37 research outputs found
Electrophysiological ON and OFF responses in autosomal dominant optic atrophy
Purpose To assess the effect of ADOA on the ON and OFF components of the photopic negative response (PhNR). Methods Twelve participants from 6 families with OPA1 ADOA and 16 age matched controls were recruited. Electrophysiological assessment involved long flash focal (20o) and full field ERGs using red flash (664 nm, 250 msec, 55 cd/m2, 2 Hz) on a rod saturating blue background (454 nm, 100 scot cd/m2); and brief xenon flash ERGs using red filter (Lee Filter “Terry Red”, max 300 µs flash duration, 1.69 cd.s.m-2, 4 Hz) over a continuous rod saturating blue background (Schott Glass Filter BG28, 206 scot cd/m2). Amplitudes (from peak and baseline to fixed time point) and implicit times of the ERG components were analysed. Results Mean amplitude (peak to fixed time) of the focal PhNR-ON were significantly (p < 0.05) reduced by 40% while the focal PhNR-OFF was completely eliminated. In the long duration full field ERG, the PhNR-ON and –OFF were reduced by 21% and 57% respectively. Subtraction of the grand averaged ERG of ADOA participants from that of the controls produced a difference plot with a nearly symmetrical loss in the PhNR-ON and OFF components of the focal ERG. ROC curve analysis showed focal PhNR-ON and OFF amplitudes performed better than their full field counterparts. Conclusions We show that OFF components of the photopic ERG were more severely affected in ADOA than ON components. Additionally, the focal PhNR-ON and –OFF components were more effective in assessing ADOA than their full field components
Recommended from our members
The effect of bleach duration and age on the ERG photostress test
Background: The ERG photostress test assesses the recovery of the focal 41 Hz ERG following exposure to a bright light that bleaches a significant proportion of photopigment. The aims of this study were: 1) to compare the repeatability of the ERG photostress test recovery time constant following long and short duration light exposure, and 2) to determine the effect of age on the ERG photostress test recovery time constant.
Methods: Focal 41 Hz ERGs were recorded from 23 participants (age range 20–71 years) at 20-second intervals for 5 minutes following either a short-duration (photoflash) or long-duration (equilibrium) light exposure. After a 5-minute wash-out period, the procedure was repeated using the second bleach modality. The time constant of cone recovery was determined by fitting an exponential model to the amplitude recovery data. The whole procedure was repeated on a second occasion. The co-efficient of repeatability (CoR) was calculated for each bleaching technique. The relationship between the time constant of recovery and age was investigated (Pearson’s correlation coefficient).
Results: The time constant of recovery following an equilibrium bleach was more repeatable than recovery following a photoflash (CoR = 85s and 184s respectively). Eight trials (from seven participants) failed to show a reduction in amplitude following the photoflash, suggesting that a blink or fixation loss had occurred. All participants were reliably light-adapted by the equilibrium bleach. For the equilibrium bleach data, the time constant of recovery increased with age at a rate of 27 seconds per decade.
Conclusions: The equilibrium bleach was more reliable and repeatable than the photoflash. Increasing participant age was shown to result in a lengthening of the recovery time constant, of a magnitude comparable to previously published psychophysical data
Functional Imaging of the Outer Retinal Complex using High Fidelity Imaging Retinal Densitometry
We describe a new technique, high fdelity Imaging Retinal Densitometry (IRD), which probes the
functional integrity of the outer retinal complex. We demonstrate the ability of the technique to
map visual pigment optical density and synthesis rates in eyes with and without macular disease. A
multispectral retinal imaging device obtained precise measurements of retinal refectance over space
and time. Data obtained from healthy controls and 5 patients with intermediate AMD, before and after
photopigment bleaching, were used to quantify visual pigment metrics. Heat maps were plotted to
summarise the topography of rod and cone pigment kinetics and descriptive statistics conducted to
highlight diferences between those with and without AMD. Rod and cone visual pigment synthesis
rates in those with AMD (v=0.043SD 0.019min−1 and v=0.119SD 0.046min−1, respectively)
were approximately half those observed in healthy controls (v=0.079SD 0.024min−1 for rods and
v=0.206SD 0.069min−1 for cones). By mapping visual pigment kinetics across the central retina,
high fdelity IRD provides a unique insight into outer retinal complex function. This new technique
will improve the phenotypic characterisation, diagnosis and treatment monitoring of various ocular
pathologies, including AMD
Test-Retest Variability and Discriminatory Power of Measurements From Microperimetry and Dark Adaptation Assessment in People With Intermediate Age-Related Macular Degeneration – A MACUSTAR Study Report
Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx. //
Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (±7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD. //
Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test-retest variability in iAMD (95% confidence interval [CI] ICC of 0.79–0.89 and 0.78–0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55–0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. //
Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls. //
Translational Relevance: Expected levels of test-retest variability and discriminatory power of the AdaptDx and MAIA devices in a clinical study setting must be considered when designing future trials for people with AMD
Recommended from our members
Detection of early age-related macular degeneration using novel functional parameters of the focal cone electroretinogram
The focal cone electroretinogram is a sensitive marker for macular disease, but have we unlocked its full potential? Typically assessment of waveform parameters is subjective and focuses on a small number of locations (e.g. the a-wave). This study evaluated the discriminatory and diagnostic potential of 4 conventional and 15 novel, objectively determined, parameters in patients with early Age-related Macular Degeneration. Focal cone electroretinograms were recorded in 54 participants with early Age-related Macular Degeneration (72.9±8.2 years) and 54 healthy controls (69±7.7 years). Conventional a and b wave amplitudes and implicit times were measured and compared to novel parameters derived from both the 1st and 2nd derivatives and the frequency-domain power spectrum of the electroretinogram.Statistically significant differences between groups were shown for all conventional parameters, the majority of 1st and 2nd derivative parameters and the power spectrum at 25 and 30 Hz. Receiver operating characteristics showed that both conventional and 1st and 2nd derivative implicit times had provided the best diagnostic potential. A regression model showed a small improvement over any individual parameter investigated. The non-conventional parameters enhanced the objective evaluation of the focal electroretinogram, especially when the amplitude was low. Furthermore, the novel parameters described here allow the implicit time of the electroretinogram to be probed at points other than the peaks of the a and b waves. Consequently these novel analysis techniques could prove valuable in future electrophysiological investigation, detection and monitoring of Age-related Macular Degeneration
Benefits, Barriers and Enablers of Breastfeeding: Factor Analysis of Population Perceptions in Western Australia
Objective: The objective of this study was to investigate knowledge and community perceptions of breastfeeding in Western Australia using a factor analysis approach. Methods: Data were pooled from five Nutrition Monitoring Survey Series which included information on breastfeeding from 4,802 Western Australian adults aged 18–64 years. Tetrachoric factor analysis was conducted for data reduction and significant associations identified using logistic, ordinal and poisson regression analyses. Results: Four factors were derived for benefits (it’s natural, good nutrition, good for the baby, and convenience), barriers (breastfeeding problems, poor community acceptability, having to go back to work, and inconvenience) and for enablers (breastfeeding education, community support, family support and not having to work).As assessed by standardized odds ratios the most important covariates across benefit factors were: importance of breastfeeding (ORs range from 1.22–1.44),female gender (ORs range from 0.80 to 1.46), being able to give a time for how long a baby should be breastfed (ORs range from 0.96 to 1.27) and education (less than high school to university completion) (ORs range from 0.95 to 1.23); the most important covariate across barrier factors was being able to give a time for how long a baby should be breastfed (ORs range from 0.89 to 1.93); and the most important covariates across all enabling factors were education (ORs range from 1.14 to1.32) and being able to give a time for how long a baby should be breastfed (ORs range from 1.17 to 1.42).Conclusions: Being female, rating breastfeeding as important, believing that babies should be breastfed for a period of time and education accounted for most of the statistically significant associations. The differences between male and female perceptions require investigation particularly in relation to returning to work
Recommended from our members
Effect of varying skin surface electrode position on electroretinogram responses recorded using a handheld stimulating and recording system
Purpose
A handheld device (the RETeval system, LKC Technologies) aims to increase the ease of electroretinogram (ERG) recording by using specially designed skin electrodes, rather than corneal electrodes. We explored effects of electrode position on response parameters recorded using this device.
Methods
Healthy adult twins were recruited from the TwinsUK cohort and underwent recording of light-adapted flicker ERGs (corresponding to international standard stimuli). In Group 1, skin electrodes were placed in a “comfortable” position, which was up to 20 mm below the lid margin. For subsequent participants (Group 2), the electrode was positioned 2 mm from the lid margin as recommended by the manufacturer. Amplitudes and peak times (averaged from both eyes) were compared between groups after age-matching and inclusion of only one twin per pair. Light-adapted flicker and flash ERGs were recorded for an additional 10 healthy subjects in two consecutive recording sessions: in the test eye, electrode position was varied from 2 to 10–20 mm below the lid margin between sessions; in the fellow (control) eye, the electrode was 2 mm below the lid margin throughout. Amplitudes and peak times (test eye normalised to control eye) were compared for the two sessions.
Results
Including one twin per pair, and age-matching yielded 28 individuals per group. Flicker ERG amplitudes were significantly lower for Group 1 than Group 2 participants (p = 0.0024). However, mean peak times did not differ between groups (p = 0.54). For the subjects in whom electrode position was changed between recording sessions, flash and flicker amplitudes were significantly lower when positioned further from the lid margin (p 0.5).
Conclusions
Moving the skin electrodes further from the lid margin significantly reduces response amplitudes, highlighting the importance of consistent electrode positioning. However, this does not significantly affect peak times. Thus, it may be feasible to adopt a more comfortable position in participants who cannot tolerate the recommended position if analysis is restricted to peak time parameters
Recommended from our members
Effect of rehabilitation worker input on visual function outcomes in individuals with low vision: study protocol for a randomised controlled trial
BACKGROUND: Visual Rehabilitation Officers help people with a visual impairment maintain their independence. This intervention adopts a flexible, goal-centred approach, which may include training in mobility, use of optical and non-optical aids, and performance of activities of daily living. Although Visual Rehabilitation Officers are an integral part of the low vision service in the United Kingdom, evidence that they are effective is lacking. The purpose of this exploratory trial is to estimate the impact of a Visual Rehabilitation Officer on self-reported visual function, psychosocial and quality-of-life outcomes in individuals with low vision.
METHODS/DESIGN: In this exploratory, assessor-masked, parallel group, randomised controlled trial, participants will be allocated either to receive home visits from a Visual Rehabilitation Officer (n = 30) or to a waiting list control group (n = 30) in a 1:1 ratio. Adult volunteers with a visual impairment, who have been identified as needing rehabilitation officer input by a social worker, will take part. Those with an urgent need for a Visual Rehabilitation Officer or who have a cognitive impairment will be excluded. The primary outcome measure will be self-reported visual function (48-item Veterans Affairs Low Vision Visual Functioning Questionnaire). Secondary outcome measures will include psychological and quality-of-life metrics: the Patient Health Questionnaire (PHQ-9), the Warwick-Edinburgh Mental Well-being Scale (WEMWBS), the Adjustment to Age-related Visual Loss Scale (AVL-12), the Standardised Health-related Quality of Life Questionnaire (EQ-5D) and the UCLA Loneliness Scale. The interviewer collecting the outcomes will be masked to the group allocations. The analysis will be undertaken on a complete case and intention-to-treat basis. Analysis of covariance (ANCOVA) will be applied to follow-up questionnaire scores, with the baseline score as a covariate.
DISCUSSION: This trial is expected to provide robust effect size estimates of the intervention effect. The data will be used to design a large-scale randomised controlled trial to evaluate fully the Visual Rehabilitation Officer intervention. A rigorous evaluation of Rehabilitation Officer input is vital to direct a future low vision rehabilitation strategy and to help direct government resources.
TRIAL REGISTRATION: The trial was registered with ( ISRCTN44807874 ) on 9 March 2015
Recommended from our members
How effective is low vision service provision? A systematic review
Visual impairment is a large and growing socioeconomic problem. Good evidence on rehabilitation outcomes is required to guide service development and improve the lives of people with sight loss. Of the 478 potentially relevant articles identified, only 58 studies met our liberal inclusion criteria, and of these only 7 were randomized controlled trials. Although the literature is sufficient to confirm that rehabilitation services result in improved clinical and functional ability outcomes, the effects on mood, vision-related quality of life (QoL) and health-related QoL are less clear. There are some good data on the performance of particular types of intervention, but almost no useful data about outcomes in children, those of working age, and other groups. There were no reports on cost effectiveness. Overall, the number of well-designed and adequately reported studies is pitifully small; visual rehabilitation research needs higher quality research. We highlight study design and reporting considerations and suggest a future research agenda