156 research outputs found
Recommended from our members
Cryptoendolith colonization of diverse substrates (1): cultivation and characterization
We are investigating whether cryptoendolithic microorganisms are able to colonize diverse substrates through biogenic weathering. This first part of the study involves the cultivation and characterization of microbial consortia from Antarctic sandstone habitats
Alcohol - foe or friend?
In the same month that this manuscript was prepared, newspapers had twice warned the public about the negative aspects of alcohol consumption. South African drinkers consume among the highest volumes of alcoholic beverages in the world, at approximately 50 ml ethanol per drinker per day, making alcohol abuse one of South Africa’s top ten health and social problems
Paraoxonase1 Genetic Polymorphisms in a Mixed Ancestry African Population
Paraoxonase 1 (PON1) activity is markedly influenced by coding polymorphisms, Q/R at position 192 and M/L at position 55 of the PON1 gene. We investigated the frequencies of these polymorphisms and their effects on PON1 and antioxidant activities in 844 South African mixed ancestry individuals. Genotyping was done using allele-specific TaqMan technology, PON1 activities were measured using paraoxon and phenylacetate, oxidative status was determined by measuring the antioxidant activities of ferric reducing antioxidant power and trolox equivalent antioxidant capacity, and lipid peroxidation markers included malondialdehyde and oxidized LDL. The frequencies of Q192R and L55M were 47.6% and 28.8%, respectively, and the most common corresponding alleles were 192R (60.4%) and 55M (82.6%). The Q192 was significantly associated with 5.8 units’ increase in PON1 concentration and 15.4 units’ decrease in PONase activity after adjustment for age, sex, BMI, and diabetes, with suggestion of differential effects by diabetes status. The PON1 L55 variant was associated with none of the measured indices. In conclusion, we have shown that the Q192R polymorphism is a determinant of both PON1 concentration and activity and this association appeared to be enhanced in subjects with diabetes
Prosthetic thigh arteriovenous access: outcome with SVS/AAVS reporting standards
AbstractPurposeDifferences in the reporting methods of results for arteriovenous (AV) access can dramatically affect apparent outcome. To enable meaningful comparisons in the literature, the Society for Vascular Surgery and the American Association for Vascular Surgery (SVS/AAVS) recently published reporting standards for dialysis access. The purpose of the present study was to determine infection rates, patency rates, and possible predictive factors for prosthetic thigh AV access outcomes with the reporting standards of the SVS/AAVS.MethodsA retrospective analysis was performed of all patients who underwent placement of thigh AV access by the Surgical Teaching Service at Greenville Memorial Hospital between 1989 and 2001. Outcomes were determined based on SVS/AAVS Standards for Reports Dealing with AV Accesses. The rate of revision per year of access patency was also determined; this end point more accurately reflects the true cost and morbidity associated with AV access than do patency or infection rates alone.ResultsOne hundred twenty-five polytetrafluoroethylene thigh AV accesses were placed in 100 patients. Nine accesses were excluded from the study, six because there was no patient follow-up and 3 as a result of deaths unrelated to the access procedure and which occurred less than 30 days after access placement. There were six (4%) late access-related deaths. There were 18 (15%) early access failures, related to infection in 14 cases (12%), thrombosis in three cases (2%), and steal in one case (1%). Early failure was more common in patients with diabetes mellitus (P = .036). The primary and secondary functional patency rates were 19% and 54%, respectively, at 2 years. Infection occurred in 48 (41%) accesses. The patency and infection rates were not influenced by patient age, gender, body mass index, or diabetes mellitus. The median number of interventions per year of access patency was 1.68, and this outcome was positively correlated with body mass index (P < .001).ConclusionsProsthetic AV access in the thigh is associated with higher morbidity compared with that reported for the upper extremity, and should be considered only if no upper extremity AV access option is available. Early access failure and the requirement for an increased number of interventions to reestablish and maintain access patency are more common in patients with diabetes mellitus and obesity. The number of interventions per year of access patency is a valuable end point when assessing the outcome of AV access procedures
Residual allergenicity of amino acid-based and extensively hydrolysed cow’s milk formulas
Background. Criteria for labelling infant feeds as suitable for the dietary management of cow’s milk protein allergy (CMPA) rely on proving the hypoallergenicity of such feeds or clinical studies showing that the feeds are tolerated by 90% of children with proven CMPA. South African (SA) labelling legislation does not indicate what testing is necessary to prove hypoallergenicity.Objectives. To evaluate all extensively hydrolysed cow’s milk formulas and amino acid-based formulas available in SA for residual allergen content, protein size and amino-acid content.Results. All amino-acid and extensively hydrolysed formulas were found to be similar in composition, with no residual cow’s milk allergens detectable by enzyme-linked immunosorbent assay. Furthermore, proteins were absent and only small molecules in the size range of amino acids and possibly of very small oligopeptides were detected.Conclusions. These findings indicate that the formulas are extremely likely to be compliant with the definition of hypoallergenicity as tolerance in 90% of proven sufferers from cow’s milk allergy. The formulas may therefore be labelled as suitable for the dietary management of infants with CMPA
Design, development and verification of the 30 and 44 GHz front-end modules for the Planck Low Frequency Instrument
We give a description of the design, construction and testing of the 30 and
44 GHz Front End Modules (FEMs) for the Low Frequency Instrument (LFI) of the
Planck mission to be launched in 2009. The scientific requirements of the
mission determine the performance parameters to be met by the FEMs, including
their linear polarization characteristics.
The FEM design is that of a differential pseudo-correlation radiometer in
which the signal from the sky is compared with a 4-K blackbody load. The Low
Noise Amplifier (LNA) at the heart of the FEM is based on indium phosphide High
Electron Mobility Transistors (HEMTs). The radiometer incorporates a novel
phase-switch design which gives excellent amplitude and phase match across the
band.
The noise temperature requirements are met within the measurement errors at
the two frequencies. For the most sensitive LNAs, the noise temperature at the
band centre is 3 and 5 times the quantum limit at 30 and 44 GHz respectively.
For some of the FEMs, the noise temperature is still falling as the ambient
temperature is reduced to 20 K. Stability tests of the FEMs, including a
measurement of the 1/f knee frequency, also meet mission requirements.
The 30 and 44 GHz FEMs have met or bettered the mission requirements in all
critical aspects. The most sensitive LNAs have reached new limits of noise
temperature for HEMTs at their band centres. The FEMs have well-defined linear
polarization characteristcs.Comment: 39 pages, 33 figures (33 EPS files), 12 tables. Planck LFI technical
papers published by JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/1748-022
Extensively hydrolysed infant formulas: Need for aligned definition of peptide size characteristics and standardisation of analytical methods
Letter by Nutten et al. on article by Levin et al. (Levin ME, Blackhurst DM, Kirstein F, Kok D, van der Watt GF, Marais AD. Residual allergenicity of amino acid-based and extensively hydrolysed cow’s milk formulas. S Afr Med J 2017;107(9):763-767. S Afr Med J 2017;107(3):258-263. https://doi.org/10.7196/SAMJ.2017.v107i9.12137); and response by Levin et al
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.Comment: 15 pages, 18 figures. Accepted for publication in Astronomy and
Astrophysic
First radial velocity results from the MINiature Exoplanet Radial Velocity Array (MINERVA)
The MINiature Exoplanet Radial Velocity Array (MINERVA) is a dedicated
observatory of four 0.7m robotic telescopes fiber-fed to a KiwiSpec
spectrograph. The MINERVA mission is to discover super-Earths in the habitable
zones of nearby stars. This can be accomplished with MINERVA's unique
combination of high precision and high cadence over long time periods. In this
work, we detail changes to the MINERVA facility that have occurred since our
previous paper. We then describe MINERVA's robotic control software, the
process by which we perform 1D spectral extraction, and our forward modeling
Doppler pipeline. In the process of improving our forward modeling procedure,
we found that our spectrograph's intrinsic instrumental profile is stable for
at least nine months. Because of that, we characterized our instrumental
profile with a time-independent, cubic spline function based on the profile in
the cross dispersion direction, with which we achieved a radial velocity
precision similar to using a conventional "sum-of-Gaussians" instrumental
profile: 1.8 m s over 1.5 months on the RV standard star HD 122064.
Therefore, we conclude that the instrumental profile need not be perfectly
accurate as long as it is stable. In addition, we observed 51 Peg and our
results are consistent with the literature, confirming our spectrograph and
Doppler pipeline are producing accurate and precise radial velocities.Comment: 22 pages, 9 figures, submitted to PASP, Peer-Reviewed and Accepte
- …