1,254 research outputs found
New Measurements of Fine-Scale CMB Polarization Power Spectra from CAPMAP at Both 40 and 90 GHz
We present new measurements of the cosmic microwave background (CMB)
polarization from the final season of the Cosmic Anisotropy Polarization MAPper
(CAPMAP). The data set was obtained in winter 2004-2005 with the 7 m antenna in
Crawford Hill, New Jersey, from 12 W-band (84-100 GHz) and 4 Q-band (36-45 GHz)
correlation polarimeters with 3.3' and 6.5' beamsizes, respectively. After
selection criteria were applied, 956 (939) hours of data survived for analysis
of W-band (Q-band) data. Two independent and complementary pipelines produced
results in excellent agreement with each other. A broad suite of null tests as
well as extensive simulations showed that systematic errors were minimal, and a
comparison of the W-band and Q-band sky maps revealed no contamination from
galactic foregrounds. We report the E-mode and B-mode power spectra in 7 bands
in the range 200 < l < 3000, extending the range of previous measurements to
higher l. The E-mode spectrum, which is detected at 11 sigma significance, is
in agreement with cosmological predictions and with previous work at other
frequencies and angular resolutions. The BB power spectrum provides one of the
best limits to date on B-mode power at 4.8 uK^2 (95% confidence).Comment: 19 pages, 17 figures, 2 tables, submitted to Ap
New plasmid calibrators for geminivirus-resistant (EMB-PV051-1 event) common bean (Phaseolus vulgaris L.) quantitation using simplex and duplex qPCR.
The geminivirus-resistant common bean, Embrapa 5.1, was the first commercial genetically modified (GM) event developed in Latin America by the Brazilian Agricultural Research Corp.. Therein novel standard reference plasmids were constructed for species-specific (pLEC) and event-specific (pFGM) qualitative and quantitative detection of Embrapa 5.1 GM common bean. To establish these plasmids as certified reference materials (CRM) for Embrapa 5.1 GM common bean, two DNA extraction protocols, simplex and duplex qPCR using two different operators (experimenters) were tested. The efficiency values ranged from 92% to 110% for the simplex and duplex reactions considering both operators. The limit of detection was enough to detect at least 0.1% GM content. These plasmids are suitable to be used as CRM for Embrapa 5.1 GM common bean. They will be useful for survey of food labels for compliance with legislation about GMO content in Brazil and in other countries where GM common bean is not yet approved for commercialization
Multiple testing issues in discriminating compound-related peaks and chromatograms from high frequency noise, spikes and solvent-based noise in LC-MS data sets
Screening, diagnosis and monitoring of sarcopenia:When to use which tool?
Background & aims: Sarcopenia is a muscle disorder associated with loss of muscle mass, strength and function. Early screening, diagnosis and treatment may improve outcome in different disease conditions. A wide variety of tools for estimation of muscle mass is available and each tool has specific technical requirements. However, different investigational settings and lack of homogeneity of populations influence the definition of gold standards, proving it difficult to systematically adopt these tools. Recently, the European Working Group on Sarcopenia in Older People (EWGSOP) published a revised recommendation (EWGSOP-2) and algorithm for using tools for screening and diagnosing sarcopenia. However, agreement of the EWGSOP2 criteria with other classifications is poor and although an overview of available tools is valuable, for the purpose of clinical decision-making the reverse is useful; a given scenario asks for the most suitable tools. Results: Tools were identified for screening, diagnostics and longitudinal monitoring of muscle mass. For each of these clinical scenarios the most appropriate tools were listed and for each technique their usability is specified based on sensitivity and specificity. Based on this information a specific recommendation is made for each clinical scenario. Conclusion: This narrative review provides an overview of currently available tools and future developments for different clinical scenarios such as screening, diagnosis and longitudinal monitoring of alterations in muscle status. It supports clinical decision-making in choosing the right tools for muscle mass quantification depending on the need within a given clinical scenario as well as the local availability and expertise. (C) 2022 The Author(s). Published by Elsevier Ltd on behalf of European Society for Clinical Nutrition and Metabolism
The QUIET Instrument
The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the
Cosmic Microwave Background, targeting the imprint of inflationary
gravitational waves at large angular scales (~ 1 degree). Between 2008 October
and 2010 December, two independent receiver arrays were deployed sequentially
on a 1.4 m side-fed Dragonian telescope. The polarimeters which form the focal
planes use a highly compact design based on High Electron Mobility Transistors
(HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U,
and I in a single module. The 17-element Q-band polarimeter array, with a
central frequency of 43.1 GHz, has the best sensitivity (69 uK sqrt(s)) and the
lowest instrumental systematic errors ever achieved in this band, contributing
to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter
array has a sensitivity of 87 uK sqrt(s) at a central frequency of 94.5 GHz. It
has the lowest systematic errors to date, contributing at r < 0.01. The two
arrays together cover multipoles in the range l= 25-975. These are the largest
HEMT-based arrays deployed to date. This article describes the design,
calibration, performance of, and sources of systematic error for the
instrument
QUaD: A High-Resolution Cosmic Microwave Background Polarimeter
We describe the QUaD experiment, a millimeter-wavelength polarimeter designed
to observe the Cosmic Microwave Background (CMB) from a site at the South Pole.
The experiment comprises a 2.64 m Cassegrain telescope equipped with a
cryogenically cooled receiver containing an array of 62 polarization-sensitive
bolometers. The focal plane contains pixels at two different frequency bands,
100 GHz and 150 GHz, with angular resolutions of 5 arcmin and 3.5 arcmin,
respectively. The high angular resolution allows observation of CMB temperature
and polarization anisotropies over a wide range of scales. The instrument
commenced operation in early 2005 and collected science data during three
successive Austral winter seasons of observation.Comment: 23 pages, author list and text updated to reflect published versio
First Season QUIET Observations: Measurements of CMB Polarization Power Spectra at 43 GHz in the Multipole Range 25 <= ell <= 475
The Q/U Imaging ExperimenT (QUIET) employs coherent receivers at 43GHz and
95GHz, operating on the Chajnantor plateau in the Atacama Desert in Chile, to
measure the anisotropy in the polarization of the CMB. QUIET primarily targets
the B modes from primordial gravitational waves. The combination of these
frequencies gives sensitivity to foreground contributions from diffuse Galactic
synchrotron radiation. Between 2008 October and 2010 December, >10,000hours of
data were collected, first with the 19-element 43GHz array (3458hours) and then
with the 90-element 95GHz array. Each array observes the same four fields,
selected for low foregrounds, together covering ~1000deg^2. This paper reports
initial results from the 43GHz receiver which has an array sensitivity to CMB
fluctuations of 69uK sqrt(s). The data were extensively studied with a large
suite of null tests before the power spectra, determined with two independent
pipelines, were examined. Analysis choices, including data selection, were
modified until the null tests passed. Cross correlating maps with different
telescope pointings is used to eliminate a bias. This paper reports the EE, BB
and EB power spectra in the multipole range ell=25-475. With the exception of
the lowest multipole bin for one of the fields, where a polarized foreground,
consistent with Galactic synchrotron radiation, is detected with 3sigma
significance, the E-mode spectrum is consistent with the LCDM model, confirming
the only previous detection of the first acoustic peak. The B-mode spectrum is
consistent with zero, leading to a measurement of the tensor-to-scalar ratio of
r=0.35+1.06-0.87. The combination of a new time-stream double-demodulation
technique, Mizuguchi-Dragone optics, natural sky rotation, and frequent
boresight rotation leads to the lowest level of systematic contamination in the
B-mode power so far reported, below the level of r=0.1Comment: 19 pages, 14 figures, higher quality figures are available at
http://quiet.uchicago.edu/results/index.html; Fixed a typo and corrected
statistical error values used as a reference in Figure 14, showing our
systematic uncertainties (unchanged) vs. multipole; Revision to ApJ accepted
version, this paper should be cited as "QUIET Collaboration et al. (2011)
Constraining the source regions of lunar meteorites using orbital geochemical data
Lunar meteorites provide important new samples of the Moon remote from regions visited by the Apollo and Luna sample return missions. Petrologic and geochemical analysis of these meteorites, combined with orbital remote-sensing measurements have enabled additional discoveries about the composition and age of the lunar surface on a global scale. However, the interpretation of these samples is limited by the fact that we do not know the source region of any individual lunar meteorite. Here we investigate the link between meteorite and source region on the Moon using the Lunar Prospector Gamma Ray Spectrometer remote sensing dataset for the elements Fe, Ti and Th. The approach has been validated using Apollo and Luna bulk regolith samples and we have applied it to 48 meteorites excluding paired stones. Our approach is able broadly to differentiate the best compositional matches as potential regions of origin for the various classes of lunar meteorites. Basaltic and intermediate-Fe regolith breccia meteorites are found to have the best constrained potential launch sites, with some impact breccias and pristine mare basalts also having reasonably well defined potential source regions. Launch areas for highland feldspathic meteorites are much less well constrained and the addition of another element, such as Mg, will probably be required to identify potential source regions for these
Whole Earth Telescope observations of the hot helium atmosphere pulsating white dwarf EC 20058-5234
We present the analysis of a total of 177h of high-quality optical
time-series photometry of the helium atmosphere pulsating white dwarf (DBV) EC
20058-5234. The bulk of the observations (135h) were obtained during a WET
campaign (XCOV15) in July 1997 that featured coordinated observing from 4
southern observatory sites over an 8-day period. The remaining data (42h) were
obtained in June 2004 at Mt John Observatory in NZ over a one-week observing
period. This work significantly extends the discovery observations of this
low-amplitude (few percent) pulsator by increasing the number of detected
frequencies from 8 to 18, and employs a simulation procedure to confirm the
reality of these frequencies to a high level of significance (1 in 1000). The
nature of the observed pulsation spectrum precludes identification of unique
pulsation mode properties using any clearly discernable trends. However, we
have used a global modelling procedure employing genetic algorithm techniques
to identify the n, l values of 8 pulsation modes, and thereby obtain
asteroseismic measurements of several model parameters, including the stellar
mass (0.55 M_sun) and T_eff (~28200 K). These values are consistent with those
derived from published spectral fitting: T_eff ~ 28400 K and log g ~ 7.86. We
also present persuasive evidence from apparent rotational mode splitting for
two of the modes that indicates this compact object is a relatively rapid
rotator with a period of 2h. In direct analogy with the corresponding
properties of the hydrogen (DAV) atmosphere pulsators, the stable low-amplitude
pulsation behaviour of EC 20058 is entirely consistent with its inferred
effective temperature, which indicates it is close to the blue edge of the DBV
instability strip. (abridged)Comment: 19 pages, 8 figures, 5 tables, MNRAS accepte
- …