73 research outputs found

    The relationship between workload and exercise-induced cardiac troponin elevations is influenced by non-obstructive coronary atherosclerosis

    Get PDF
    The relationship between exercise-induced troponin elevation and non-obstructive coronary artery disease (CAD) is unclear. This observational study assessed non-obstructive CAD's impact on exercise-induced cardiac Troponin I (cTnI) elevation in middle-aged recreational athletes. cTnI levels of 40 well-trained recreational athletes (73% males, 50 ± 9 years old) were assessed by a high-sensitive cTnI assay 24 h before, and at 3 and 24 h following two high-intensity exercises of different durations; a cardiopulmonary exercise test (CPET), and a 91-km mountain bike race. Workload was measured with power meters. Coronary computed tomography angiography was used to determine the presence or absence of non-obstructive (<50% obstruction) CAD. A total of 15 individuals had non-obstructive CAD (Atherosclerotic group), whereas 25 had no atherosclerosis (normal). There were higher post-exercise cTnI levels following the race compared with CPET, both at 3 h (77.0 (35.3–112.4) ng/L vs. 11.6 (6.4–22.5) ng/L, p < 0.001) and at 24 h (14.7 (6.7–16.3) vs. 5.0 (2.6–8.9) ng/L, p < 0.001). Absolute cTnI values did not differ among groups. Still, the association of cTnI response to power output was significantly stronger in the CAD versus Normal group both at 3 h post-exercise (Rho = 0.80, p < 0.001 vs. Rho = −0.20, p = 0.33) and 24-h post-exercise (Rho = 0.87, p < 0.001 vs. Rho = −0.13, p = 0.55). Exercise-induced cTnI elevation was strongly correlated with exercise workload in middle-aged athletes with non-obstructive CAD but not in individuals without CAD. This finding suggests that CAD influences the relationship between exercise workload and the cTnI response even without coronary artery obstruction.publishedVersio

    Using systems thinking and open innovation to strengthen aquaculture policy for the United Nations Sustainable Development Goals

    Get PDF
    In a world of nine billion people and a widening income gap between the rich and poor, it is time to rethink how aquaculture can strengthen its contribution to the second UN Sustainable Development Goal (SDG) of zero hunger in our generation. The disparity in the level of sustainable aquaculture development at present, between and within countries, especially regarding human access to farmed aquatic food remains highly variable across the globe. This paper offers a fresh look at the opportunities from using systems thinking and new open innovation measuring tools to grow sustainable aquaculture. Political will in many nations is the main constraint to aquaculture in realising its potential as an: accessible source of micronutrients and nutritious protein; aid to meeting conservation goals; economic prosperity generator where benefits extend to locals and provider of indirect social benefits such as access to education and well‐being, among others. Resources to enable strong partnerships (SDG 17) between academia, civic society, government and industry should be prioritised by governments to build a sustainable aquatic food system, accessible to all, forever

    Hemocompatibility of Silicon-Based Substrates for Biomedical Implant Applications

    Get PDF
    Silicon membranes with highly uniform nanopore sizes fabricated using microelectromechanical systems (MEMS) technology allow for the development of miniaturized implants such as those needed for renal replacement therapies. However, the blood compatibility of silicon has thus far been an unresolved issue in the use of these substrates in implantable biomedical devices. We report the results of hemocompatibility studies using bare silicon, polysilicon, and modified silicon substrates. The surface modifications tested have been shown to reduce protein and/or platelet adhesion, thus potentially improving biocompatibility of silicon. Hemocompatibility was evaluated under four categories—coagulation (thrombin–antithrombin complex, TAT generation), complement activation (complement protein, C3a production), platelet activation (P-selectin, CD62P expression), and platelet adhesion. Our tests revealed that all silicon substrates display low coagulation and complement activation, comparable to that of Teflon and stainless steel, two materials commonly used in medical implants, and significantly lower than that of diethylaminoethyl (DEAE) cellulose, a polymer used in dialysis membranes. Unmodified silicon and polysilicon showed significant platelet attachment; however, the surface modifications on silicon reduced platelet adhesion and activation to levels comparable to that on Teflon. These results suggest that surface-modified silicon substrates are viable for the development of miniaturized renal replacement systems

    Functional Annotation of All Salmonid Genomes (FAASG): an international initiative supporting future salmonid research, conservation and aquaculture

    Get PDF
    We describe an emerging initiative - the 'Functional Annotation of All Salmonid Genomes' (FAASG), which will leverage the extensive trait diversity that has evolved since a whole genome duplication event in the salmonid ancestor, to develop an integrative understanding of the functional genomic basis of phenotypic variation. The outcomes of FAASG will have diverse applications, ranging from improved understanding of genome evolution, to improving the efficiency and sustainability of aquaculture production, supporting the future of fundamental and applied research in an iconic fish lineage of major societal importance

    Determinants of interindividual variation in exercise-induced cardiac troponin i levels

    Get PDF
    Background Postexercise cardiac troponin levels show considerable interindividual variations. This study aimed to identify the major determinants of this postexercise variation in cardiac troponin I (cTnI) following 3 episodes of prolonged high‐intensity endurance exercise. Methods and Results Study subjects were recruited among prior participants in a study of recreational cyclists completing a 91‐km mountain bike race in either 2013 or 2014 (first race). In 2018, study participants completed a cardiopulmonary exercise test 2 to 3 weeks before renewed participation in the same race (second race). Blood was sampled before and at 3 and 24 hours following all exercises. Blood samples were analyzed using the same Abbot high‐sensitivity cTnI STAT assay. Fifty‐nine individuals (aged 50±9 years, 13 women) without cardiovascular disease were included. Troponin values were lowest before, highest at 3 hours, and declining at 24 hours. The largest cTnI difference was at 3 hours following exercise between the most (first race) (cTnI: 200 [87–300] ng/L) and the least strenuous exercise (cardiopulmonary exercise test) (cTnI: 12 [7–23] ng/L; P<0.001). The strongest correlation between troponin values at corresponding times was before exercise (r=0.92, P<0.0001). The strongest correlations at 3 hours were between the 2 races (r=0.72, P<0.001) and at 24 hours between the cardiopulmonary exercise test and the second race (r=0.83, P<0.001). Participants with the highest or lowest cTnI levels showed no differences in race performance or baseline echocardiographic parameters. Conclusions The variation in exercise‐induced cTnI elevation is largely determined by a unique individual cTnI response that is dependent on the duration of high‐intensity exercise and the timing of cTnI sampling.publishedVersio
    corecore