452 research outputs found

    80-Gb/s OTDM system analysis of a vertical microcavity-based saturable absorber for the enhancement of pulse pedestal suppression

    Get PDF
    In future high-speed optical time-division-multiplexed (OTDM) systems, an important factor that needs to be considered for optical pulse generation schemes is the impact of pulse pedestals on the overall system performance. The results presented in this letter are two-fold; first, the impact due to the height of pulse pedestals in an 80-Gb/s OTDM system are established. Second, a solution is provided to overcome these high pedestal levels through the use of a vertical microcavity saturable absorber, which can significantly reduce the pulse pedestal level and give enhanced system performanc

    Sliding mode control of spatial mechanical systems decoupling translation and rotation

    Get PDF
    This paper looks at the robust trajectory control of spatial mechanical systems using sliding mode techniques. Two distinctions of the proposed method from reported methods are: (1) The measure of attitudinal error used is intrinsically defined, Euclidean-geometric, and intuitive. From Euler's theorem it follows that given a desired and actual attitude of a rigid body there exists an axis and angle of rotation relating the two attitudes. This defines a relative rotation vector, which is used as an intrinsically defined, intuitive measure of error. Reported methods use algebraic differences of entities such as generalized coordinates representing attitude. While functionally correlated to attitudinal error, these measures are not intrinsically defined. (2) A novel, dynamically nonlinear sliding function is used that results in a simple control law. The parameters of this function are dynamically and geometrically intuitive. Simulation results are given for a spacecraft tracking a complex desired trajectory

    Reduction of three-band model for copper oxides to single-band generalized t~-~J model

    Full text link
    A three-band model for copper oxides in the region of parameters where the second hole on the copper has energy close to the first hole on the oxygen is considered. The exact solution for one hole on a ferromagnetic background of the ordered copper spins is obtained. A general procedure for transformation of the primary Hamiltonian to the Hamiltonian of singlet and triplet excitations is proposed. Reduction of the singlet-triplet Hamiltonian to the single-band Hamiltonian of the generalized t~-~J model is performed. A comparison of the solution for the generalized t~-~J model on a ferromagnetic background with the exact solution shows a very good agreement.Comment: 20 pages (LATEX

    The anatomy of the fruit in relation to the propensity of citrus species to split

    Get PDF
    The anatomy of the fruit has been compared in three prone-to-split mandarin hybrids (Nova, Ellendale and Murcott), several cultivars of clementine mandarin (Fino, Clementina de Nules and Orogrande), and in Owari satsuma mandarin. The fruit of the hybrids is oblate to subglobose and usually presents an open stylar end disrupted by a navel formed by the floral meristem, which is conserved near the apex of the fruit. In the non-prone-to-split clementines as well as in Owari satsuma, the floral axis protrudes inside the style, and the flower meristem is lost through abscission shortly after petal fall. The abaxial side of the carpels fuses with the flower axis forming at the stylar end of the fruit a solid tissue which externally has a small scar at the place of style abscission. Most of the fruits in these cultivars have no navel. In addition, the fruit of clementine is slightly oblate or globose. The relevance of these anatomical characteristics as regards to splitting is supported by the differences between the split and non-split fruits in Nova, the split fruit being more oblate in shape and having a bigger navel than non-split fruit. However, the effect of applied growth regulators on fruit splitting could not be correlated with their effect on the anatomy of the fruit. Additional factors not contemplated in the study also influence fruit splitting

    Compton Scattering and the Spin Structure of the Nucleon at Low Energies

    Get PDF
    We analyze polarized Compton scattering which provides information on the spin-structure of the nucleon. For scattering processes with photon energies up to 100 MeV the spin-structure dependence can be encoded into four independent parameters-the so-called spin-polarizabilities γi,i=1...4\gamma_i, i=1...4 of the nucleon, which we calculate within the framework of the "small scale expansion" in SU(2) baryon chiral perturbation theory. Specific application is made to "forward" and "backward" spin- polarizabilities.Comment: 8 pages revtex file, separation between pion-pole and regular contributions detailed + minor wording changes, results and conclusions unchange

    K_S\rightarrow \gamma\gamma , K_L\rightarrow\pi^0\gamma\gamma$ and Unitarity

    Full text link
    Agreement between the experimental value Γ(KSγγ)\Gamma (K_S\rightarrow \gamma\gamma) and the number predicted via a one-loop chiral perturbation theory calculation has been cited as a success for the latter. On the other hand the one-loop prediction for the closely related process KLπ0γγK_L\rightarrow \pi^0\gamma\gamma has been found to be a factor three below the experimental value. Using the inputs of unitarity and dispersion relations, we demonstrate the importance of higher order loop effects to both of these processes.Comment: 20 pages (4 figures available on request), UMHEP-39

    Development of multilayer Hydroxyapatite - Ag/TiN-Ti coatings deposited by radio frequency magnetron sputtering with potential application in the biomedical field

    Full text link
    "NOTICE: this is the author's version of a work that was accepted for publication in Surface and Coatings Technology. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Surface and Coatings Technology, VOL 377, (2019) DOI 10.1016/j.surfcoat.2019.06.097"[EN] The use of composite coatings is emerging as a great alternative to conventional coatings, allowing the combination of different superficial properties that are widely desired in surgical implants, such as osteointegration and bactericidal character, and cannot be provided by one material alone. In the present investigation the effect of the incorporation of a TiN-Ti intermediate bilayer on the chemical composition, structure, morphology, roughness, residual stresses and adhesion of a multi-layer Hydroxyapatite (HA)-Ag coating deposited on Ti-6Al-4V by magnetron sputtering was evaluated. Additionally, the cytotoxicity of the developed system was evaluated by in vitro tests. According to the results obtained, a decrease in the Ca/P ratio from 1.85 to 1.74 was obtained through the deposition of an HA-Ag system on the intermediate bilayer, and the crystallinity of the developed coating was favored. The multi-layer structure was effectively observed by field emission scanning electron microscopy, where it was possible to identify each of the HA, Ag, TiN and Ti layers. Meanwhile, an increase of 7% in crystallite size, a decrease of 36% in residual stresses and an increase of 32% in adhesion were registered for this composite coating compared to the free intermediate bilayer system. Finally, biological evaluation allowed the non-cytotoxic character of the deposited coatings to be confirmed.We thank the University of Antioquia, the Centro de Investigation, Innovation y Desarrollo de materiales (CIDEMAT) group, the Departamento Administrativo de Ciencia, Tecnologia e Innovation (COLCIENCIAS) for financing the Project 15-1696, the scholarship program of Enlazamundos, PR and JLGR acknowledge financial support from the Spanish Ministry of Economy and Competitiveness (MINECO) through the project MAT2016-76039-C4-1-R (AEI/FEDER, UE) (including the FEDER financial support). CIBER-BBN is an initiative funded by the VI National R&D&I Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER Actions are financed by the Institute de Salud Carlos III with assistance from the European Regional Development Fund.Lenis, J.; Bejarano, G.; Rico Tortosa, PM.; Gómez Ribelles, JL.; Bolívar, F. (2019). Development of multilayer Hydroxyapatite - Ag/TiN-Ti coatings deposited by radio frequency magnetron sputtering with potential application in the biomedical field. Surface and Coatings Technology. 377:1-9. https://doi.org/10.1016/j.surfcoat.2019.06.097S19377Melero, H., Fernández, J., & Guilemany Casadamon, J. M. (2011). Recubrimientos bioactivos: Hidroxiapatita y titania. Biomecánica, 19(1). doi:10.5821/sibb.v19i1.1814Ozeki, K., Yuhta, T., Fukui, Y., & Aoki, H. (2002). Phase composition of sputtered films from a hydroxyapatite target. Surface and Coatings Technology, 160(1), 54-61. doi:10.1016/s0257-8972(02)00363-8Nelea, V., Morosanu, C., Iliescu, M., & Mihailescu, I. N. (2003). Microstructure and mechanical properties of hydroxyapatite thin films grown by RF magnetron sputtering. Surface and Coatings Technology, 173(2-3), 315-322. doi:10.1016/s0257-8972(03)00729-1Mohseni, E., Zalnezhad, E., Bushroa, A. R., Abdel Magid Hamouda, Goh, B. T., & Yoon, G. H. (2015). Ti/TiN/HA coating on Ti–6Al–4V for biomedical applications. Ceramics International, 41(10), 14447-14457. doi:10.1016/j.ceramint.2015.07.081Nelea, V., Morosanu, C., Bercu, M., & Mihailescu, I. N. (2007). Interfacial titanium oxide between hydroxyapatite and TiAlFe substrate. Journal of Materials Science: Materials in Medicine, 18(12), 2347-2354. doi:10.1007/s10856-007-3135-1M.S. Tkachev, E.S. Melnikov, M.A. Surmeneva, A.A. Sharonova, R.A. Surmenev, O.S. Korneva, I.A. Shulepov, K. Loza, M. Epple, Adhesion properties of a three-layer system based on RF-magnetron sputter deposited calcium-phosphate coating and silver nanoparticles, Proc. - 2016 11th Int. Forum Strateg. Technol. IFOST 2016. (2017) 88–90. doi:https://doi.org/10.1109/IFOST.2016.7884197.E. Mohseni, E. Zalnezhad, a. R. Bushroa, Comparative investigation on the adhesion of hydroxyapatite coating on Ti-6Al-4V implant: A review paper, Int. J. Adhes. Adhes. 48 (2014) 238–257. doi:https://doi.org/10.1016/j.ijadhadh.2013.09.030.Sargeant, A., & Goswami, T. (2007). Hip implants – Paper VI – Ion concentrations. Materials & Design, 28(1), 155-171. doi:10.1016/j.matdes.2005.05.018Qi, J., Yang, Y., Zhou, M., Chen, Z., & Chen, K. (2019). Effect of transition layer on the performance of hydroxyapatite/titanium nitride coating developed on Ti-6Al-4V alloy by magnetron sputtering. Ceramics International, 45(4), 4863-4869. doi:10.1016/j.ceramint.2018.11.183Ghasemi, S., Shanaghi, A., & Chu, P. K. (2017). Nano mechanical and wear properties of multi-layer Ti/TiN coatings deposited on Al 7075 by high-vacuum magnetron sputtering. Thin Solid Films, 638, 96-104. doi:10.1016/j.tsf.2017.07.049Thian, E. S., Huang, J., Barber, Z. H., Best, S. M., & Bonfield, W. (2011). Surface modification of magnetron-sputtered hydroxyapatite thin films via silicon substitution for orthopaedic and dental applications. Surface and Coatings Technology, 205(11), 3472-3477. doi:10.1016/j.surfcoat.2010.12.012Vladescu, A., Birlik, I., Braic, V., Toparli, M., Celik, E., & Ak Azem, F. (2014). Enhancement of the mechanical properties of hydroxyapatite by SiC addition. Journal of the Mechanical Behavior of Biomedical Materials, 40, 362-368. doi:10.1016/j.jmbbm.2014.08.025Azem, F. A., Kiss, A., Birlik, I., Braic, V., Luculescu, C., & Vladescu, A. (2014). The corrosion and bioactivity behavior of SiC doped hydroxyapatite for dental applications. Ceramics International, 40(10), 15881-15887. doi:10.1016/j.ceramint.2014.07.116Ciobanu, C. S., Iconaru, S. L., Le Coustumer, P., Constantin, L. V., & Predoi, D. (2012). Antibacterial activity of silver-doped hydroxyapatite nanoparticles against gram-positive and gram-negative bacteria. Nanoscale Research Letters, 7(1). doi:10.1186/1556-276x-7-324Peetsch, A., Greulich, C., Braun, D., Stroetges, C., Rehage, H., Siebers, B., … Epple, M. (2013). Silver-doped calcium phosphate nanoparticles: Synthesis, characterization, and toxic effects toward mammalian and prokaryotic cells. Colloids and Surfaces B: Biointerfaces, 102, 724-729. doi:10.1016/j.colsurfb.2012.09.040A. Quirama, A.M. Echavarría, J.M. Meza, J. Osorio, G. Bejarano G, Improvement of the mechanical behavior of the calcium phosphate coatings deposited onto Ti6Al4V alloy using an intermediate TiN/TiO2 bilayer, Vacuum. 146 (2017) 22–30. doi:https://doi.org/10.1016/j.vacuum.2017.09.024.Lenis, J. A., Hurtado, F. M., Gómez, M. A., & Bolívar, F. J. (2019). Effect of thermal treatment on structure, phase and mechanical properties of hydroxyapatite thin films grown by RF magnetron sputtering. Thin Solid Films, 669, 571-578. doi:10.1016/j.tsf.2018.11.045Sofronia, A. M., Baies, R., Anghel, E. M., Marinescu, C. A., & Tanasescu, S. (2014). Thermal and structural characterization of synthetic and natural nanocrystalline hydroxyapatite. Materials Science and Engineering: C, 43, 153-163. doi:10.1016/j.msec.2014.07.023Shiri, S., Ashtijoo, P., Odeshi, A., & Yang, Q. (2016). Evaluation of Stoney equation for determining the internal stress of DLC thin films using an optical profiler. Surface and Coatings Technology, 308, 98-100. doi:10.1016/j.surfcoat.2016.07.098Barry, J. N., Cowley, A., McNally, P. J., & Dowling, D. P. (2013). Influence of substrate metal alloy type on the properties of hydroxyapatite coatings deposited using a novel ambient temperature deposition technique. Journal of Biomedical Materials Research Part A, 102(3), 871-879. doi:10.1002/jbm.a.34755Constable, C. P., Yarwood, J., & Münz, W.-D. (1999). Raman microscopic studies of PVD hard coatings. Surface and Coatings Technology, 116-119, 155-159. doi:10.1016/s0257-8972(99)00072-9Cuscó, R., Guitián, F., Aza, S. d., & Artús, L. (1998). Differentiation between hydroxyapatite and β-tricalcium phosphate by means of μ-Raman spectroscopy. Journal of the European Ceramic Society, 18(9), 1301-1305. doi:10.1016/s0955-2219(98)00057-0Ivanova, A. A., Surmeneva, M. A., Grubova, I. Y., Sharonova, A. A., Pichugin, V. F., Chaikina, M. V., … Surmenev, R. A. (2013). Influence of the substrate bias on the stoichiometry and structure of RF-magnetron sputter-deposited silver-containing calcium phosphate coatings. Materialwissenschaft und Werkstofftechnik, 44(2-3), 218-225. doi:10.1002/mawe.201300101Yonggang, Y., Wolke, J. G. C., Yubao, L., & Jansen, J. A. (2007). The influence of discharge power and heat treatment on calcium phosphate coatings prepared by RF magnetron sputtering deposition. Journal of Materials Science: Materials in Medicine, 18(6), 1061-1069. doi:10.1007/s10856-007-0119-0Xin, R., Leng, Y., Chen, J., & Zhang, Q. (2005). A comparative study of calcium phosphate formation on bioceramics in vitro and in vivo. Biomaterials, 26(33), 6477-6486. doi:10.1016/j.biomaterials.2005.04.028Surmeneva, M. A., Tyurin, A. I., Mukhametkaliyev, T. M., Pirozhkova, T. S., Shuvarin, I. A., Syrtanov, M. S., & Surmenev, R. A. (2015). Enhancement of the mechanical properties of AZ31 magnesium alloy via nanostructured hydroxyapatite thin films fabricated via radio-frequency magnetron sputtering. Journal of the Mechanical Behavior of Biomedical Materials, 46, 127-136. doi:10.1016/j.jmbbm.2015.02.025M.A. Surmeneva, M. V. Chaikina, V.I. Zaikovskiy, V.F. Pichugin, V. Buck, O. Prymak, M. Epple, R. a. Surmenev, The structure of an rf-magnetron sputter-deposited silicate-containinghydroxyapatite-based coating investigated by high-resolution techniques, Surf. Coatings Technol. 218 (2013) 39–46. doi:https://doi.org/10.1016/j.surfcoat.2012.12.023.A. Ivanova, M.A. Surmeneva, A.I. Tyurin, T.S. Pirozhkova, I.A. Shuvarin, O. Prymak, M. Epple, M. V Chaikina, R.A. Surmenev, Applied Surface Science Fabrication and physico-mechanical properties of thin magnetron sputter deposited silver-containing hydroxyapatite films, 360 (2016) 929–935.Ding, S.-J., Ju, C.-P., & Lin, J.-H. C. (1999). Characterization of hydroxyapatite and titanium coatings sputtered on Ti-6Al-4V substrate. Journal of Biomedical Materials Research, 44(3), 266-279. doi:10.1002/(sici)1097-4636(19990305)44:33.0.co;2-4A.R.A. Sagari, Ca-P-O thin film preparation, modification and characterisation, Ph.D thesis, University of Jyväskylä, 2011. https://jyx.jyu.fi/bitstream/handle/123456789/37195/Arcot_Rajashekar-Ananda-2011.pdf?sequence=1.Paital, S. R., & Dahotre, N. B. (2009). Calcium phosphate coatings for bio-implant applications: Materials, performance factors, and methodologies. Materials Science and Engineering: R: Reports, 66(1-3), 1-70. doi:10.1016/j.mser.2009.05.001Deligianni, D. (2001). Effect of surface roughness of the titanium alloy Ti–6Al–4V on human bone marrow cell response and on protein adsorption. Biomaterials, 22(11), 1241-1251. doi:10.1016/s0142-9612(00)00274-xEchavarría, A. M., Rico, P., Gómez Ribelles, J. L., Pacha-Olivenza, M. A., Fernández-Calderón, M.-C., & Bejarano-G, G. (2017). Development of a Ta/TaN/TaNx(Ag)y/TaN nanocomposite coating system and bio-response study for biomedical applications. Vacuum, 145, 55-67. doi:10.1016/j.vacuum.2017.08.020García, C. G., Ferrus, L. L., Moratal, D., Pradas, M. M., & Sánchez, M. S. (2009). Poly(L-lactide) Substrates with Tailored Surface Chemistry by Plasma Copolymerisation of Acrylic Monomers. Plasma Processes and Polymers, 6(3), 190-198. doi:10.1002/ppap.200800112Perdok, W. G., Christoffersen, J., & Arends, J. (1987). The thermal lattice expansion of calcium hydroxyapatite. Journal of Crystal Growth, 80(1), 149-154. doi:10.1016/0022-0248(87)90534-3Evans, A. G., Crumley, G. B., & Demaray, R. E. (1983). On the mechanical behavior of brittle coatings and layers. Oxidation of Metals, 20(5-6), 193-216. doi:10.1007/bf00656841ASTM C1624-05, Standard Test Method for Adhesion Strength and Mechanical Failure Modes of, Astm. 05 (2015) 1–29. doi:https://doi.org/10.1520/C1624-05R15.Scope.Yang, Y. ., & Chang, E. (2001). Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti–6Al–4V substrate. Biomaterials, 22(13), 1827-1836. doi:10.1016/s0142-9612(00)00364-1Lenis, J. A., Toro, L. J., & Bolívar, F. J. (2019). Multi-layer bactericidal silver - calcium phosphate coatings obtained by RF magnetron sputtering. Surface and Coatings Technology, 367, 203-211. doi:10.1016/j.surfcoat.2019.03.03

    Using screen video capture software to aide and inform cognitive interviewing

    Get PDF
    Web-based surveys are a salient tool in the repertoire of social and behavioral scientists. The increase in web-based surveys is understandable considering the distinct advantages offered, including: (a) lower costs and reduced labor time, (b) ability to directly transfer data into statistical packages (reducing coding errors), (c) customization options enabling more attractive presentation, (d) ability to reduce respondent burden by embedding skip patterns, and (e) access to larger sample sizes in different geographic regions. It is important to note, however, that administering web-based surveys also introduces distinct sources of error (e.g., coverage, sampling and non-response). Regardless of format (e.g., paper-and-pencil or web-based), specific, prescribed steps must be followed when constructing an instrument in order to reduce survey error and lend credence to the data collected before subsequent analysis is performed. One of those crucial stages integral to the pretesting process is cognitive interviewing. Cognitive interviewing is a qualitative process, encompassing two main techniques: think aloud interviewing and verbal probing. Collectively, these two methods seek to (a) produce information on what the respondent is thinking while answering the questions, (b) the cognitive processes used to answer the questions, and (c) how the respondent answers the questions. The purpose of this article is to provide a practical guide outlining how Camtasia, a screen video capture software, can aide and inform the cognitive interview process

    Conducting a team-based multi-sited focused ethnography in primary care

    Get PDF
    © 2017 The Author(s). Focused ethnography is an applied and pragmatic form of ethnography that explores a specific social phenomenon as it occurs in everyday life. Based on the literature a problem-focused research question is formulated before the data collection. The data generation process targets key informants and situations so that relevant results on the pre-defined topic can be obtained within a relatively short time-span. As part of a theory based evaluation of alternative forms of consultation (such as video, phone and email) in primary care we used the focused ethnographic method in a multisite study in general practice across the UK. To date there is a gap in the literature on using focused ethnography in healthcare research. The aim of the paper is to build on the various methodological approaches in health services research by presenting the challenges and benefits we encountered whilst conducing a focused ethnography in British primary care. Our considerations are clustered under three headings: constructing a shared understanding, dividing the tasks within the team, and the functioning of the focused ethnographers within the broader multi-disciplinary team. As a result of using this approach we experienced several advantages, like the ability to collect focused data in several settings simultaneously within in a short time-span. Also, the sharing of experiences and interpretations between the researchers contributed to a more holistic understanding of the research topic. However, mechanisms need to be in place to facilitate and synthesise the observations, guide the analysis, and to ensure that all researchers feel engaged. Reflection, trust and flexibility among the team members were crucial to successfully adopt a team focused ethnographic approach. When used for policy focussed applied healthcare research a team-based multi-sited focused ethnography can uncover practices and understandings that would not be apparent through surveys or interviews alone. If conducted with care, it can provide timely findings within the fast moving context of healthcare policy and research
    corecore