175 research outputs found
A Structure–Conduct–Performance Perspective of How Strategic Supply Chain Integration Affects Firm Performance
There are several factors that affect a firm\u27s ability to successfully integrate internally and externally for organizational improvement. This study seeks to understand the relationship between a firm\u27s strategy, its supply chain integration efforts, and firm performance. Leveraging the theoretical lens of structure–conduct–performance from the industrial organization economics literature, and utilizing both archival and survey data, we describe how firms may align their internal and external supply chain integration strategies with customers and suppliers. In doing so, these internal and external integration strategies affect the firm\u27s ability to respond to customer demand, which then impacts operational and financial performance. Our work provides theoretical and empirical evidence of these relationships and thus extends prior strategic supply chain integration literature
A Comparison of Static Stretching Versus Combined Static and Ballistic Stretching in Active Knee Range of Motion
Background: There is continued controversy related to flexibility gains from different stretching protocols and within single protocols. Stretching methods include static, ballistic, dynamic, and proprioceptive neuromuscular facilitation (PNF). A combination of stretching methods may be an improved way to increase active knee range of motion (ROM). This study evaluated a single program formulated with static and ballistic components. Objective: To compare active knee ROM following stretching programs which either included combined static and ballistic stretching (CSBS) or static stretching (SS) alone. It was hypothesized that CSBS would show a greater increase in active knee ROM than SS. Setting: The pre- and post- measurements were performed in a laboratory. Subjects were randomly assigned to either treatment group or a non-stretching control group and given written instructions on how to perform their designated protocol at home. Subjects: Forty-three (33M, 10F) healthy collegiate aged participants (24.0 + 3.69 yrs, 176.21 + 10.0 cm, 78.15 + 12.93 kg) with no history of injury to the lower extremity or low back for the previous 6 months were eligible to participate in the study. Interventions: Two treatment groups either performed SS or CSBS for 30 seconds on each leg, twice a day for 2 weeks. All subjects but 3 provided both legs, and each leg was evaluated separately, providing 83 total measurements. Main Outcome Measures: A Johnson Digital Inclinometer was used to measure active knee extension. A mixed ANOVA with a Tukey post hoc test was used for statistical analysis. Results: There was no statistically significant difference in active knee ROM between groups at the pre-test, F(2,80)=1.062, p=.351, partial ƞ2=.026 (SS: 52.56 + 7.50º, CSBS: 49.84 + 8.91⁰, control: 49.39 + 10.09⁰). There was a statistically significant difference in active knee ROM between groups at the post-test, F(2,80)=29.034, p .05). There was homogeneity of covariance’s, as assessed by Box\u27s test of equality of covariance matrices (p = .076). There was homogeneity of variances, as assessed by Levene\u27s test of homogeneity of variance (p\u3e.05). Conclusions: SS and CSBS are equally effective for improving active knee ROM. A trend indicating CSBS showing only slightly greater differences may be due to limited time allowed to master the CSBS method, with no supervision during stretching sessions
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.Comment: 39 pages, 33 figures (33 EPS files), 12 tables. Planck LFI technical
papers published by JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/1748-022
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and
Astrophysic
Delivering energy efficiency and carbon reduction schemes in England: Lessons from Green Deal Pioneer Places
Against a background of growing international and national carbon reduction legislation, the UK government introduced the “Green Deal” to deliver a significant increase in housing energy efficiency and reduction in carbon emissions. This paper reflects on one English local authority's experience delivering a programme intended to foster local interest in the Green Deal. Drawing on social surveys and pre and post Green Deal intervention interviews with five demonstrator homes (households that applied to receive a Green Deal package fully funded by the scheme, providing a test bed for the Green Deal recruitment and installation process), this paper shows that awareness and understanding of the Green Deal scheme is low. There is opposition to the cost of finance offered but a strong interest in improving household warmth and for funding improvements through payments added to the electricity bill. Demonstrator home residents perceived Green Deals had improved the warmth and quality of their home, but saving money was the primary motivator for their involvement, not increasing warmth. Whilst Green Deal has not delivered the level of success that was hoped, much can be learned from the scheme to improve future energy efficiency schemes that will be necessary to deliver emission reduction commitments
The C-Band All-Sky Survey (C-BASS): design and implementation of the northern receiver
The C-Band All-Sky Survey is a project to map the full sky in total intensity and linear polarization at 5 GHz. The northern component of the survey uses a broad-band single-frequency analogue receiver fitted to a 6.1-m telescope at the Owens Valley Radio Observatory in California, USA. The receiver architecture combines a continuous-comparison radiometer and a correlation polarimeter in a single receiver for stable simultaneous measurement of both total intensity and linear polarization, using custom-designed analogue receiver components. The continuous-comparison radiometer measures the temperature difference between the sky and temperature-stabilized cold electrical reference loads. A cryogenic front-end is used to minimize receiver noise, with a system temperature of ≈30 K in both linear polarization and total intensity. Custom cryogenic notch filters are used to counteract man-made radio frequency interference. The radiometer 1/f noise is dominated by atmospheric fluctuations, while the polarimeter achieves a 1/f noise knee frequency of 10 mHz, similar to the telescope azimuthal scan frequency
- …