievals are clearly able to capture the vertical dissipation rate structure observed by the in situ sensors, while offering substantially more information on the time variability of turbulence profiles. Together these evaluations indicate that radar-based retrievals can, at a minimum, be used to determine the vertical structure of turbulence in Arctic stratocumulus clouds
Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ∼ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures. [Figure not available: see fulltext.]
Efeito do tratamento térmico de lodo anaeróbio sobre as características de biodegradabilidade da fração orgânica
Near-intrinsic energy resolution for 30-662 keV gamma rays in a high pressure xenon electroluminescent TPC
We present the design, data and results from the NEXT prototype for Double Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural xenon electroluminescent time projection chamber (TPC) that was built at the Lawrence Berkeley National Laboratory. It is a prototype of the planned NEXT-100 136Xe neutrino-less double beta decay (0νββ) experiment with the main objectives of demonstrating near-intrinsic energy resolution at energies up to 662 keV and of optimizing the NEXT-100 detector design and operating parameters. Energy resolutions of ∼1% FWHM for 662 keV gamma rays were obtained at 10 and 15 atm and ∼5% FWHM for 30 keV fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions for the 2,459 keV hypothetical neutrino-less double beta decay peak are realizable. This energy resolution is a factor 7 to 20 better than that of the current leading 0νββ experiments using liquid xenon and thus represents a significant advancement. We present also first results from a track imaging system consisting of 64 silicon photo-multipliers recently installed in NEXT-DBDM that, along with the excellent energy resolution, demonstrates the key functionalities required for the NEXT-100 0νββ search
Componentes de produção e morfologia de raízes de mandioca sob diferentes preparos do solo
Results of the material screening program of the NEXT experiment
[EN] The Neutrino Experiment with a Xenon TPC (NEXT), intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium γ-ray spectrometry performed at the
Canfranc Underground Laboratory; recent results of this material screening program are presented here.Dafni, T.; Álvarez-Puerta, V.; Bandac, I.; Bettini, A.; Borges, FIGM.; Camargo, M.; Carcel, S.... (2016). Results of the material screening program of the NEXT experiment. Nuclear and Particle Physics Proceedings. 273-275:2666-2668. https://doi.org/10.1016/j.nuclphysbps.2015.10.024S26662668273-27
The NEXT White (NEW) detector
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation
An improved measurement of electron-ion recombination in high-pressure xenon gas
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100
high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration
source. Compared to our previous measurements with alpha particles, an upgraded detector and
improved analysis techniques have been used. We measure event-by-event correlated fluctuations
between ionization and scintillation due to electron-ion recombination in the gas, with correlation
coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the
two signals, we obtain a 2.8% FWHM energy resolution for 5.49 MeV alpha particles and a measurement
of the optical gain of the electroluminescent TPC. The improved energy resolution also
allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally,
we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be 0:561 0:045, translating into an average energy to produce a primary scintillation photon ofWex = (39:2 3:2) eV.This work was supported by the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.Serra, L.; Sorel, M.; Alvarez, V.; Borges, FIG.; Camargo, M.; Carcel, S.; Cebrian, S.... (2015). An improved measurement of electron-ion recombination in high-pressure xenon gas. Journal of Instrumentation. 10:1-19. https://doi.org/10.1088/1748-0221/10/03/P03025S1191
- …